background image

 
 
 
 
 

Installation Guide Index 

 
 

Section 

 

 

1. 

System 

Description 

    (page 

2) 

 

2. 

System 

Operation 

    (page 

2) 

 

3. Detector Positioning 

 

 

 

 

(page 2 to 4) 

 

4. 

Installation 

     (page 

5) 

 

5. 

Prism 

Targeting 

    (page 

5) 

 

6. 

Alignment 

     (page 

to 

7) 

 

7. 

System 

Testing 

    (page 

7) 

 

8.  Connection and configuration Settings   

(page 8) 

 

9.  Detector Back View  

 

 

 

(page 9) 

 

10. 

Address 

settings 

    (page 

10) 

 

11. 

Clearances 

     (page 

11) 

 

12. 

Technical 

Data 

    (page 

11) 

 

13. 

Service/Application 

Notes 

   (page 

12) 

 

14. 

Parts 

List 

     (page 

12) 

 

15. 

Remarks 

     (page 

12) 

 

 
 
 
 
 

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание ZP7BMR-50

Страница 1: ...Range 50 100 Metres Unique simple alignment Loop powered Selectable alarm thresholds Low current consumption Automatic contamination compensation ZITON ZP7BMR 50 100 Loop Powered Analogue Addressable...

Страница 2: ...ism Targeting page 5 6 Alignment page 5 to 7 7 System Testing page 7 8 Connection and configuration Settings page 8 9 Detector Back View page 9 10 Address settings page 10 11 Clearances page 11 12 Tec...

Страница 3: ...ondition being rectified The Detector monitors long term degradation of signal strength caused by component ageing or build up of dirt on optical surfaces This operates by comparing the received infra...

Страница 4: ...creased from 7 5 metres either side of the beam to 7 5 7 5 x 20 100 metres 9 metres Therefore with a roof pitch of 20 degrees the lateral coverage can be increased from 7 5 metres either side of the b...

Страница 5: ...ON OFF ON OFF ON X Logic 1 0 1 0 1 0 1 X The Detector Head Assembly is now ready for installation If configuration switches 3 and 4 require resetting after installation a power down reset is required...

Страница 6: ...horizontal and vertical thumbwheels until the Amber LED is flashing Both the Red and Amber LED will be OFF when no signal is being received The Red LED will start to flash when a weak signal is receiv...

Страница 7: ...be receiving a fringe reflection from another object FLICKERING RED AMBER This state can occur sometimes It means that the infrared power is stepping through the optimum setting for the current orient...

Страница 8: ...n filter to correspond with the Detector alarm threshold see fig 3 Place the filter over the receiver optics Top of Detector Head opposite end to the status indication LED s at the correct obscuration...

Страница 9: ...itch with the following features The address settings is set up via the 8 way DIP switch on the lower part of the beam See Fig 4 8 3 Typical Loop Wiring Fire Panel Connections Loop Output Input to Nex...

Страница 10: ...9 Detector Interface Assembly Configuration Settings DIP SWITCH SETTINGS X X X X X X X X X X X X X X X X X X X 2 X 1 3 4 Fig 4 www acornfiresecurity com www acornfiresecurity com...

Страница 11: ...0001011X 19 1100100X 62 0111110X 105 1001011X 20 0010100X 63 1111110X 106 0101011X 21 1010100X 64 0000001X 107 1101011X 22 0110100X 65 1000001X 108 0011011X 23 1110100X 66 0100001X 109 1011011X 24 000...

Страница 12: ...ameter clearance down the entire beam path If there are highly reflective objects within 1 metre diameter of the beam path for the first 20 metres of the beam path for the ZP7BMR 100R then tests shoul...

Страница 13: ...rt 5 use 25 and 35 default thresholds The threshold of 50 is recommended for hostile and extreme environments When in normal run mode the fire panel controls the Red LED flashing Amber LED flashing on...

Отзывы: