![ZIPPER MASCHINEN 9120039233567 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/zipper-maschinen/9120039233567/9120039233567_user-manual_934720024.webp)
ASSEMBLY
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
24
ZI-STB16T
12.1.3
Preparation of the surface
Uncoated metal machine parts have been insulated with a greasy layer to inhibit corrosion.
This layer has to be removed. You can use standard solvents that do not damage the machine surface.
N O T I C E
Do not use solvents based on nitrite, aggressive solvents like break cleaners or
scrubbing agents!
These damage the machine surface.
12.2
Power supply
A T T E N T I O N
When working with non-grounded machines:
Severe injury or even death may arise though electrocution!
Therefore: The machine must be operated at a grounded power socket
The connection of the machine to the electric power supply and the following checks have to be carried
out by a respectively trained electrician only.
1.
The electronic connection of the machine is designated for operation with a grounded power
socket!
2.
The mains supply must be secured with 16A:
3.
If the connector plug doesn’t fit or if it is defect, only qualified electricians may modify or re-
new it!
4.
The grounding wire should be held in green-yellow.
5.
Check, whether the feeding voltage and the Hz comply to the required values of the machine.
A deviation of feeding voltage of ±5% is allowed
6.
After connecting, check the right running direction (400V)!
7.
Make sure that a possible extension cord is in good condition and suitable for the transmission
of power. An undersized cord reduces the transmission of power and heats up.
8.
A damaged cable must be replaced immediately
N O T I C E
Operation is only allowed with safety switch against stray current
(RCD max. stray current of 30mA)
N O T I C E
Use only permitted extension cable with cross-section the one in
the following table declared.
Voltage
Extension
Cross-section
220 V-240 V
50 Hz
<27 m
1,5 mm
2
<44 m
2,5 mm
2
<70 m
4,0 mm
2
<105 m
6,0 mm
2
Plug 400V:
5-wire:
with
N-conductor
4-wire:
without
N-conductor