Zip Autoboil

315052 Zip Autoboil 15 Litre White

313051 Zip Autoboil 15 Litre Stainless Steel

325052 Zip Autoboil 25 Litre White

325051 Zip Autoboil 25 Litre Stainless Steel

340052 Zip Autoboil 40 Litre White

340051 Zip Autoboil 40 Litre Stainless Steel

Installation and Operating Instructions

Содержание Autoboil 315052

Страница 1: ...l 15 Litre White 313051 Zip Autoboil 15 Litre Stainless Steel 325052 Zip Autoboil 25 Litre White 325051 Zip Autoboil 25 Litre Stainless Steel 340052 Zip Autoboil 40 Litre White 340051 Zip Autoboil 40...

Страница 2: ...ensory or mental capabilities or lack of expe rience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety For p...

Страница 3: ...heater Frost protection If this heater is located where ambient air temperature could fall below 5 C when the heater is not in use do not turn off the appliance electrically This safeguide does not of...

Страница 4: ...de whether to install with concealed or exposed plumbing and or electrical connections Concealed connections are preferred for superior appearance Step 1 Positioning Position the heater so the tap wil...

Страница 5: ...t the operation of the heater It is recommended that the heater be installed with a stop cock which allows it to be isolated from the mains supply for servicing Water pressure requirements Minimum 70...

Страница 6: ...cable entry gland at the bottom of the unit to the terminal block within the heater Ensure the cable is firmly secured Thread Tape 2 Ensure sufficient thread tape is applied to the thread 1 Fit the co...

Страница 7: ...low into the tank 3 Once the filter flush is complete rotate the valve lever 1800 either way to the FILTERED position Fig 4 Filling Tank 1 Depress the lever as shown in Fig 4 2 Open the tap push the l...

Страница 8: ...n 40 Litre models 60 min 64 min Calibrating Completed 7 When it completes as prompted turn on the mains water supply 8 Select to Continue 9 The home screen will be shown see section 2 1 10 The tank wi...

Страница 9: ...ng Icons and Buttons Move to the next item able to be highlighted Move to the previous item able to be highlighted Confirm menu selection Move to the previous menu Perform one of 3 functions 1 Move to...

Страница 10: ...t Sleep Mode Indication Unit will enter sleep mode at the time shown Unit will enter sleep mode when it is dark All sleep saving modes are disabled 2 2 Sleep Mode Trigger Indication Unit will exit sle...

Страница 11: ...Select on the home screen to navigate to the main menu Choose Settings and select Choose an option and select 2 3 Sleep Override Mode Awake time remaining Unit will return back to sleep mode after th...

Страница 12: ...prevent excessive steam release or high energy usage see section 4 2 3 3 Settings Sleep Modes From the settings menu choose Sleep Modes and select g Choose Sleep Trigger and select and to select the...

Страница 13: ...imer settings for the 2 weekend days simultane ously Adjust on off timer settings for the 7 days separately Weekdays Weekends Individual Days 3 3 3 Timer Settings Individual Days Settings Choose item...

Страница 14: ...u and on the home screen are based on these 2 parameters This action will reset the filter usage counter A re minder is shown to flush the new filter before doing this see page 21 Filter Replacement S...

Страница 15: ...wever the installation environment may have changed requiring recalibration of the boiling point Incorrect boiling calibration points may cause excessive steam vent releases or increased energy usage...

Страница 16: ...t 5 2 Info Current Fault From the info menu choose Current Fault 6 Service Menu Note The service menu is used by technicians only for diagnostic purposes Menu Operation 5 Info Menu Select on the home...

Страница 17: ...333 00 10lt 15lt 25lt 591 00 10lt 15lt ExternalPlumbing ElectricalWiring InternalPlumbing 499 00 40lt 39 50 10lt 15lt 25lt 40lt 459 50 40lt 145 00 10lt 15lt 25lt 458 00 40lt 10 00 10lt 15lt 25lt 40lt...

Страница 18: ...er Head Kit no bracket 17 94612 Mains Inlet Assy 18 93704 0 2 mic Zip Filter Size 2 19 94613 Steam Sensor NTC Item Kit Number Description 20 90501 Tap Top Assy 21 93730 Flow Insert 22 94478 Tap Body 2...

Страница 19: ...805194 09 17 1 02 Page 19 of 24 Exploded View Diagram...

Страница 20: ...ection 3 3 or reset settings from service menu Check power supply Contact Zip authorised agent Runs out of boiling water and fails to refill Outlet tap drips Overflow from vent Excessive steam from ve...

Страница 21: ...y testing between the earth pin on the products lead and a exposed piece of metal on the case and the tap body Error Code Error meaning Solutions 0 Boiling sensor is open circuit Call Zip Service 1 Bo...

Страница 22: ...3 Replace Filter section for details of menu operation Warning Not changing filtration cartridges when required may cause the water to become biologically unsafe If the Zip Autoboil is switched off f...

Страница 23: ...not use strong corrosive spray or abrasive cleaners Clean the case with a soft cloth or sponge and mild soapy water Dispose of the filter cartridge responsibly Use only Zip Filter in this product to e...

Страница 24: ...one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods The...