OPERATION
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
30
ZI-STB16T
13.2
Operation
Switching ON:
•
Belt cover and spindle guard must be closed!
•
Release the EMERGENCY-switch (a) by turning clockwise.
•
Push the ON-button (b).
Switching OFF:
•
Push OFF-button (c).
•
In emergency the machine can be stopped by pushing the EMERGENCY-switch (a).
Drehzahl und Riemenspannung einstellen:
1.
Release the locking screw on the gear
cover with the allen key 5 mm.
2.
Pull the locking screw and open the
gear cover.
3.
Loosen the motor tension knob on each
side of the headstock.
4.
Slide the motor forward a little to
release the load on the V-belts. See
below illustration 2.
5.
Remove the V-belt between idle pulley
and motor pulley first, then slide idle
pulley towards the spindle pulley to
release the load on the V-belt between
idle pulley and spindle pulley. Remove
the second V-belt. See 2 & 3.
6.
Place the two V-belts on the desired
assembly to reach the specified speed.
(see table)
7.
Slide the motor back to tension the V-
belts again. The V-belts are correctly
tensioned when it gives way slightly
when pressed. Deflection distance of
belt is 5-10mm.
8.
Lock this position with the two motor
tension knobs.
9.
Close the gear cover. Fasten the
locking screw on the gear cover with
the allen key 5 mm.
As smaller the hole, as higher the rotation speed.
To achieve a good result is also:
Soft material => high rotation speed
Hard material => low rotation speed
a
b
c