Zip 203362 Clage- Hydroboil Скачать руководство пользователя страница 6

Page 6 of 16 

Clage-Zip Hydroboil Electronic - Installation & Operating Instructions - 87490 - June 2009

For concealed plumbing connections, connect the cold water pipe through the 
rear of the chassis using a 15 mm or half-inch capillary elbow. 

Cold water pipes must be flushed before connection to the inlet. Any clogging 
due to sediment or fines will adversely affect the operation of the heater.

The heater must be installed with an isolating valve which allows it to be isolated 
from the mains supply for servicing.

Water pressure requirements:

Minimum - 0.7 bar,  maximum - 7 bar.

Warning: 

If pressure is likely to exceed 7 bar, a pressure limiting valve must be 

installed in the cold water supply line. Clage-Zip recommends a valve rated at 
3.5 bar  for this application.

b) Venting

A vent at the base of the heater must be plumbed to a safe visible location as, 
under certain conditions, it may discharge cold or boiling water and/or steam.

For exposed vent plumbing, connect vent outlet from the base of heater to a 
15 mm or half inch OD pipe which has a continuous fall, is no more than 3 
metres long, has no more than 3 right angle bends, and discharges to a waste 
water drain.

For concealed vent plumbing, direct the vent outlet from the heater rear, using 
a visible tundish. (see diag at left)

c) Electrical

For concealed electrical connection, connect a power cable through the rear 
access opening of the heater to the terminal block within the heater as shown.

For exposed electrical connection, connect the flex and plug (fitted to the 
heater) to a standard power outlet on the wall within 1500 mm of the heater 
that will adequately cater for the units power needs.

Do not turn the power ON until the heater is filled to the tap level, with water.

Step 4 – Assembling

Place the heater case back on to the heater and secure the top 2 case screws. 
Secure two bottom case screws.

Step 5 – Commissioning 

Check previous steps. Turn water supply ON. Water is now flowing into heater, 
check connections for leaks. Wait approximately 5 minutes and check outlet 
tap for water. This is achieved by pressing the tap paddle. 

Power is only to be turned on when water is available from this outlet.

Turn power ON. After a short period, boiling water will be available and will be 
maintained close to boiling point thereafter. Initial heating periods are shown in 
the table on the left.  

250mm

Wring

Concealed

Vent

Concealed

Inlet

45 mm

Visible Tundish

Vent line

Special Note

Ensure the silicon outlet tube is 
correctly positioned within the outlet 
nozzle. Failure to do this may cause 
internal flooding.

Aprox weight when filled

Installation Procedures

 

(continued)

 

Inlet water 
temperature

15°C

10°C

3.0 Litre models

16 min

17 min

5.0 Litre models

16 min

17 min

7.5 Litre models

23 min

24 min

3.0 Litre models 12.5 kg
5.0 Litre models 16.5 kg
7.5 Litre models 20.5 kg

Содержание 203362 Clage- Hydroboil

Страница 1: ...s Clage Zip Hydroboil Electronic Instant boiling water 203362 Clage Zip Hydroboil 3 Litre White 203361 Clage Zip Hydroboil 3 Litre Stainless Steel 205362 Clage Zip Hydroboil 5 Litre White 205361 Clage...

Страница 2: ...ts Contents Read these warnings first 3 Descaling 4 Installation Requirements 4 Installation Procedures 5 6 Step 1 Positioning 5 Step 2 Fastening 5 Step 3 Connecting 6 a Plumbing 6 b Venting 6 c Elect...

Страница 3: ...lay with the heater If the installation site is located more than 1000 metres above sea level the installer should contact a Clage Zip authorised agent for high altitude settings This appliance must b...

Страница 4: ...Unit NOTE When installed with a plug and cord the plug must be accessible c Cold water supply with a minimum working pressure of 70 kPa and a maximum working pressure of 700 kPa connected via an isola...

Страница 5: ...mm left 20 mm right Mark corner positions for the heater on the wall so as to position the paper mounting hole template Step 2 Fastening Position mounting hole template on wall and drill holes where...

Страница 6: ...ical connection connect a power cable through the rear access opening of the heater to the terminal block within the heater as shown For exposed electrical connection connect the flex and plug fitted...

Страница 7: ...is crossed out wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made...

Страница 8: ...eam Internal adjustment Contact Clage Zip authorised agent Warning this appliance must be earthed Following remedial service the earthing continuity of the heater must be checked by a qualified techni...

Страница 9: ...l until it latches in the closed position and the unlocked indicator is illuminated Warning The unit is now capable of dispensing boiling water without the safety feature Dispensing Boiling water Clag...

Страница 10: ...uld be configured as follows The Electronic Hydroboil has a real time clock that operates in 24 hour mode and can have 2 ON OFF times per day If the user selects either of the energy saver modes see b...

Страница 11: ...the unit goes into energy saver mode and will allow the temperature of the stored water to drop to and be maintained at 65 C As soon as the ambient light rises above 100lux the Hydroboil returns to f...

Страница 12: ...parameter press CSS1 SET DAY OF THE WEEK To return to Normal Mode press CSS4 To step to the next day of the week press either CSS2 or CSS3 To step to the next configuration parameter press CSS1 SET F...

Страница 13: ...ured as on pressing CSS1 will return the user to Normal Operation Note 3 If both Sleep Mode and Low Light sensor is configured as off the user will be able to use ON OFF mode SUN ON TIME 1 To return t...

Страница 14: ...Hot Tank Kit 13 90579 Overload Kit 14 90732 Tap Handle Kit 15 90733 Outlet Nozzle Kit 16 90503 Strap and Key Kit 3Litre Hydroboil 16 90504 Strap and Key Kit 5L 7 5Litre Hydroboil 17 90505 Tap Nut Kit...

Страница 15: ...Clage Zip Hydroboil Electronic Installation Operating Instructions 87490 June 2009 Page 15 of 16 Spare Parts 1 2 3 4 5 6 7 3 8 9 10 11 14 15 27 16 17 18 19 20 21 23 26 24 25 12 13 22 28...

Страница 16: ...o specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods CLAGE GmbH Postfach 1680 D 21306 L neburg Pirolweg...