Zippy Tech. R3G SERIES Скачать руководство пользователя страница 11

 

 

 

INPUT CHARACTERISTICS:   

 

 

                  R3G-6650P 

 

VOLTAGE: 90 ~ 264 VAC FULL RANGE 

 

FREQUENCY : 47 ~ 63 Hz 

 

INPUT CURRENT: 9.0 / 5.0 A FOR 115 / 230 VAC   

 

INRUSH CURRENT: 80A / 100A MAX. FOR 115 / 230 VAC PER POWER MODULE 

OUTPUT CHARACTERISTICS: 

OUTPUT CURRENT 

REGULATION 

OUTPUT 

 

MIN.[A] MAX.[A] PEAK(A)

LOAD 

LINE 

 

5V 

  3.0 

   60 

    

±

 5% 

±

 1% 

50mV 

12V 

      2 

      40 

       

±

 5% 

±

 1% 

100mV 

-5V 

    0.05 

      1 

       

±

10% 

±

 1% 

150mV 

-12V 

  0.05     1 

    

±

10% 

±

 1% 

150mV 

3.3V 

  1.0 

   40 

    

±

 5% 

±

 1% 

50mV 

+5VSB 

  0.1 

   2.5      

±

 5% 

±

 1% 

50mV 

OUTPUT 

VOLTAGE

 

RIPPLE & NOISE 

MAX. [P-P]

 

       

REMARKS: TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 70 A 

TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 630 W 

         

.

 

    TEMPERATURE RANGE : OPERATING 0

0

C --- 40

0

C, STORAGE –20

0

C --- 70

0

C

 

 

HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE 

 

DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE 

 

INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE 

 

EFFICIENCY: 63% TYPICAL, AT FULL LOAD 

 

POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms 

 

OVER LOAD PROTECTION: 110 ~ 160% MAX. 
OVER VOLTAGE PROTECTION:   
                               

+5V 

 5.7V ~ 6.7V, 3.3V 

 3.7 ~ 4.7V, 12V 

 13.0 ~ 15.0V 

.        SHORT CIRCUIT : 5V,12V, 3.3V, AUTO-RECOVERED : 5VSB, -5V, -12V   

 

EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B 

 

SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950 

 

 

REMOTE ON / OFF CONTROL 

 

FAULTY ALERT METHODS : LED, BUZZER, TTL SIGNAL   

 

2 + 1, HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION 

 

N + 1 BALANCE LOAD SHARING DESIGN ON 5/12/3.3V CHANNEL 

 

REMOTE SENSING DESIGN 

 

ISOLATION: BUILT-IN IN THE POWER MODULE 

 

MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )   

 

DIMENSION: 82(H) X 127(W) X 276/300 (D) mm, 276mm -- W/O REAR DC FAN 

 

COOLING : THREE 40 mm DC FANS ( ONE IN EACH MODULE ) 

 

                        ONE 80 mm DC FAN ( REAR SIDE ) 

 

Revision: A02 

Содержание R3G SERIES

Страница 1: ...PRODUCTS MANUAL R3G SERIES 2 1 Redundant Power Supply...

Страница 2: ...esignation page 2 1 4 Features page 3 1 5 Pre Installation page 3 1 6 Drawing page 4 8 1 7 Specification page 9 1 8 Installation Testing page 10 11 1 9 Hot Swap Procedures page 11 12 1 10 Pinouts and...

Страница 3: ...on the rear side of the whole system to make sure a safe working unit Each power module has designed with 6 outputs including 3 3V 5V 12V 12V 5V 5VSB circuits and higher current availability based on...

Страница 4: ...one holding bracket for shipment 1 C Products manual 1 1 3 MODEL DESIGNATION Model number identification R3G 6650P R3G 2 1 Redundant Power Supply for 3 U AC Input 6 for 6 DC outputs 5V 12V 5V 12V 3 3...

Страница 5: ...0W 350W output power Balance load sharing design Remote sensing design Meet FCC CISPR EMI regulation Smart I2 C interface design optional feature Space save click type handle design Three EMI Line Fil...

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ...DIELECTRIC WITHSTAND INPUT OUTPUT 1500 VAC FOR 1 MINUTE INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE EFFICIENCY 63 TYPICAL AT FULL LOAD POWER GOOD SIGNAL ON DELAY 100 ms TO 500 ms OFF DELAY 1 ms OVER L...

Страница 12: ...mote on the on off switch you will notice that if the power unit is operating properly then individual LEDs the total power warning LED please refer to Sec 1 10 for detail explanation are lit Green no...

Страница 13: ...Please perform the above step carefully otherwise it may cause shut down the whole system WARNING Please do not remove the defective power module until you have worn gloves to keep from be burned This...

Страница 14: ...w power module in simulating defective situation Please refer to the Section 1 8 Installation Testing Section 1 10 PINOUTS AND FUNCTION OF THE CONNECTORS Please be aware of the polarity THE BUZZER RES...

Страница 15: ...is under the minimum over the maximum load of each channel please refer the Sec 1 7 specification b If each power cord been well plugged into the inlet Suppose the above condition been happened pleas...

Страница 16: ...NJ 07936 TEL 1 973 463 9499 FAX 1 973 453 8014 E mail edward zippy com U S West Pacific 961 CALLE NEGOCIO SAN CLEMENTE CA 92673 USA TEL 1 949 366 9525 FAX 1 949 366 9526 EMAIL powerusa zippy com CANAD...