background image

This tool is designed to help locate a through-hole point 

for drilling through walls. It operates in one of two modes:

• Normal Scan 

is optimized for interior walls with  

1

2

" (1.3 cm) sheetrock on both sides, up to 4.5

(11.5 cm) thick

• DeepScan 

is for use with thicker walls, up to         

11.8

"

 (30 cm)

Depth can vary due to wall material and construction.

INSTALLING THE BATTERIES

Before first use, remove the PULL tab in the  

battery compartment.

Always use new alkaline AAA (LR03) batteries with 

extended expiration dates at least 3 years beyond the 

current date. Match the direction of batteries to the images 

inside of battery cavity.

Low battery:

 When the battery level is too low for proper 

operation, the Receiver will automatically power off.  

If Receiver does not light upon pressing the Power / MODE 

Button, please replace all three batteries with a brand   

new set.

POWER UP

To activate Receiver, hold the tool flat against the 

surface being scanned and press the Power / MODE 

Button. 

Lights will flash as tool automatically calibrates, 

then a beep will sound and a blue light will hold steady 

once calibration is complete.
A failed calibration is indicated by a rapid pulsing of both 

red and blue LEDs at the same time. Move the Receiver 

away from the suspected location of the Target Magnet 

and it will automatically recalibrate.

POWER DOWN

To power off the Receiver, press and hold the 

Power / MODE Button down for approximately  

2 seconds.

 Lights will turn off.

The Receiver will automatically power off approximately  

3 minutes after last calibration.

USE DEEPSCAN MODE

Use DeepScan Mode for scanning through 

materials more than 4.5

"

 (11.5 cm) but 

less than 11.8

"

 (30 cm) thick.

For DeepScan, always use the Large  

Target Magnet. (

Figure F

)

1. 

Determine where the drill exit hole 

should be. Affix the Large Target Magnet 

to the location with a reusable adhesive disc,  

yellow side facing away from wall.  

2. 

Power up Receiver, then press Power / MODE 

Button twice to switch from Normal to  

DeepScan Mode. The DeepScan Mode Indicator 

light will illuminate as indicated by icon to the right.

3. 

Follow steps 4–8 under SCAN IN NORMAL  

SCAN MODE.

STORING REUSABLE ADHESIVE DISCS

This tool comes with 9 double-sided, reusable  

adhesive discs. With repetitive use or exposure to  

dust particles, discs may lose stickiness. Gently wash  

with soapy water, rinse, air dry, and reuse.
The discs can be stored within the battery compartment  

by stacking within the designated, circular template. 

To order more, email [email protected]

SCAN IN NORMAL SCAN MODE

The Receiver powers up in Normal Scan 

Mode, indicated by the Normal Scan 

Mode Indicator light. Always use the 

Small Target Magnet when scanning in 

this mode. (

Figure A

)

Use Normal Scan Mode for scanning 

through materials up to 4.5

"

 (11.5 cm) thick.

WARNING

DO NOT ASSUME THERE ARE NO  

LIVE ELECTRICAL WIRES IN  

THE WALL. DO NOT TAKE ACTIONS THAT COULD  

BE DANGEROUS IF THE WALL CONTAINS A LIVE 

ELECTRICAL WIRE. ALWAYS TURN OFF THE 

ELECTRICAL, GAS, AND WATER SUPPLIES BEFORE 

PENETRATING A SURFACE. FAILURE TO FOLLOW 

THESE INSTRUCTIONS MAY RESULT IN ELECTRIC 

SHOCK, FIRE, AND/OR SERIOUS INJURY OR 

PROPERTY DAMAGE.

1. 

Determine where the drill exit hole should be.  

Clean the surface of any dust or oils, and make sure  

the surface is dry. 

2. 

Remove the protective plastic 

from both sides of an adhesive disc, 

then use the disc to affix the  

Small Target Magnet to the location, 

with yellow side facing away  

from wall. (

Figure B

3. 

Grasp grips with thumb on one 

and fingers on the other. 

Place the 

Receiver flat against the opposite 

surface from the Target Magnet,  

but in an area not likely to be  

over it.  

4. 

Power up the Receiver and let it 

calibrate until the blue light is steady 

(not flashing). 

5. 

Move the Receiver horizontally. 

As it approaches the target, red LEDs 

will flash slowly. When the red lights 

go steady, mark the location through 

the reticle groove. (

Figure C

)

6. 

Continue scanning in the same 

direction until the red and blue LEDs 

flash, then reverse direction.

7. 

Mark the location where the red 

LED shines steadily. The approximate 

midpoint of the target is between the 

two marks. (

Figure D

)

8. 

Without recalibrating, move the 

Receiver to the midpoint, then scan 

vertically until the top and bottom 

limits are marked. The center of the Target  

Magnet should be the midpoint between  

the top and bottom marks. (

Figure E

)

WARNING

This Receiver does NOT detect hidden 

objects behind surface. Use other 

information sources to locate, and avoid, objects 

behind surface before drilling.

LIMITED 1 YEAR WARRANTY
Zircon Corporation (“Zircon”) warrants to the product 

owner that this product will be free from defects in 

materials and workmanship for one year from the 

original date of purchase. Any defective product 

returned to Zircon within the warranty period to the 

address below, freight prepaid, along with proof of 

purchase, will be repaired or replaced, at Zircon’s 

option. Repair or replacement may be made with a 

new or refurbished product or components, at Zircon’s 

sole discretion. If the returned product is no longer 

available, Zircon may replace the product with a 

similar product of similar function. This warranty is 

limited to the electronic circuitry of the product and 

original case of the product, and specifically excludes 

any damage caused by abuse, modification, handling 

contrary to these instructions, other unreasonable use, 

or neglect. This is your sole and exclusive remedy for 

breach of this Limited Warranty.
This Limited Warranty is in lieu of all other warranties, 

express or implied, and no other representations or 

claims of a similar nature will bind or obligate Zircon. 

Any implied warranties applicable to this product 

that cannot be disclaimed are limited to the one year 

period following its purchase. This Limited Warranty 

does not cover consumable parts, including batteries, 

or software, even if packaged with the product.  

IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY 

SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES 

RESULTING FROM POSSESSION, USE OR MALFUNCTION 

OF THIS PRODUCT.
Some states do not allow limitations on certain 

implied warranties and/or the limitation on incidental 

or consequential damages, so the above limitations 

and exclusions may not apply to you. This warranty 

gives you specific legal rights, and you may also have 

other rights which vary from state to state. 
Return products for warranty service, freight prepaid 

with proof of purchase (a dated sales receipt) to:
Zircon Corporation 

Attn: Returns Department 

1580 Dell Avenue 

Campbell, CA 95008-6992 USA
Be sure to include your name and return address.  

Allow 4–6 weeks for delivery. 
Customer Service: 1-800-245-9265 or 1-408-963-4550 

Monday–Friday, 8:00 a.m.–5:00 p.m. PT 

[email protected] • www.zircon.com
©2018 Zircon Corporation • P/N 67056 • Rev G 11/18 
DeepScan, ExitPoint and Zircon are registered 

trademarks or trademarks of Zircon Corporation.

BEFORE YOU BEGIN

THIS TOOL WORKS BY DETECTING A HIGH-POWERED MAGNET ON THE OTHER SIDE OF A WALL. IT DOES NOT DETECT 

STUDS, PIPES, OR ELECTRICAL WIRES. 

USE OTHER TOOLS TO DETECT STUDS, PIPES OR ELECTRICAL WIRES 

BEFORE DRILLING.

- Always use new alkaline AAA (LR03) batteries with extended expiration dates at least 3 years beyond the current date. 

Match the direction of batteries to the images inside of battery cavity.
- Before drilling, use a Zircon stud finding scanner to scan for studs at several different heights on the wall and mark the 

location of every target indicated by the stud finder. This is called “mapping the wall.” Pipes and other objects will likely 

not give consistent readings from floor to ceiling like a stud would.
- Readings should always be consistent and repeatable.
- Studs normally run from floor to ceiling, except above and below windows, and above doors.
- Other objects commonly contained in walls, floors, or ceilings are water pipes, gas lines, firestops, and electrical wiring.
- Sensing depth and accuracy can vary depending on scanning environment conditions such as mineral content, moisture, 

texture and consistency of the wall materials.
- Always turn off power when working near electrical wires.
- Caution should always be used when nailing, cutting, or drilling in walls, floors, and ceilings that may  

contain these items.
- Studs and joists are normally spaced 16 or 24" (40 or 60 cm) apart, are normally 1

1

2

" (38 mm) wide, and may be 

separated by firestops. Anything closer together, or of a different width, may not be a stud or joist.
- Materials more than 11.8" (30 cm) thick may not be detected.
- Keep away from children, pacemakers, and medical devices.
- Fingers can get severely pinched between two attracting magnets.
- Do not dismantle magnet housings. Magnets can peel, crack, or shatter if allowed to slam together.
- Do not expose to magnetic media and other electronics. The strong magnetic fields can damage these items.
- Keep magnets away from heat and fire.

ExitPoint

®

 

 

XL300

Through-Hole Drill Guide

EN

Visit www.zircon.com for the 

most current instructions.

FCC Part 15 Class B Registration Warning: This device complies  

with Part 15 of FCC Rules. Operation is subject to the following  

two conditions: (1) this device may not cause harmful interference, 

and (2) this device must accept any interference received, including 

interference that may cause undesired operation.

ZirconCorporation

ZirconTV

ZirconTools

 | 

ZirconToolPro

ZirconTools

TROUBLESHOOTING & CONSTRUCTION TIPS

SITUATION

LIKELY CAUSE

SOLUTION

• Receiver does not power on or 

powers off immediately.
• Receiver keeps recalibrating or 

indicating calibration error.

Battery PULL Tab not removed.

Remove PULL Tab from battery compartment.

Battery level too low for proper 

operation.

Replace with (3) brand new alkaline AAA batteries.

Solid red indication flickers (blue LEDs 

momentarily turn on) when Receiver is 

believed to be over Target Magnet.

Receiver needs to be recalibrated. Move Receiver away from suspected target location, recalibrate,  

then restart search for Target Magnet.

Solid red indication continues to flicker 

after several recalibration attempts.

Receiver is unable to locate Target 

Magnet in this particular location.

Change to DeepScan

®

 Mode (Large Target Magnet) and rescan for 

Target Magnet.

Unable to locate Target Magnet.

Target Magnet is oriented the 

wrong direction (north pole).

Orient Target Magnet in other direction (south pole).

Receiver is within approximately 

1" (25 mm) of Target Magnet.

If the Receiver is too close to the Target Magnet, the magnetic lines 

wrap around magnet. Move Receiver further away from Target Magnet 

and rescan.

Target Magnet distance exceeds 

scan mode specifications.

Check scan depth, Target Magnet size, and scan mode.

Figure A

Figure F

DISPLAY INDICATIONS

DISPLAY

INDICATES

Single triangle illuminated. 

Receiver is in Normal Scan Mode. Use Small Target Magnet.

Double triangle illuminated.  

Receiver is in DeepScan Mode. Use Large Target Magnet.

Red and blue LEDs flash in a circular motion.

Receiver is calibrating. Wait for it to finish before moving.

Blue LEDs on (steady), red LEDs off. A short beep sounds. 

Calibration is complete. Receiver is ready to scan.

Blue LEDs on (steady), while red LEDs flash.

