background image

6

5

6

7

Содержание 44026

Страница 1: ...led in USA with domestic and foreign components 843712_rA ANSI Z21 72 2011 CSA 11 2 2011 MODEL 8202 54Z ZIPPO MODEL 44026 PLEASE RECORD YOUR SERIAL NUMBER LOCATED INSIDE LID OF WINDPROOF STOVE AND THE DATE OF PURCHASE BELOW SERIAL NUMBER ______________________________________________ DATE OF PURCHASE ___________________________________________ THIS INSTRUCTION MANUAL CONTAINS IMPORTANT INFORMATION...

Страница 2: ...2 ...

Страница 3: ...rdous amounts of CO if used and maintained in accordance with all warnings and instructions Do not block air flow into or out of the stove Carbon Monoxide CO poisoning produces flu like symptoms watery eyes headaches dizziness fatigue and possibly death You can t see it and you can t smell it It s an invisible killer If these symptoms are present during operation of this product get fresh air imme...

Страница 4: ...indicate a leak Check that the connection is not cross threaded and that it is tight Perform another leak check If there is still a leak remove the cylinder and contact Zippo Consumer Relations for service or repairs at 888 368 0826 Use as a cooking appliance only Never alter in any way or use with any device or part not expressly approved by Zippo Manufacturing Company Clean stove frequently to a...

Страница 5: ...5 4 2 3 2X 2X ...

Страница 6: ...6 5 6 7 ...

Страница 7: ...7 8 9 10 Free Standing Mode For Optional Leg Assembly ...

Страница 8: ...hand push the propane cylinder into the regulator and turn clockwise until tight Pull the quick connect coupler back until it clicks as shown in figure 3 2 Be sure appliance valves are shut off as shown in figure 4 3 With the propane cylinder assembled on the regulator and the quick connect coupler pulled back push the quick connect coupler onto the valve assembly until it clicks as shown in figur...

Страница 9: ...rotect the hose from dripping grease and do not allow the hose to touch any hot surface including the base casting of the windproof stove 5 Inspect seal in the QCC cylinder valve when replacing propane cylinder or once per year whichever is more frequent Replace seal if there is any indication of cracks creases or abrasion 6 Inspect hose before each use of the stove If the hose is cracked cut abra...

Страница 10: ...d Gas Cylinder Valve Outlet and Inlet Connection USA ANSI CSA V 1 1977 Canada CSA B96 The cylinder supply system must be arranged for vapor withdrawal The cylinder must include a collar to protect the cylinder valve The cylinder must be installed as per assembly instructions Never fill the cylinder beyond 80 full A fire causing death or serious injury may occur The cylinder valve must include a sa...

Страница 11: ... Zippo Consumer Relations at 888 368 0826 for assistance Do not attempt to operate appliance if a leak is present LIGHTING INSTRUCTIONS The lighting instructions are the same for both modes of usage and both propane supply configurations Before lighting The appliance must be assembled as per the assembly instructions Check that there is fuel in the propane cylinder and that it is properly connecte...

Страница 12: ...enance storage or transportation TO CLEAN 1 Move stove away from flame and other ignition sources 2 Remove propane cylinder and regulator from stove 3 Wipe surfaces clean with a damp soft cloth and a mild dish detergent DO NOT USE ABRASIVES 4 You can disassemble some components of the stove to assist in cleaning Burner Venturi Assembly KEEP BURNER VENTURI ASSEMBLY CLEAN Blockages caused by spiders...

Страница 13: ...ing tool 6 Replace the burner venturi assembly making sure that the burner venturi tube is correctly aligned with the screw holes and is aligned and fitted on the orifice 7 Install burner screws and reconnect ignitor wires to ignitor electrodes 8 Replace wind shields wire grate and lid figure 21 figure 22 figure 23 figure 24 figure 25 figure 26 ...

Страница 14: ...cts in burner venturi assembly are excluded REPLACEMENT PARTS Genuine Zippo Windproof Stove Parts must always be used for replacement Use of any other parts will automatically nullify the above warranty Contact Zippo Consumer Relations at 888 368 0826 for repairs or replacement parts To ensure optimum performance use only genuine Zippo Windproof Stove replacement parts BURNER VENTURI ASSEMBLY The ...

Страница 15: ...n electrode 4 Use Manual Lighting Procedure or replace 5 Tighten the regulator hand wheel 6 Close burner and cylinder valves Open cylinder valve slowly then open burner valve to light 7 Leak test connections to determine loose fitting Tighten fitting Leak test system 8 Remove burner clean burner venturi See Burner Venturi Assembly Section 9 Realign burner venturi to orifice See Burner Venturi Asse...

Страница 16: ...NTROL 2 15 10342 22 IGNITOR ALLUMAGE ENCENDEDOR 1 16 37430 178 LEG LEVELER SLEEVE MANCHON DE PIED NIVELURE MANGA DE LE PATA NIVELADOR 4 17 37420 178 LEG LEVELER INNER PIED NIVELEUR INTERIEURE PATA NIVELADORA INTERIOR 4 18 34100 904 LID PIN PINS COUVERCLE PINS DE TAPA 2 19 37409 241 BUBBLE LEVEL BUBBLE LEVELER BURBUJA LEVELER 1 20 32839 904 VALVE STRAP BANDE SOUPAPE VALVULA DE CORREA 1 21 10342 T14...

Отзывы: