81333 v1.12 09.21 Tudor Installation Instruction

Control Panel

Water Temperature

Zip Tudor water heaters are fully automatic, and may be left switched ON under the control of the variable 

thermostat. 
Nominal operating temperature can be varied from about 30°C to about 80°C.
Temperature should not be set to less than 50°C without due regard to regulations governing the storage 

temperature of hot water. 

Economy Setting

The economy setting “E” will maintain stored water temperature 

at approximately 50°C. At the “E” setting, the temperature control 

locates into a set position and a slight resistance will be felt when 

rotating the temperature control beyond that setting. This measure 

is to help ensure that higher temperatures are only selected 

deliberately.

Frost Protection

If the heater is located where ambient air temperature could fall below 5°C when the heater is not in use, the 

“anti freeze” setting on the temperature control will maintain stored water temperature over 5°C to prevent 

freezing and damage to the water heater.
The same protection does not extend to connecting pipework or fittings. 

Safety Cut-out

Should the heater over-heat, a manually resettable safety cut-out will automatically turn the heating element 

OFF. The cut-out must be reset by a Zip Service Provider or a licensed electrician. Users should never reset 

the cut-out without qualified assistance.

ANTI-
FREEZE

ECONOMY

HIGH

OFF

LOW

Operation

Spare parts

Part no

Description

90836

Element kit (pre-August 2019)

90852

Gasket-New Style Element Kit Tudor 2010

90854

Thermostat Kit Tudor 2010

90855

Thermal Cut-Out Kit Tudor 2010

93816

Kit Mixer Tap G4 ARC / Tudor 4-In-1, 3-In-1

96409

Overload kit Tudor (August 2019 onwards)

99039

Restrictaflow Single Pack Restrictor Flow Reducer Tudor

99371

Disabled Lever Kit - Hero Tap 4-in-1 4in1, 3in1, 3-in-1 Mixer Tap Lever Only kit Tudor

Содержание Tudor

Страница 1: ... Installation Instruction Page 1 of 8 Installation Operating Instructions Zip Tudor Single point open outlet vented under sink water heaters Model 21102 21052 Solo Hero Accessory Tapware for Under Sink Tudors sold separately ...

Страница 2: ...d for sinks and tubs not recommended for basins Zip Tudor water heaters are open outlet vented water heaters and must not be installed in the same way as mains pressure type water heaters The outlet from any Zip Tudor water heater must be connected directly to an outlet spout on the sink and must not be obstructed by a tap or valve or in any other way The water flow is controlled by a cold water t...

Страница 3: ...at the flexible tubes are firmly attached to the base of the tap body and in the correct sequence Refer tapware installation sheet Do not dismantle the assembled tap body during installation Mixer taps are factory tested and sealed to provide optimum performance To adjust water temperature delivered by Solo and Hero mixer taps see instructions on page 7 Such adjustments should be made only by a qu...

Страница 4: ... is purged from the heater Step Five Commissioning Fill the heater tank and purge air from the heater by turning the water supply ON and running water through the hot mixer tap until water flows smoothly Turn the water supply OFF and turn the power supply ON The heater will then run through its heating cycle During the heating cycle drips fall from the delivery spout or tap Dripping will cease whe...

Страница 5: ...see page 3 Position heater 1 metre from tap see page 3 Install approved vented tapware see page 3 WIDTH 255 5L 310 10L HEIGHT 390 5L 455 10L 100 70 DEPTH 215 5L 265 10L 140 COLD IN HOT OUT UNDER SINK INSTALLATION I I I I I I I I E E ZIP ZIP T Tudor udor 140 5L 180 10L 250 5L 275 10L SIDE VIEW FRONT VIEW FIXING HOLES WALL Wall fixing details 4 mm gap Anchor Bolt Screw Head Wall Installation Quick i...

Страница 6: ... temperature could fall below 5 C when the heater is not in use the anti freeze setting on the temperature control will maintain stored water temperature over 5 C to prevent freezing and damage to the water heater The same protection does not extend to connecting pipework or fittings Safety Cut out Should the heater over heat a manually resettable safety cut out will automatically turn the heating...

Страница 7: ... 4 Carefully lift off the case To replace the case perform the above procedure in reverse Replacing a thermostat 1 Remove the front cover 2 Disconnect the two electrical terminals from the thermostat These are spade connectors and can be easily pulled off 3 Remove the two screws attaching the thermostat to the plastic upright 4 Pull the capillary out of the thermostat pocket located on the element...

Страница 8: ... Ltd ABN 46 000 578 727 67 77 Allingham Street Condell Park NSW 2200 Postal Locked Bag 80 Bankstown 1885 Australia zipwater com 612 9796 3100 1800 ZIP TAP 1800 947 827 Zip products described in this publication are manufactured under one or more of patents and further patent applications are pending As Zip policy is one of continuous product improvement changes to specifications may be made withou...

Отзывы: