Connecting devices
Before connecting a device on the AC socket you must control the perfect condi-
tion of the device.
When you recognise that a connected device acts unusual you must stop the
generator and disconnect the device. Control whether the device is damaged or
if the generator was overchallenged by the device.
ATTENTION: A short exceed of the normed power capacity of the generator is possi-
ble but if this happens oftener the life time of the generator will be shortened.
In exceptions the generator can be charged with the maximum power for max. 30
minutes.
The following list gives you a view about the differences of the electricity requirement
of some devices between start and continuous operation.
Verbrauchsart
Expenditure
of watt
Instance type of
device
Instance
Start During
opera-
tion
device
Start
During
operation
Electrical equip-
ment
X1
X1
100VA
100VA
Light
X1,5 X1
80VA
60VA
Devices with
engines
X
3~5
X2
450-
750VA
300VA
Please consider: Some devices, for instance cooling devices need up to 5 times more starting
current than current during the operation.
17.3
AC Operation
Connect the devices to the AC socket. The most devices need more energy (VA) for
starting than declared. A device with a normed power requirement of 1500 VA might
charge your generator up to its maximum for a short time.
.