background image

16

807066 v1.01 08.21 HBP AB 21 Install Instructions

Step 7 – Tap operation

Boiling water will be dispensed

Press lever to dispense boiling 
water.

!

Push to lock for continuous flow.
If lever does not lock, rotate it 180° 
before dispensing.

7.1 Tap operation: Autoboil

Ensure the red lock button on 
the right hand side of the control 
panel is in a depressed position. If 
not, push the button and simulta-
neously rotate it 90°. The button 
should remain depressed.

Gently push the tap to dispense boiling 

water.

Lift the tap until it locks in a horizontal 

position, for continuous flow.

7.2 Tap operation: Hydroboil Plus

Содержание Autoboil

Страница 1: ...07066v1 0108 21HBPAB21InstallInstructions Installation instructions Zip Autoboil Hydroboil Plus Onwallboilingwater Models Hydroboil Plus 3L 5L 7 5L Autoboil 3L 5L 7 5L 15L 25L 40L Available in Austral...

Страница 2: ...2 807066v1 0108 21HBPAB21InstallInstructions...

Страница 3: ...ECAUTIONS 5 TECHNICAL SPECIFICATION 6 Step 1 Positioning 7 Step 2 Fastening 8 Step 3 Plumbing connection 10 Step 4 Electrical connection 11 Step 5 Assembly 13 Step 6 Commissioning 14 Step 7 Tap operat...

Страница 4: ...Venting Occasionally steam and or boiling water may discharge through a vent outlet or the tap Ensure the tap body is located so the tap outlet safely dispenses into the drip tray or sink bowl area an...

Страница 5: ...ove the cover of the appliance under any circumstances without first isolating the appliance from the power supply 9 The cold water supply to this appliance must be potable and fall within your local...

Страница 6: ...ht when full of water See Technical specifications Sufficient space is provided to install the appliance and other components in accordance with these installation instructions Check cable and plumbin...

Страница 7: ...e appliance on the wall Place supplied paper template on the wall Drill holes as shown OPTION Drill holes for concealed plumbing water inlet vent outlet and electrical x x x x 1 1 1 2 100mm 3L 5L 7 5L...

Страница 8: ...allInstructions Step 2 Fastening 3 7 5 litre models 15 40 litre models Remove 4 screws Remove the cover Use supplied screws to mount the appliance to the wall 2 1 Autoboil twist the tap 90 degrees to...

Страница 9: ...ble gland Terminal block Concealed access AU NZ remove filter guide for installation 1 2 15 40 litre models Strain relief bush cable gland Concealed access Filter AU NZ models Terminal block Escutcheo...

Страница 10: ...length must have no more than 3 right angle bends Vent External tundish 3 2 Concealed inlet 45mm Concealed vent Concealed plumbing connection Connect cold water pipe through the rear of the appliance...

Страница 11: ...Connect a concealed power cable through the rear access opening to the terminal block live active and neutral wires via the strain relief bush Tighten the strain relief bush to secure the cable Crimp...

Страница 12: ...ains input 806010 v3 1 Red 2 Blu 2 Blu 1 Red Overload Chassis Earth Tab N E L2 L1 L2 L3 L4 T1 T2 T3 T4 Contactor A1 A2 2 Red Blk L1 Brn Brn 1 1 Bl Bl Blk Grn Yel Brn Brn Blk Blu Thermostat Blk Red Red...

Страница 13: ...filter guide 5 1 Push filter guide upwards Rotate clockwise until locked Refit cover Fix with screws top and bottom Apply thread tape to thread Turn tap until it touches the lock nut and is upright Us...

Страница 14: ...Do not turn ON electrical power until instructed Water must be available from the tap outlet to prevent damage Water dispensed during commissioning may be boiling Filter flush Australian models Check...

Страница 15: ...te circle left of the Tick to Continue Boiling Calibration will commence Allow several minutes for the water to boil Calibrating Completed When completed as prompted turn on the mains water supply Sel...

Страница 16: ...ate it 180 before dispensing 7 1 Tap operation Autoboil Ensure the red lock button on the right hand side of the control panel is in a depressed position If not push the button and simulta neously rot...

Страница 17: ...nges according to the button action A button has no function when no icon is shown 1 Understanding icons and buttons Move to the next item highlighted Move to the previous item Confirm menu selection...

Страница 18: ...de There are 3 Home screen modes Normal mode Sleep mode Sleep override mode Current water temperature Fault Indication Current Date Time Filter days remaining Daily Energy Consumption Navigate to Main...

Страница 19: ...te to Main Menu Enter Sleep Override Mode Navigate to Fault Menu Show more information Trigger Indication Exits sleep mode at the time shown Exits sleep mode when ambient light returns to normal brigh...

Страница 20: ...PAB21InstallInstructions Screen operation 3 MAIN menu Main menu from Home Screen Scroll menu options Select option 4 SETTINGS Settings Date Time Set the date time Settings Temperature Set the Boiling...

Страница 21: ...ons Screen operation Settings Sleep Modes menu Sleep Trigger Select the trigger that will enable Sleep Mode Sleep Action Select either reduced water temperature or switch off the appliance Timer Setti...

Страница 22: ...r External filter to continue Life Usage Set the filter life default 12 months refer to the filter cartridge and the actual filter usage Disable to prevent filter change reminders Replace Filter Selec...

Страница 23: ...gs Install menu Light Calibration Calibrate the operating ambient light in order to trigger sleep mode when the light dims below ambient Boiling Calibration Follow the instructions on the screen to ca...

Страница 24: ...24 807066v1 0108 21HBPAB21InstallInstructions Screen operation Settings Info menu Product Info Current Faults Refer to Troubleshooting to identify fault codes...

Страница 25: ...es before consumption Use only a Zip Filter in this product to ensure effective filtration and operation Replacement filter cartridges can be obtained through plumbing suppliers or directly from Zip F...

Страница 26: ...y PCB faulty element faulty cut out Check power supply Contact Zip authorised agent Runs out of boiling water and fails to refill Outlet tap drips Overflow from vent Excessive steam from vent Power on...

Страница 27: ...log a boiling calibration has successfully occurred and recorded 2 parameters Unit should continue to work normally If not contact a Zip authorised agent Cleaning End of life disposal Do not use stro...

Страница 28: ...t prior notice Images in this booklet have been modified and may not be true representations of the finished goods 2021 Zip Water Aust Pty Ltd Zip Water Aust Pty Ltd ABN 46 000 578 727 67 77 Allingham...

Отзывы: