Step C - Connecting the tap  

                                                                   

Model BC (boiling/chilled models)

Measure and trim the blue tube and connect it to the chilled water outlet 
located on the top front, right hand side of the undersink unit. Use spring 
clamps provided.

Measure and trim the red marked tube and connect it to the hot water outlet 
located on the top centre, right hand side of the undersink unit. Use spring 
clamps provided.

Measure and trim the unmarked tube and connect it to the vent outlet located 
on the top centre, left hand side the top of the undersink unit. Use spring 
clamps provided. 

NOTE:

 All tubes must have a continuous fall back to the 

undersink unit.

Connect the tap USB connector to the USB lead on the undersink unit. Orient 
the USB plug carefully and connect, do not force the plug. Once connected, fix 
the cable to the wall, ensure it is away from any possible water splashes and 
is off the floor. 

Note:

 

When trimming any silicon tubes trim to minimum length, do not loop 

any excess or allow kinking of the tubes. When connecting, slide the tube over 
the pipe at least 25mm. There are black plastic clamps provided on the boiling 
and chilled hoses to choke the flow if required. Only choke the flow if it is 
excessively strong.

Model B  (boiling only models)

Measure and trim the red marked tube and connect it to the hot water 
outlet,  on  the  top  of  the  undersink  unit.  Use  spring  clamps  provided.                                             
Measure and trim the unmarked tube and connect it to the vent outlet on the 
top of the undersink unit. Use spring clamps provided.     

NOTE: 

Both tubes must have a continuous fall back to the undersink unit.

Connect the tap USB connector to the USB lead on the undersink unit. Orient 
the USB plug carefully and connect, do not force the plug. Once connected, fix 
the cable to the wall, ensure it is away from any possible water splashes and 
is off the floor. 

Step D - Connecting an external filter.

 

BC160/125+ and BC200/175+ only.

(Not supplied as standard equipment).

To combat the build up of lime scale, a high performance external filter kit 
may be ordered from your Zip service provider. 

NOTE:
-

 When fitted, the external filter will supply filtered water only for the Hot tank. 

The internal filter will continue to supply filtered water for the cold tank.

-

 The external filter may require the inlet water pressure to be regulated to 

lower than 6 bar. In this case a 3.5 bar (350 kPa) Pressure Reduction Valve 

will be required.

 

Installation Procedure 

continued

Vent line 

Chilled line 

Hot line 

Front

Vent

Hot Outlet

Rear panel with external filter fittings

BC120/60+

HOT outlet

Chilled outlet

USB and power 
cable

Inlet

Vent

Содержание Commercial HydroTap 86682

Страница 1: ...ge 1 of 20 Commercial HydroTap Filtered boiling and chilled drinking water for Commercial kitchens and tea rooms Installation and Operating Instructions This Installation Instruction covers the follow...

Страница 2: ...r counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all plumbing...

Страница 3: ...adjustment 11 Font Installation Procedure 12 Operating the Tap 13 Child Safety lock 14 Cleaning 14 Setting the Energy Saver Timer 15 Auxiliary Fan Attachment 16 Boiling Water Isolation 16 Set the Hot...

Страница 4: ...ake care when lifting the Zip HydroTap undersink unit Some units may exceed safe lifting guidelines If you feel this is beyond your personal capabilities please seek assistance with the lift The weigh...

Страница 5: ...ce Provider Frost Protection If this appliance is located where the ambient air temperature could fall below 5 C when the heater is not in use do not turn off the appliance electrically This safeguard...

Страница 6: ...ace in the cupboard to install the undersink unit in accordance with these Installation Instructions A table of dimensions is given above NOTE Add 65mm to the Depth of the undersink unit to allow for...

Страница 7: ...et on the unit For BC120 60 model connect the plastic inlet hose supplied to the cold water inlet on the unit This is located at the rear of the unit Position the Zip HydroTap undersink unit as close...

Страница 8: ...ow if required Only choke the flow if it is excessively strong Model B boiling only models Measure and trim the red marked tube and connect it to the hot water outlet on the top of the undersink unit...

Страница 9: ...jacent surface measure and trim the filter inlet and filter outlet tubes Fit the tubes to their respective inlets and outlets checking to ensure the flow of water corresponds to the direction indicate...

Страница 10: ...ane Press the adjust button again to stop the Filter Flush Mode Turn OFF the Filter Flush stop cock and re locate the tube and stop cock in the filter compartment Turning OFF the Filter Flush Mode put...

Страница 11: ...it will show the following Hot Temp Lvl Cold Temp Lvl NOTE The temperatures shown are actual not the set temperatures To revert back to the Normal Operation screen press the adjust buttons together ag...

Страница 12: ...ixing nut with the Tube Spanner provided in the kit 6 Tighten the securing pin so the Font base is flush with the bench top NOTE The fixing nut above the drain elbow can be loosened to correctly posit...

Страница 13: ...thin its normal specified lifespan Filter Change Light Flashing slowly The light will flash slowly when the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the fil...

Страница 14: ...ly Safety Lock boiling only models To activate the safety lock go to the LCD display using menu or buttons scroll to the Safety Lock display To turn ON adjust button to turn OFF adjust button After ab...

Страница 15: ...Activating Sleep Mode This mode allows the HydroTap to go into Energy Saving mode In this mode the unit will go to sleep after a predetermined period of inactivity Press either Menu or Menu button unt...

Страница 16: ...mode is active 5 To temporarily de actvate and dispense boiling water press the Safety Lock 3 three times rapidly the LED s will scroll from right to left 3 three times This operation confirms de act...

Страница 17: ...f this isolates the water supply 2 Open the left door or on the compact model remove the front cover 3 Relieve system pressure via the filter flush stop cock a quick open and close will do 4 Grasp fil...

Страница 18: ...ion Check water supply is on Check to ensure plumbing connection is made Check power plug is correctly fitted and switch is turned on Check for loom connection Contact local Zip Service Provider Check...

Страница 19: ...Hydro Tap Installation and Operating Instructions 86682 March 2012 v1 05 Page 19 of 20 Typical undersink layout 50 50 Fused Spur...

Страница 20: ...urned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance the use of non authorised parts or consequential damage to any other goods...

Отзывы: