Zip Chillmaster- Installation & Operating Instructions - 81495 - January 2012 v1.00
Page 5 of 8
Plumbing
See Illustration on page 4.
The Chillmaster is designed for direct connection to a cold water supply.
The valves can be fitted completely within the Chillmaster chassis, or can
be remotely installed into the incoming water line externally. In either case,
connect the incoming water line to the 1/2” compression fitting on the end
of the valve assembly.
If mounted externally, run separate tubing from the valve outlets into the
Chillmaster. If fitted internally, mount the valves in the space at the rear
upper right hand side next to the drain piping and the filter. Connect the
1/4” tubing from the regulated valve outlet to the filter. Connect the 1/4”
tubing from the pressure relief valve drain to the JG tee on the carafe filler
blue and clear tubes.
Connect a drain to the 40mm PVC female outlet at the back.
If the plumbing is through the bottom of the unit, adjust the bowl trap to
point downwards.
Reconnect the bubbler and carafe filler tee to the chiller outlet tube that
you disconnected earlier. Refit and attach the bowl top to the chiller using
the original screws. Purge the air from the unit when the plumbing is
complete by turning ‘ON’ the water supply, pressing the button on the
bubbler and the lever on the carafe filler until the water flows through
without spluttering. Check the unit for leaks. Repair any found.
Note:
For Australia / New Zealand the plumbing installation must be
done in accordance with AS3500, local Water Authority by-laws and
these Installation Instructions.
For the UK this product is a WRAS approved showing that it complies
with: Water Fittings Regulations in England and Wales, the Water
Byelaws 2000 in Scotland and the Water Regulations in Northern
Ireland.
Electrical
Note:
For Australia and New Zealand a 1.8m flexible cable and 240V
50Hz 3 pin plug are supplied fitted. Run the cable out of harm’s way
and plug it into a standard 10A power point.
For the UK the power supply is a fused spur for connection to the
heater via a double pole fused spur with a minumum break rating
that adequately covers the maximum power usage.
If the cable was installed recessed, disconnect the flex and plug, and
directly connect the supply cable to the terminal block inside the unit. DO
NOT turn the power point ‘ON’ until the unit is purged.
If not yet installed, fit the filter change reminder light batteries to the circuit
board matching the polarity. See the filter replacement reminder light
instructions for timer setting details.