806835 v1.08 05.23 G5 User guide

11

 SECTION 2: Using the HydroTap

2.4 Celsius Plus AIO Pull-Out 

 

continued

Spray hose 

Pull out the spray nozzle with its 

integral handle. Use the mixer control
 to dispense, see page 13. 

Mixer 

control 

Spray function 

Press the 

spray button to change the 
water flow from an aerated  
stream to a spray. The button 
will remian pressed during 
the spray mode. 

Return to Aerated stream

 

Close off the mixer control 
for the button to return to 
normal position, then open 
the mixer control again for 
aerated water stream.

Spray nozzle 

handle  

!

Spray safety lock

Self-return

The spray hose 
has a controlled 
self-return  
for ease of use. 

The boiling water 
icon turns off when 
the spray hose is 
pulled out  
indicating that  
boiling water  
cannot be 
dispensed.

Close

Return

(button)

Содержание HydroTap G5 H57783Z07AU

Страница 1: ...806835 v1 08 05 23 G5 User guide 1 User Guide HydroTap G5 Visit our website to download the manuals Australia UK...

Страница 2: ...System settings 19 3 5 1 Filter settings 20 3 5 2 Temperature settings 23 3 5 3 CO2 settings 25 3 5 4 Dispense times 27 3 5 5 Light sensor 27 3 5 6 Quiet mode 28 3 5 7 Advanced settings 1 28 3 5 8 Ad...

Страница 3: ...r product Register product REGISTER PRODUCT 12 12 PM Congratulations on purchasing a HydroTap system Scan the QR code on your phone to register your product Congratulations on purchasing a HydroTap sy...

Страница 4: ...ic shock Hot surface SECTION 1 SAFETY 1 2 Before you start Read the WARNINGS and PRECAUTIONS Download read the complete Command Centre installation instruction manual and user guide Read and use the i...

Страница 5: ...ap SAFETY BOILING CHILLED CHANGE FILTER SAFETY Touch free Arc Arc Plus Cube Cube Plus and Celsius Touch Free Wave Classic Plus Elite Plus See page 6 See page 7 See page 9 Classic HydroTap Mixer Taps S...

Страница 6: ...N Ready to dispense FLASHING SLOWLY Water temperature not at set point FLASHING QUICKLY System fault Simply press to dispense chosen water type Safety lock Safety lock Service ON Safety lock on OFF Sa...

Страница 7: ...activated water dispensed BLUE Chilled sensor activated water dispensed WHITE Sparkling sensor activated water dispensed PURPLE Lock mode on when tap is idle Flashing RED Sensor activated incorrectly...

Страница 8: ...s Sensor range 1 4cm To dispense hold hand within range of the sensors Tap will not operate and light will flash if the sensors are touched or if your hand is too close Boiling Water Chilled Ambient S...

Страница 9: ...boiling water Indicator displays system status Select touch to select water type SAFETY SAFETY SAFETY LOCK ON Lights Indicator Select Safety ON Ready to dispense SINGLE COLOUR FLASHING SLOWLY Water t...

Страница 10: ...WLY Water temperature not at set point FLASHING QUICKLY System fault Press hold the relevant symbol to dispense chosen water type Safety lock Safety lock Service Light ON Safety lock enabled double ta...

Страница 11: ...from an aerated stream to a spray The button will remian pressed during the spray mode Return to Aerated stream Close off the mixer control for the button to return to normal position then open the mi...

Страница 12: ...imed dispense Lights BOILING CHILLED CHANGE FILTER SAFETY Dispense options Boiling ready Chilled sparkling ready Filter Use boiling chilled sparkling or ambient lever to dispense your water choice ON...

Страница 13: ...08 05 23 G5 User guide 13 SECTION 2 Using the HydroTap 2 6 HydroTap Mixers Controls mixed water Hot Cold Rotate the lever front to back change the water temp Rotate the lever left to right change the...

Страница 14: ...top left icon to navigate to the main menu Then touch the general settings icon to navigate to the general settings menu MAIN MENU 12 12 PM General Settings System Settings Safety Security Energy Savi...

Страница 15: ...d Centre ON or OFF The LCD screen visually shows OFF when it is non operational You will hear the sound of an internal click as the HydroTap Command Centre turns ON or OFF When OFF all functions are d...

Страница 16: ...CO2 GAS REMAINING REPLACE CO2 GAS When the CO2 cylinder has approximately 20 remaining a warning appears to encourage you to prepare a replacement cylinder Filter life remaining A warning icon is show...

Страница 17: ...entre Screen 3 3 Main menu Use the Main menu to configure your HydroTap and access features and settings Touch each icon to access further options 3 4 General settings Language LANGUAGE 10 50 Imperial...

Страница 18: ...then press and to set the current date and time Press the tick to confirm and save DATE TIME 2021 Dec 06 10 50 24 hr Time Mon 12 12 PM Network Connect to Wi Fi available with optional Zip Assist Kit N...

Страница 19: ...806835 v1 08 05 23 G5 User guide 19 3 5 System settings Configure your HydroTap to suit your needs Navigate to system settings screen for all system settings SECTION 3 Command Centre Screen...

Страница 20: ...missioning of a new installation and after every filter change See page 36 for filter change instructions 3 5 1 Filter settings FILTER SETTINGS 12 12 Filter Reset Filter Life Filter Flush Open filter...

Страница 21: ...lushed through the filter This process is automatic and will take 2 minutes Press pause to pause filter flush 12 12 PM Approximately 10L of water will flow for 2 minutes The screen will show the filte...

Страница 22: ...internal external filter and edit the filter life months or litres and actual usage days or litres When usage exceeds the filter life the tap lights and screen will indicate to change the water filter...

Страница 23: ...perature setting Up to 6 less energy in standby is consumed with a 98 C set point rather than 100 C A warning icon will appear when setting boiling set point temperatures that are subject to pump cavi...

Страница 24: ...tes or go to this menu to recalibrate Calibration will take around 10 minutes 12 12 BOILING CALIBRATION 88 0 C 80 0 C Boiling Water Temp Steam Vent Temp 0 Element Power Calibrating Safety Hot External...

Страница 25: ...pes from the tap The purge process stops automatically 3 5 3 CO2 settings 12 12 PM PURGE WATER WITH CO2 INFO This process removes water from the sparkling chamber when a new CO2 bottle is installed Th...

Страница 26: ...o grams absorbed Months of use may also be selected to trigger a reminder to prepare a replacement CO2 cylinder Usage is dependent on CO2 absorption settings on the HydroTap and leak free installation...

Страница 27: ...room is typical for operating conditions The lights on the tap will flash to confirm calibration When the room is darkened below the calibrated light level the tap lights will turn OFF after 30 secon...

Страница 28: ...se Power Pulsing Mode Hot setpoint must be 98 5 C to disable Periodic Pulse Reduced Cavitation Mode Sends two electric pulses every 5 minutes to the pump This prevents the build up of air bubbles insi...

Страница 29: ...ock Mode Dual Sensors Required for Chilled Sparkling Wave Tap Sensor Demister Mode Enabled default activates the Wave Tap internal heater to prevent its sensors from being affected by condensation fro...

Страница 30: ...ng safety lock Use the safety button to dispense hot water Hot isolation additional boiling safety 3 slow safety button presses required prior to dispensing Boiling safety lock Enabled default safety...

Страница 31: ...ion to limit access to certain settings Users will be prompted for this passcode when attempting to access settings Create a 4 digit passcode and re enter as prompted The passcode will be deactivated...

Страница 32: ...bled default Enabled Any attempt to dispense water will bring the HydroTap out of sleep mode Allow sufficient time for the water to reach the set temperature Sleep when Select from It gets dark Not us...

Страница 33: ...n that is in effect is highlighted When OFF the HydroTap will stop chilling and heating the drinking water During OFF mode any attempt to dispense water will bring the HydroTap back ON Allow sufficien...

Страница 34: ...f your HydroTap by viewing the total energy consumed and the energy consumed since the last energy use reset 12 12 PM SET TIMER Off at On at Mon Tue Wed Thu Fri Sat Sun 00 23 00 23 3 7 2 On Off Timer...

Страница 35: ...cent Faults ABOUT SYSTEM 12 12 PM Title Info Module App revision Serial No Product No Calibration 50L Filtered Wi Fi MAC Address BCS100 017 H5v0 1 xx 0000000000000 H500xx000US N A N A BS 0 00 FW 0 00...

Страница 36: ...he filter may require changing before the filter change indication is shown You may also need to replace the filter if you notice an increase in chlorine taste or odour Place a cloth or towel under th...

Страница 37: ...ge 20 Clean up and dispose of old cartridge and packaging If the HydroTap is switched off for a long period of time e g more than a weekend run water through the chilled water outlet for at least 60 s...

Страница 38: ...all taps Command Centre and ancillaries wipe external surfaces with a gentle cleaning agent or a damp cloth and then wipe dry immediately with a clean dry cloth Do not use strong corrosive spray or ab...

Страница 39: ...uctions SECTION 4 User maintenance Components Cylinder Regulator I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I IIII I I I I I I I I I I I I I I I...

Страница 40: ...I I I I IIIIIIIII I I I I I I I Cylinder pressure Outlet pressure Regulator control knob Cylinder connection Gas hose connection Set to 3 0 bar SECTION 4 User maintenance Universal G5 CO2 regulator 1...

Страница 41: ...IIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I Replace cylinder and refit regulator I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I...

Страница 42: ...place cylinder and refit regulator inc adaptor I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I I I I I I I I I I I I IIIIIIIII I I I I I I I I I...

Страница 43: ...strap Unscrew regulator connection Replace cylinder and refit regulator Strap in place Turn ON regulator valve Test for leaks in these areas Test for leaks by brushing with soapy water and looking for...

Страница 44: ...UK Trafalgar House Rash s Green Dereham Norfolk NR19 1JG 0345 6 005 005 sales zipindustries co uk specify zipwater co uk AU02691 As Zip policy is one of continuous product improvement changes to speci...

Отзывы: