INSTALLATION / FIRST START-UP
SETTING UP AND INSTALLATION
Important instructions for setting up the system
The Zirkonofen 700 & 700 Ultra-Vakuum sintering furnaces have to be operated under the
following conditions only:
- Up to 2,000 m above sea level.
- Ambient temperature, in the range from 15 °C to 30 °C.
- Do not expose the system to direct solar radiation.
- Maximum relative air humidity of 75 % at 30 °C.
- Do not place it near an air conditioner. Avoid cold draughts.
- The Zirkonofen 700 & 700 Ultra-Vakuum sintering furnaces have to be moved and put down
on surfaces with suitable stability, in a dry place and in a non-corrosive environment.
- Stable, non-slip installation surface, which can bear a minimum weight of 300 kg.
- Safety distance of min. 2 m to combustible material.
- Safety distance of min. 2 m to water.
- Safety distance of min. 1.5 m to all sides (for cooling air, access).
-
2NCEGVJGVCDNGQPCƀCVITQWPFCPFCNKIPVJGYQTMUWTHCEGJQTK\QPVCNN[
- Provide for adequate work height (consider the height of the front glass in raised position).
- Work and danger area must be easily visible and lit (at least 500 lux).
- Make sure that the set position of the sintering furnace during operation allows easy removal of
the power plug in case of emergency.
-
#PGNGEVTKECNUQEMGVYKVJCRQYGTQWVRWVQH8KUTGSWKTGFCUſZGFEQPPGEVKQP.C[
connection cable protected with strain relief. The electrical socket and mains fuse must be set
up according to the valid national standards. The functioning of grounding and the protective
conductor must be checked before starting.
-
6JGRQYGTUWRRN[OWUVDGEQPUVCPV8QNVCIGƀWEVWCVKQPUOKIJVFCOCIGVJGGSWKROGPVŏU
components.
- Power supply must be installed and attached by an expert.
The equipment must be easily accessible from all sides for operation and component exchange.
- The system must not be connected to the electric circuit during the installation phase:
danger of electric shock.
- No objects must be placed on top of or beside the Zirkonofen 700 & 700 Ultra-Vakuum
UKPVGTKPIHWTPCEGUſTGJC\CTF
Содержание ZIRKONOFEN 700
Страница 1: ...Zirkonofen 7oo 7oo Ultra vakuum operator s and maintenance manual ...
Страница 3: ...03 03 ...
Страница 7: ...07 07 ...
Страница 10: ...10 10 ...
Страница 18: ...18 18 CHAPTERL SAFETY RESIDUAL RISKS ...
Страница 19: ...19 19 CHAPTER 2 COMPONENTS COMPONENTS ...
Страница 28: ...28 28 CHAPTERL 5 OPERATION ...
Страница 30: ...30 30 CHAPTERL 6 SINTERING PROGRAMMES ...
Страница 33: ...33 33 CHAPTER 7 CLEANING AND MAINTENANCE ...
Страница 34: ...34 34 CHAPTERL 7 CLEANING AND MAINTENANCE ...
Страница 43: ...43 43 ...