MAINTENANCE
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
16
ZI-LGR40V-AKKU / ZI-BTR40V-AKKU
To remove, press the release button (1.) and pull out
the battery (2.).
Pull out the mains plug.
10.3
Fault messages
If the LED flashes red after the battery is inserted into the charger, there is an fault with the battery
or charger.
The battery is too hot or too cold. The charging process starts when the battery reaches the
charging temperature (0 °C...40 °C).
If after some time the LED still flashes red:
Remove battery from the charger. Check contacts at charger and battery for contamination and
clean if necessary. Reinsert battery. The battery is faulty if the same display appears again.
Replace battery or have it checked in a professional workshop.
If this fault message is also displayed with a different battery, then there is a fault with the
charger. Have the charger checked by a professional workshop.
NOTICE
If the batteries are not used for a longer period of time, store them partially
charged (optimum 60%) and in a well temperatured place (10-25°C).
Recharge batteries after a longer storage period (1 year).
NOTE: Reduced operating times after recharging indicates that the battery is worn out. The
battery must be replaced.
11
MAINTENANCE
11.1
Maintenance
WARNING
Disconnect the mains plug before all work is carried out.
NOTICE
Clean your product regularly after every usage – it prolongs the products lifespan and is a
pre-requisite for a safe working environment.
Repair jobs shall be performed by respectively trained professionals only.
The products do not require any maintenance. Regularly check that the warning and safety
instructions are present on the product and that they are perfectly legible
11.2
Cleaning
Remove dirt and dust from the housing with a paint brush or dry cloth.
Keep the ventilation slits clean and dustfree.