background image

Page 6 of 28 

   802411 v3.05 09.20 HT BC Compact Instructions

Important Safety Instructions

This manual contains important safety and installation instructions for the Zip HydroTap G4.

Safety

This appliance is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for their safety. Children should be 

supervised to ensure that they do not play with the appliance.
For products sold in Europe, this appliance can be used by children aged from 8 years and above and 

persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning use of the appliance in a safe way and understand 

the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be 

made by children without supervision.

Refrigerant

The Zip HydroTap unit contains R134A refrigerant under pressure. Maintenance of the refrigeration unit must 

be carried out by an accredited service provider or qualified refrigeration technician.

Qualifications

If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, all 

Installation procedures must be carried out by a suitably qualified tradesperson. The power cable and power 

outlet must be in a safe visible position for connection.

Venting

Sometimes steam and / or condensed droplets may discharge through a vent outlet at the tap. If the tap is not 

installed using the Font pedestal, ensure the tap body is located so the tap outlet safely dispenses into the 

sink bowl area. 

Lifting

Take care when lifting the Zip HydroTap unit. Some units may exceed safe lifting limits. If you feel this is 

beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked 

on the packaging. Do not lift the unit by the front cover or any connections at the top rear of the unit. Refer to 

the technical specification for the weight of your product. 

Airflow

The ambient operating temperatures, when installed in a cupboard, must be between 5ºC -  35ºC. The 

system will operate satisfactorily only if proper air ventilation is provided and only if the recommended air 

gaps of 50mm on each side are provided. See section 2 for correct Installation details. 

Altitude

Water boils at varying temperatures at different altitudes. Your HydroTap adjusts for this during startup 

calibration and will recalibrate itself on a regular basis. 

Frost Protection

If this appliance is located where the ambient air temperature could fall below 5ºC when the heater is not 

in use, do not turn off the appliance electrically. This safeguard does not offer the same protection to the 

connecting pipework and fittings.

!

Содержание 2824AU0W0ZN1C

Страница 1: ...802411 v3 05 09 20 HT BC Compact Instructions Page 1 of 28 Affix Model Number Label Here 802411 BC100 75 range Zip HydroTap G4 Installation and Operating Instructions...

Страница 2: ...ssic All In One Celsius All In One Arc Cube Tap Classic Tap Elite Tap These taps are directly compatible with the HydroTap G4 Command Centre The All In One Tap is a stand alone tap that may be used as...

Страница 3: ...Models 11 2 2 Cupboard Air Circulation 12 STEP 3 Install the Booster Heater if required Section 3 Booster Heater Installation 3 1 Product Description 14 3 2 Installation Procedure 15 3 3 To Remove In...

Страница 4: ...pliance F Check the under counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correc...

Страница 5: ...e units dispense boiling water factory set to 98 C and chilled water factory set to 6 10 C These units are NOT designed to be used for sanitary fixtures The Boiling water units are fitted with a tap m...

Страница 6: ...Installation procedures must be carried out by a suitably qualified tradesperson The power cable and power outlet must be in a safe visible position for connection Venting Sometimes steam and or conde...

Страница 7: ...3500 Electrical Wiring Rules AS NZS 3000 4 This HydroTap product is rated for 230V 50Hz AC operation 5 This unit must be installed with adequate clearances of 50mm on all sides and 200mm above to allo...

Страница 8: ...1 x Inlet vent 1 x Outlet vent 9 x Screws 1 off HydroTap Booster Heater hoses supplied with BCHAV model 1 x Flow Restrictor and Tee piece for Mixer taps and select models 1 x Mixer Tap for 4 In 1 and...

Страница 9: ...0 x 470 x 335 24 All in One BCHA A 100 75 1x10A 2 05 N A 280 x 470 x 335 24 BCHA AV140 75 2x10A 2 05 2 2 280 x 470 x 335 24 Note The Cup measurement 167ml and the Glass measurement 200ml Chilled water...

Страница 10: ...ion point and the stop cock will not be obstructed when the Command Centres are installed For the mains pressure All In One an external hot and cold water supply will be required If an external filtra...

Страница 11: ...y only if the recommend ed air gaps are achieved during installation It is important that the 4mm door buffers are fitted to the inside edge of the cupboard door to allow sufficient air circulation in...

Страница 12: ...tions where the cupboard space temperature is near 35 C or higher the inlet vent See Item B below and silicon buffers need to be fitted If the airflow is still insufficient to maintain normal operatin...

Страница 13: ...vent 1 Mark out and cut the air inlet and door outlet holes as shown 2 Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cupboard space 3 Fit the inlet vent as...

Страница 14: ...40 cups 280mm Note Note 1 water connection Blue marking water in Red marking water out The braided hoses cannot be lengthened Note Note 2 The electrical cable length is 1 0 metre Note Note 3 Position...

Страница 15: ...ns on top of the Booster The hot water outlet hose must be thermally insulated with the insulation provided Tilt Forward Lift UP Release NOTE Remove the backing plate for wall mounting 3 3 To Remove I...

Страница 16: ...ypass Out fitting to the water inlet of the booster unit Marked Blue and from the outlet of the booster unit Marked Red to the Bypass IN fitting on the Zip HydroTap unit Avoid exerting any mechanical...

Страница 17: ...you install a unit determine whether a water softener or an external filter is required 4 1 External Bypass Valve The diverter bypass valve allows the user to choose to have the boiling feed water byp...

Страница 18: ...Min 70mm USB MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT CHILLED OUT Note Mains hose length is 750mm Plug and Cord length is 1800mm Position the Command Centre close to the outle...

Страница 19: ...ains Pressure RED CLEAR BLUE BRAIDED USB MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT CHILLED OUT Note Mains hose length is 750mm Plug and Cord length is 1800mm Position the Comma...

Страница 20: ...nnections BRAIDED BRAIDED BRAIDED BRAIDED Note Mains hose length is 750mm Plug and Cord length is 1800mm Position the Command Centre close to the outlet tap within reach of the hose and cord lengths s...

Страница 21: ...ains hose length is 750mm Plug and Cord length is 1800mm Position the Command Centre close to the outlet tap within reach of the hose and cord lengths supplied Note Note the hoses the hoses need to ha...

Страница 22: ...allow at least 10 litres of water to flush through the filter 4 The product details will be displayed in the screen 5 Once the filter flush is finished turn the stop cock OFF then press Stop to end f...

Страница 23: ...orrect selection for the Booster will affect product performance NOTE Depending on your location you may need to re set the internal clock See section G of the user guide to check and if necessary res...

Страница 24: ...time of the installation All direct natural sun light must be shaded from the HydroTap during the calibration This can be achieved by closing any nearby curtains blinds or by shielding the HydroTap wi...

Страница 25: ...ation Call Zip Service Condenser sensor Open Internal fault Check ventilation Call Zip service Heater fuse driver fault Internal fault Call Zip Service Heater driver fault No hot water Call Zip Servic...

Страница 26: ...v3 05 09 20 HT BC Compact Instructions End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for colle...

Страница 27: ...802411 v3 05 09 20 HT BC Compact Instructions Page 27 of 28 Notes...

Страница 28: ...00 ZIP TAP 1800 947 827 The terms Zip and HydroTap are registered trade marks of Zip Water Aust Pty Ltd Zip products described in this publication are manufactured under one or more patents and furthe...

Отзывы: