Zip HydroTap BC Скачать руководство пользователя страница 2

193mm

234mm

Positioning

Position the tap such that it dispenses into the 
sink bowl with clearance for a cup or tea pot. 

Ensure that taps are positioned to minimise 
the risks of scalding when dispensing 
boiling water.

!

1

2

Position Command Centre  
and Tap as close together as 
possible. See below.

Cut the hole 

• 

Cut a Ø50mm hole in the worktop / sink.

Ø50mm

Familiarise yourself with the tap connections

Fit braided hoses, matching

the hose colours to the tap

BLUE Chilled  

tube 

RED

Boiling  

tube

CLEAR

Vent  

tube

USB

Sparkling  

models

Mains connections

See

 

6

Command 

Centre  

quick guide

4

Familiarise yourself with the tap connections

3

Check the hose, USB,and pipe positions on the base 
clamp.

Blue marked  

braided hose

White marked  

braided hose

Blue silicone  

tube

Clear  

silicone tube

Red silicone  

tube

Red marked  

braided hose

USB cable

Mount and secure the tap

Base clamp

O-ring

Fixing nut

5

BCS Comm

InLine

E L E C T R O N I C

7

Use a tube spanner to secure 
the tap in place.

Using these instructions

Please refer to all safety and installation requirements 

detailed in the Quick start guide provided with the 

HydroTap Command Centre, and HydroTap Command 

Centre installation instructions found online, prior to 

installation of, or any change to, the complete system.

Before commencing the 
installation,download 
& read the HydroTap 
Command Centre 
installation instructions

!

Read the  

instructions

WARNING

Tools needed for tap installation

 

In addition to normal tools, the following (or equivalent 
equipment) will be required

.

• 

50mm diameter sheet metal hole punch for sinks.

• 

50mm diameter hole saw for worktops.

• 

Tube spanner for fixing the tap assembly (supplied).

Be aware of the risks of hazards which could  
cause harm when using tools. Assess the 
risks before starting the installation.

!

Min - Max pressure, kPA (bar) 
Australia

UK

HydroTap

 170 (1.7) - 700 (7.0)

 170 (1.7) - 500 (5.0)

Sparkling 

HydroTap

 250 (2.5 ) - 700 (7.0)

 250 (2.5) - 500 (5.0) 

Booster

200 (2.0) - 700 (7.0)

200 (2.0) - 500 (5.0)

    Water supply pressure requirements