37 (0x25)
Sensor temperature
compensation
(This parameter is used to
compensate the temperature
error at temperature sensor)
Temperature offset
value.
Formula:
Display temperature
= sensor reading
value + offset value
(unit = degree C)
0x00 = 0°C (Default)
0x01 = 1°C
0x02 = 2°C
0x03 = 3°C
0x04 = 4°C
0x05 = 5°C
0xFF = -1°C
0xFE = -2°C
0xFD = -3°C
0xFC = -4°C
0xFB = -5°C
Mapping Information
• BASIC Set Value 0x00 will map to Thermostat mode Off 0x00.
• BASIC set Value 0xFF will map to Thermostat mode Resume 0x05.
LISTENING MODE CHANGE (DEFAULT MODE IS FLIRS)
ZXT-120 can be configured as either “Frequently Listening Routing Slaves” (FLiRS) (if you
are using battery ) or “Always Listening” (if you are using 5Vdc adaptor) before inclusion
process. Refer to Glossary for definition of “FLiRS” and “Always Listening” node.
Important:
It is not allowed to changing ZXT-120 listening mode without exclusion process (do not
change ZXT-120 listening mode while ZXT-120 is included in a network).
13