• Target Magnet detected but not yet located.
• Detection of stray magnetic fields in DeepScan Mode.
• Red LEDs flash more rapidly as Receiver approaches Target Magnet.  

They flash more slowly as it moves away.

Red LEDs on (steady) / Blue LEDs off.

Magnetic field strength is very strong.

Both blue and red LEDs flash.

Calibration failed. Recalibrate again.

STORING YOUR TOOL

• Padded pouch holds and protects scanner
• Before storing, use a dry cloth to clean all parts.  

Do not expose the tool to liquid

• Pouch flap securely closes
• D-rings on end of flap and bottom of pouch can be  

used to lock pouch

• Clear front pocket holds ID for company or individual
• Hook and loop straps on back can be used as a  

shoulder strap, strapped around waist, or hung from  

belt loops

• D-ring on back can be used to hang pouch when  

not in use

• Exterior elastic loops conveniently hold pencils,  

pens or small tools

• Interior elastic loops can hold 3 AAA batteries  

Battery Door Tab 

(door on bottom)

LED Indicators

Reticle (target crosshairs) Groove

Normal Scan Mode Indicator
DeepScan

®

 Mode Indicator

Power / MODE Button

Small Target Magnet  

(for Normal Scan)

Large Target Magnet 

(for DeepScan)

NOT SHOWN:

• 3 AAA (LR03) batteries

• 9 reusable adhesive discs

• Padded pouch for storage 

and carrying

Grip Area

Figure B

Figure C

Figure D

Figure E

Receiver

Содержание ExitPoint XL300

Страница 1: ...ay from heat and fire ExitPoint XL300 Through Hole Drill Guide EN TROUBLESHOOTING CONSTRUCTION TIPS SITUATION LIKELY CAUSE SOLUTION Receiver does not power on or powers off immediately Receiver keeps recalibrating or indicating calibration error Battery PULL Tab not removed Remove PULL Tab from battery compartment Battery level too low for proper operation Replace with 3 brand new alkaline AAA bat...

Страница 2: ... a brand new set POWER UP To activate Receiver hold the tool flat against the surface being scanned and press the Power MODE Button Lights will flash as tool automatically calibrates then a beep will sound and a blue light will hold steady once calibration is complete A failed calibration is indicated by a rapid pulsing of both red and blue LEDs at the same time Move the Receiver away from the sus...

Страница 3: ... from wall Figure B 3 Grasp grips with thumb on one and fingers on the other Place the Receiver flat against the opposite surface from the Target Magnet but in an area not likely to be over it 4 Power up the Receiver and let it calibrate until the blue light is steady not flashing 5 Move the Receiver horizontally As it approaches the target red LEDs will flash slowly When the red lights go steady ...

Страница 4: ...r MODE Button twice to switch from Normal to DeepScan Mode The DeepScan Mode Indicator light will illuminate as indicated by icon to the right 3 Follow steps 4 8 under SCAN IN NORMAL SCAN MODE STORING REUSABLE ADHESIVE DISCS This tool comes with 9 double sided reusable adhesive discs With repetitive use or exposure to dust particles discs may lose stickiness Gently wash with soapy water rinse air ...

Страница 5: ... flap and bottom of pouch can be used to lock pouch Clear front pocket holds ID for company or individual Hook and loop straps on back can be used as a shoulder strap strapped around waist or hung from belt loops D ring on back can be used to hang pouch when not in use Exterior elastic loops conveniently hold pencils pens or small tools Interior elastic loops can hold 3 AAA batteries ...

Страница 6: ...r nature will bind or obligate Zircon Any implied warranties applicable to this product that cannot be disclaimed are limited to the one year period following its purchase This Limited Warranty does not cover consumable parts including batteries or software even if packaged with the product IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM POSSESS...

Страница 7: ...plies with Part 15 of FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation ZirconCorporation ZirconTV ZirconTools ZirconToolPro ZirconTools ...

Отзывы: