background image

Zip Hydroboil Electronic - Installation & Operating Instructions - 86584 - July 2008

Page 7 of 16

274 (1.5 L & 3.O L)

304 (5.0 L & 7.5 L)

65 CLEAR

56

POSITIONING PIN

EXTERNAL  PLUMBING

ELECTRICAL WIRING
POSITION

INTERNAL PLUMBING

72

15

25

35

42

COLD
INLET

VENT

BENCH TOP

416 3.O L
448 5.O L
561 7.5 L

38 (1.5 L & 3.O L)

53 (5.0 L & 7.5 L)

150
CLEAR

19

20

Wall Mounting Template Dimensions 

End of life Disposal

The use of this crossed out wheeled bin logo indicates that this product needs
to be disposed of separately to any other household waste.

Within each of the European Union member countries, provisions have been
made for the collection and recycling of unwanted electrical and electronic
equipment. Outside of the EU it will be necessary to dispose of this product at
your local community waste collection or recycling centre.

In order to help preserve our environment we ask that you dispose of this
product correctly. Please contact your local city council for collection centre
details

Wall Mounting Template Dimensions 

[email protected]

www.chilli-b.co.za | 012 809 4026

[email protected]

www.chilli-b.co.za | 012 809 4026

Содержание Hydroboil 203062

Страница 1: ...Hydroboil 3 Litre White 203061 Zip Hydroboil 3 Litre Stainless Steel 205062 Zip Hydroboil 5 Litre White 205061 Zip Hydroboil 5 Litre Stainless Steel 207062 Zip Hydroboil 7 5 Litre White 207061 Zip Hy...

Страница 2: ...Page 2 of 16 Zip Hydroboil Electronic Installation Operating Instructions 86584 July 2008 retha chilli b co za www chilli b co za 012 809 4026 antonius chilli b co za www chilli b co za 012 809 4026...

Страница 3: ...stallation Requirements 4 Installation Procedures 5 6 Step 1 Positioning 5 Step 2 Fastening 5 Step 3 Connecting 6 a Plumbing 6 b Venting 6 c Electrical 6 Step 4 Assembling 6 Step 5 Commissioning 6 Wal...

Страница 4: ...bient air temperature could fall below 5 C when the heater is not in use do not turn off the appliance electrically This safeguard does not offer the same protection to the connecting pipework and fit...

Страница 5: ...he tap will drain on to a draining board or drip tray Position the base of the tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger v...

Страница 6: ...he heater rear using a visible tundish see diag at left c Electrical For concealed electrical connection connect a power cable through the rear access opening of the heater to the terminal block withi...

Страница 7: ...ct needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for the collection and recycling of unwanted electrical...

Страница 8: ...iance must be earthed Following remedial service the earthing continuity of the heater must be checked by a qualified technician using an appliance tester or continuity tester of accuracy Class 5 or b...

Страница 9: ...indicator is illuminated Warning The unit is now capable of dispensing boiling water without the safety feature Dispensing Boiling water Zip Hydroboil is fitted with a safety two way cool touch safet...

Страница 10: ...an have 2 ON OFF times per day If the user selects either of the energy saver modes see below ON OFF mode cannot be used The user is not able to access this part of the configuration The real time clo...

Страница 11: ...of the stored water to drop to and be maintained at 65 C As soon as the ambient light rises above 100lux the Hydroboil returns to full power mode A normal office has an ambient light level of 200 300l...

Страница 12: ...HE WEEK To return to Normal Mode press CSS4 To step to the next day of the week press either CSS2 or CSS3 To step to the next configuration parameter press CSS1 SET FILTER EXPIRATION TIME To return to...

Страница 13: ...sensor is configured as off the user will be able to use ON OFF mode SUN ON TIME 1 To return to Normal Mode press CSS4 To increment the hour for SUN ON TIME 1 press either CSS2 or CSS3 To step to the...

Страница 14: ...732 Tap Handle Kit 15 90745 Outlet Nozzle Kit Grey 16 90503 Strap and Key Kit 3Litre Hydroboil 16 90504 Strap and Key Kit 5L 7 5Litre Hydroboil 17 90505 Tap Nut Kit 18 90509 Tap Body Kit 19 90485 Elem...

Страница 15: ...droboil Electronic Installation Operating Instructions 86584 July 2008 Page 15 of 16 Spare Parts retha chilli b co za www chilli b co za 012 809 4026 antonius chilli b co za www chilli b co za 012 809...

Страница 16: ...water quality and the rate of water consumption Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excl...

Отзывы: