Remaining risk factors
Despite of correct and proper use and maintenance there remain some residual risk factors:
•
Hazard of injury or machine damage due to undetected machine defect
To minimize this risk, check the machine prior to every operation for loose screws and
connections. Check the motor noise, the collector tubes, filter bag, dust collector bag and
impeller for eventual damage. Damaged parts have to be replaced immediately, no operation
of the machine in the meantime!
•
Hazard of electric shock
Undetected malfunctions in the power supply and/or the connected wood working machine
might result in electric shock when touching the machine. Ensure proper electric installation,
and let it check periodically by a trained electrician.
•
Danger due to unintended machine start-up
Eliminate this risk by disconnecting the machine before you perform any checks or activities on
the machine.
•
Hazard of inhaling toxic wood dust
Especially wood dust arising from chemically treated wood and/or lacquer/paint are harmful
when inhaled. Therefore let the dust settle for 10 Minutes before you change the dust collector
bag and wear a suitable breathing mask if required.
13
ASSEMBLY
13.1
Delivery content
Please check the product contents immediately after receipt for any eventual transport
damage or missing parts. Claims from transport damage or missing parts must be placed
immediately after initial machine receipt and unpacking before putting the machine into
operation. Please understand that later claims cannot be accepted anymore.
13.2
Workplace requirements
The workplace has to fulfill the requirements.
The ground has to be even, in level and hard. It must be suitable at least to weight it with
double weight per square meter than the machines net weight.
The chosen workplace must have access to a suitable electric supply net hat complies with the
machines requirements.
13.3
Power supply
A T T E N T I O N
When working with non-grounded machines:
Severe injury or even death may arise though electrocution!
Therefore: The machine must be operated at a grounded power socket
The connection of the machine to the electric power supply and the following checks have to be
carried out by a respectively trained electrician only.
1.
The electronic connection of the machine is designated for operation with a grounded power
socket!
2.
The connector plug may not be manipulated.
3.
The mains supply must be secured with 10A:
4.
If the connector plug doesn’t fit or if it is defect, only qualified electricians may modify or
re-new it!
5.
The grounding wire should be held in green-yellow.
6.
A damaged cable has to be exchanged immediately!
7.
Make sure that a possible extension cord is in good condition and suitable for the
transmission of power. An undersized cord reduces the transmission of power and heats up.
8.
A damaged cable must be replaced immediately