11
807066 v1.00 03.21 HBP AB Install Instructions
Step 4 – Electrical connection
!
All wiring must be performed by a qualified electrician. Refer to local
relevant electrical codes and guidelines for installation requirements,
cable size and selection to ensure suitability for local installation
conditions and your product’s power rating.
OR
4.1
CLEARANCE
ZONE
CLEARANCE
ZONE
100 min.
3L, 5L, 7.5L models: 65 min.
15L, 25L, 40L models: 150 min.
20 min.
98
COLD WATER
SUPPLY
15L, 25L, 40L
models: 150 min.
Tundish
(optional accessory)
220-240V AC
50Hz power outlet
300
min.
220-240V AC, 50Hz
220-240V AC, 1-phase
4.2
Concealed electrical connection for 15L, 25L,
40L models
(optional for 3L, 5L, 7.5L models)
• If a power cable is fitted, disconnect and
discard.
• Connect a concealed power cable through
the rear access opening to the terminal
block “live” (active) and “neutral” wires,
via the strain relief bush. Tighten the strain
relief bush to secure the cable.
• Crimp a 6.3mm QC female spade
connection to the earth conductor and
attach to the chassis earth male terminal.
• An isolation switch should be installed,
according to AS3000.
• Do not turn power ON until the appliance
can dispense water from the tap outlet.
• Verify the earth continuity.
Exposed electrical connection for 3L, 5L, 7.5L
models
• If a power cable is not already fitted,
connect a cable to the terminal block on
the PCB, via the strain relief bush (cable
gland). Tighten the strain relief bush to
secure the cable.
• With power cable fitted, connect the cable
plug to a 220-240V AC power outlet.
• Do not turn power ON until the appliance
can dispense water from the tap outlet.