Technical data

Model

Tudor II and Contract II models

Nominal supply voltage

1/N/PE 230V~

Power rating (kW)

1.8

Rated Current (A) 

7.8

Element type

Embedded Rod

Maximum supply pressure 

0.35MPa (3.5 bar)*

Temp. Adjustment range 

35°C~80°C

Capacity

5 Litre

 

10 Litre 

Dimensions H x W x D (mm)

390x255x215

440x310x265

Minimum weight (kg) (Empty)

3.5

4.0

Maximum weight (kg) (Full))

8.5

14.0

Rated volume  (litres)

5

10

Water connections (BSP)

1/2”

Protection class

IP24

All data quoted at nominal supply voltage.
For higher supply pressures it is recommended that a Zip AQ3 (set at 3.5 bar) pressure reducing 
valve is used.

ZIP 

Tudor II 

ZIP 

CONTRACT 

   

W

   

D

     

H

   

D

   

W

     

H

C3/50

Tudor II, C2/50 and C2/100

NOTE: 

Overbasin and underbasin models are NOT interchangeable. For underbasin applications use 

models  designated ‘UB’ and use only Zip approved vented tap accessories.

Содержание Tudor II P4/52

Страница 1: ...Please read these instructions carefully before commencing installation of the water heater Please leave these instructions with the end user after installation Zip Heaters UK Ltd 14 Bertie Ward Way...

Страница 2: ...re commencing installation of the Point of Use Water Heater Please leave these instructions with the end user after installation To ensure you have a copy of the latest instructions visit www zipheate...

Страница 3: ...ater that occurs during the heating cycle to be safely discharged During the heating cycle drips will form and fall from the delivery spout or tap and these will cease when the cycle has been complete...

Страница 4: ...ce its wiring and piping must not be modified in any way In case of malfunction isolate the power supply immediately In case of leaks also isolate the water supply Repairs must only be carried out by...

Страница 5: ...NO CIRCUMSTANCES SHOULD THE SPOUT OR OUTLET BE CONNECTED TO A TAP WHICH IS CAPABLE OF BEING CLOSED The Zip Tudor II and Contract II is intended for connection to mains supply only In any other case p...

Страница 6: ...310x265 Minimum weight kg Empty 3 5 4 0 Maximum weight kg Full 8 5 14 0 Rated volume litres 5 10 Water connections BSP 1 2 Protection class IP24 All data quoted at nominal supply voltage For higher su...

Страница 7: ...settable cut out CT0122 X 5a Thermal fuse CT0120 X 6 Neon light indicator CT0129 4 X X 7 Retaining nut CT0115 4 X X X 8 Front cover 5L CT0103 3 X 8 Front cover OB 5L CT0123 X 8 Front cover UB 5L CT012...

Страница 8: ...solating valve should be installed in the water supply line to the heater A minimum clearance of 270mm is required underneath the overbasin heater units and above the underbasin units to allow for the...

Страница 9: ...d Supply In Hot to Tap ZIP Approved Vented Tap Underbasin Installation In all underbasin installations the outlet must be connected to an open outlet type fitting approved by Zip heaters The diagram b...

Страница 10: ...e wired with a 1 metre length of cable If in the lifetime of the unit the cable is damaged or a greater length of cable is required then to replace the supply cable refer to the following Cable instal...

Страница 11: ...imply switching off the electrical supply to the unit for at least 2 minutes When power is restored the cut out will have reset However if the fault persists then the unit should be isolated from the...

Страница 12: ...r no circumstances is the water heater to be used if suspected of being frozen If water ceases to flow switch off the electrical supply immediately at the isolating switch It is then recommended that...

Страница 13: ...Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted or modified as between the owner...

Отзывы: