background image

User Manual for Models HG2, HP2, PSM and PSL.     

 

 

Version 1.0 

 

 
 

 

Page 15/17 

 

Operational Procedure

 

 

1.

 

When removing four attached screws to install this product, please make sure not removing fan or 
case screws by mistake. 

 

2.

 

Tighten  four  screws  onto  the  computer  case  and  double  check  for  stability.  (Please  refer  to  the 
figure on page 4). 

 
3.

 

Before connecting the units, make sure you verify connector and pin assignment for devices such 
as motherboard, hard disk etc. For example, the pin assignments of 24-pin and 8-pin connector on 
AMD Athlon MP Motherboard are totally different than Intel Xeon motherboard. Severe damages 
may occur by wrong connection.   

 

4.

 

Check product specifications and calculate actual current requirements of each DC voltage. Make 
sure  these  requirements  fall  within  the  minimum  and  maximum  range  of  power  supply.  If  the 
current requirements are below the minimum load spec., the power supply may not start up. If the 
current requirements are over the maximum load spec., our over protection circuitry will latch and 
shutdown the power supply. 

 
5.

 

Plug in power cord to the inlet of power supply. 

 

Only HG2 models have line power I/O rocker switch. Please set the switch to “I” or “ON” 
to turn on line power. For other models, just plug the power cord into the electrical outlet 
directly. 

 

Active  Power  Factor  Correction  (PFC)  function  is  available  for  all  power  supply  models 
listed  in  this  manual.  The  PFC  function  ensures  maximum  efficiency  of  power  usage  to 
preserve energy and lower your electrical bills. It also automatically adapts to a very wide 
range  of  AC  line  voltage:  100V  to  240V  AC.  (There  are  no  manual  switches  for  you  to 
select AC input). This unique design ensures you can use our power supplies anywhere in 
the world. 

 

6.

 

You can start up the power supply remotely by using “Remote on”.       

 
 

Содержание HG2

Страница 1: ...User Manual for Models HG2 HP2 PSM and PSL Version 1 0 Page 1 17 User Manual Product Type Switching Power Supply Model Name HG2 HP2 PSM PSL June 18 2003 Version 1 0 P N...

Страница 2: ...s HG2 HP2 PSM and PSL Version 1 0 Page 2 17 Table of Contents Safety and Warnings 3 Product and Accessories 4 Pin Assignment 5 Specification 8 Operational Procedures 12 Troubleshooting Maintenance 16...

Страница 3: ...vironment 6 Connect power supply only to designated power sources Do not place any other materials into the inlet of the power supply other than the power cord 7 Do not plug or unplug the power cord w...

Страница 4: ...computer remove those four screws first please do not remove fan or case screws All four screws should be installed and fasten 3 ATE Auto Testing Equipment report 4 User manual 5 Optional item AC pow...

Страница 5: ...D GND GND 5V 12V PS ON GND 24PINS EPS12V 1 13 12 11 10 8 9 7 5 6 4 3 2 24 23 22 21 20 19 17 18 16 15 14 OUTPUT NO PIN COLOR NO PIN COLOR OUTPUT RED 5V RED 5V RED 5V RED 5V BLACK GND BLACK GND BLACK GN...

Страница 6: ...COLOR PIN NO COLOR OUTPUT 12V 12V 12V OUTPUT PIN PIN GND GND COLOR BLACK BLACK NO 2 4 3 1 6 8 7 NO 5 COLOR YELLOW YELLOW YELLOW OUTPUT GND BLACK 5V RED PWR OK GREY OUTPUT PIN NO 1 2 BLACK BLACK GND G...

Страница 7: ...LLOW 2 1 4 3 BLACK RED OUTPUT COLOR NO PIN NO PIN COLOR 5V OUTPUT BLACK GND GND OUTPUT 12V GND COLOR BLACK YELLOW 2 1 NO PIN 4 3 NO PIN BLACK RED COLOR 5V OUTPUT 4PINS FLOPPY DISK 1 3 YELLOW 12V BLACK...

Страница 8: ...1 25 5 1 50m V 5VSB 0 1 2 5 1 50m V O UTPUT VO LTAG E RIPPLE NO ISE M AX P P REMARK THE OUTPUT CURRENT OF 5V 3 3V SHOULD NOT EXCEED 45A SPECIFICATION TEMPERATURE RANGE OPERATING 0 40 HOLD UP TIME 16 m...

Страница 9: ...T IT IS REQUESTED TO SET THE HIGHER OUTPUT CHANNEL AT 90 MAXIMUM AND THE LOWER OUTPUT CHANNELS AT 20 MININUM OF RATED SPEC TEMPERATURE RANGE OPERATING 0 0 C 40 0 C STORAGE 20 0 C 70 0 C HUMIDITY 10 90...

Страница 10: ...EQUESTED TO SET THE HIGHER OUTPUT CHANNEL AT 90 MAXIMUM AND THE LOWER OUTPUT CHANNELS AT 20 MININUM OF RATED SPEC TEMPERATURE RANGE OPERATING 0 0 C 40 0 C STORAGE 20 0 C 70 0 C HUMIDITY 10 90 RH HOLD...

Страница 11: ...TION TEST IT IS REQUESTED TO SET THE HIGHER OUTPUT CHANNEL AT 90 MAXIMUM AND THE LOWER OUTPUT CHANNELS AT 20 MININUM OF RATED SPEC TEMPERATURE RANGE OPERATING 0 0 C 40 0 C STORAGE 20 0 C 70 0 C HUMIDI...

Страница 12: ...mV 12V 2 52 60 60 5 1 120mV 5V 0 0 8 5 1 120mV 12V 0 0 8 5 2 120mV 3 3V 0 5 30 5 2 60mV 5VSB 0 3 5 5 1 60mV REMARK 1 TOTAL OUTPUT OF 5V AND 3 3V NOT EXCEED 230W 2 TOTAL MAX OUTPUT 720W 800W 850W SPECI...

Страница 13: ...MARKS 1 5V AND 3 3V TOTAL MAX POWER 170W 2 3 3V AND 5V AND 12V2 TOTAL MAX POWER 600W 3 TOTAL MAX POWER 1000W SPECIFICATION TEMPERATURE RANGE OPERATING 0 40 STORAGE TEMPERATURE 20 80 HOLD UP TIME 18mS...

Страница 14: ...EMARKS 1 5V AND 3 3V TOTAL MAX POWER 170W 2 3 3V AND 5V AND 12V2 TOTAL MAX POWER 600W 3 TOTAL MAX POWER 1200W SPECIFICATION TEMPERATURE RANGE OPERATING 0 40 STORAGE TEMPERATURE 20 80 HOLD UP TIME 18mS...

Страница 15: ...imum range of power supply If the current requirements are below the minimum load spec the power supply may not start up If the current requirements are over the maximum load spec our over protection...

Страница 16: ...n the power supply Reduce load or use larger capacity power supply There may be a system incompatibility or wrong connector pin out or connection when power supply its fan has spin for while then shut...

Страница 17: ...el on product and diagram below Product part number P N Product model Detailed description of problems Note Different distributors or resellers have their specific RMA terms and conditions please cont...

Отзывы: