193mm
234mm
Positioning
Position the tap such that it dispenses into the
sink bowl with clearance for a cup or tea pot.
Ensure that taps are positioned to minimise
the risks of scalding when dispensing
boiling water.
!
1
2
Position Command Centre
and Tap as close together as
possible. See below.
Cut the hole
•
Cut a Ø50mm hole in the worktop / sink.
Ø50mm
Familiarise yourself with the tap connections
Fit braided hoses, matching
the hose colours to the tap
BLUE Chilled
tube
RED
Boiling
tube
CLEAR
Vent
tube
USB
Sparkling
models
Mains connections
See
6
Command
Centre
quick guide
4
Familiarise yourself with the tap connections
3
Check the hose, USB,and pipe positions on the base
clamp.
Blue marked
braided hose
White marked
braided hose
Blue silicone
tube
Clear
silicone tube
Red silicone
tube
Red marked
braided hose
USB cable
Mount and secure the tap
Base clamp
O-ring
Fixing nut
5
BCS Comm
InLine
E L E C T R O N I C
7
Use a tube spanner to secure
the tap in place.
Using these instructions
Please refer to all safety and installation requirements
detailed in the Quick start guide provided with the
HydroTap Command Centre, and HydroTap Command
Centre installation instructions found online, prior to
installation of, or any change to, the complete system.
Before commencing the
installation,download
& read the HydroTap
Command Centre
installation instructions
!
Read the
instructions
WARNING
Tools needed for tap installation
In addition to normal tools, the following (or equivalent
equipment) will be required
.
•
50mm diameter sheet metal hole punch for sinks.
•
50mm diameter hole saw for worktops.
•
Tube spanner for fixing the tap assembly (supplied).
Be aware of the risks of hazards which could
cause harm when using tools. Assess the
risks before starting the installation.
!
Min - Max pressure, kPA (bar)
Australia
UK
HydroTap
170 (1.7) - 700 (7.0)
170 (1.7) - 500 (5.0)
Sparkling
HydroTap
250 (2.5 ) - 700 (7.0)
250 (2.5) - 500 (5.0)
Booster
200 (2.0) - 700 (7.0)
200 (2.0) - 500 (5.0)
Water supply pressure requirements