background image

3

1. 

IMPORTANT INFORMATION

1.1 

IMPORTANT SAFETY NOTES

♦ Please read all instructions before installing and operating this product.
♦ Please keep all instructions for later reference.
♦ Please follow all warnings and instructions marked on the product.
♦ For safety reason, when device is being powered on, this product should NOT be installed in any 

electric socket which makes the surface with venting holes on the product to face downward (facing 
the floor).

♦ Unplug the Powerline device from the wall outlet before cleaning. Use a dry cloth for cleaning. DO 

NOT use liquid cleaners or aerosol cleaners.

♦ DO NOT operates this product near water.
♦ This product should never be placed near or over a radiator, or heat register.
♦ This product relies on the building’s electrical installation for short-circuit (over current) protection.
♦ DO NOT allow anything to rest on the product interconnect plug. DO NOT locates this product where 

people may walk on the cords.

♦ Because this product sends data over the power line, it is recommended that you plug directly into a 

power outlet. Do not plug the Device into a UPS or power strip with surge protection. The product 
has its own power filter for protection against surges.

♦ Only a qualified technician should service this product. Opening or removing covers may result in 

exposure to dangerous voltage points or other risks.

♦ Unplug the product from the wall outlet and refer the product to qualified service personnel for the 

following conditions:

▪ When the interconnect cords are damaged or frayed.
▪ If liquid has been spilled into the product.
▪ If the product has been exposed to rain or water.
▪ If the product does not operate normally when the operating instructions are followed.
▪ If the product exhibits a distinct change in performance.

The Device is intended for connection to the AC power line. For installation instructions, refer to the 

Installation section. The following precautions should be taken when using this product.

Содержание PWQ-5101C

Страница 1: ...Powerline Wireless N Extender User s Manual ...

Страница 2: ...EATE AN ENCRYPTED PLC NETWORK GROUP 4 2 4 3 REMOVE DEVICE FROM AN EXISTING NETWORK GROUP 4 4 CREATE ADDITIONAL ENCRYPTED NETWORK 6 SPECIFICATIONS 3 3 4 5 5 5 6 8 8 9 9 10 5 1 LOGIN TO SETTING PAGE 5 2 DUPLICATE CURRENT SSID PASSWORD WITH ONE BUTTON 11 13 10 10 14 5 ADVANCED WI FI SETTINGS VIA WEB BROWER 11 Table of Content FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT JOIN TO AN ENCRYPT...

Страница 3: ... plug DO NOT locates this product where people may walk on the cords Because this product sends data over the power line it is recommended that you plug directly into a power outlet Do not plug the Device into a UPS or power strip with surge protection The product has its own power filter for protection against surges Only a qualified technician should service this product Opening or removing cove...

Страница 4: ...be co located or operating in conjunction with any other antenna or transmitter End users and installers must be provide with antenna installation instructions and trans mitter operating conditions for satisfying RF exposure compliance Canada Industry Canada IC Notices This Class B digital apparatus complies with Canadian ICES 003 and RSS 210 Operation is subject to the following two conditions 1 ...

Страница 5: ...actory default Power LED Ethernet Link Act LED PLC LED Power LED PLC LED WLAN Link Act LED Ethernet Link Act LED ON Linked w other PLC device Green Wi Fi is encrypted Red Wi Fi is not encrypted Press to join an encrypted Wi Fi network Clone AP Button Press to duplicate current Wi Fi network Press 1 3 secs to join an encrypted PLC network Press over 10 secs to create the encrypted PLC network Press...

Страница 6: ...They are too far to communicate or it is alone in its logical network ON Ethernet connection detected Blinking Network traffic in transaction OFF No Ethernet connection detected Press 10 seconds Randomly generate a new PLC network group name Press 2 to 3 seconds Start paring with the other PLC device Paring procedure keeps for 2 minutes or ends automatically when they are paired It can be stopped ...

Страница 7: ...on with security protection Steady Red Wi Fi network without security protection Flash Red Wi Fi network traffic in transaction without security protection Blinking Green 0 5 sec ON 0 5 sec OFF WPS negotiation OFF Wi Fi disabled ON Ethernet connection detected Blinking Network traffic in transaction OFF No Ethernet connection detected WPS Clone AP negotiation Press 10 seconds Randomly generate a n...

Страница 8: ...adband modem with an Ethernet cable provided Plug the PLC Wi Fi Extender to AC outlet and place it in a location you wish to extend Wi Fi access Step 1 Step 2 Search Wi Fi network and connect it with WPA PSK default password The default Wi Fi password appears on the product label Step 3 Modem Router PC Smartphone Tablet ...

Страница 9: ...o do so please follow below steps GROUP button GROUP button Press GROUP button on both adapters over 10 secs until LED light turns off and on at once to generate new encrypted PLC network PLC LED light will be off Press GROUP button of adapter A again for 1 3 sec to start pairing procedure Power LED will start blinking Press GROUP button of adapter B for 1 3 sec to start pairing procedure Power LE...

Страница 10: ...create additional private network for your powerline devices that co existence with your existing powerline private network group please repeat the Step 1 2 to generate new private network group for selected powerline devices P S Users can press the RESET button to reset the network name back to its factory default Simply follow step 1 to generate new PLC group name for PLC adapter Afterward follo...

Страница 11: ...mobile s IP address Go to Network Connections Local Area Connection Connection Status and choose the Internet Protocol TCP IP and click on Properties Enter IP address such as 192 168 2 XXX XXX can be set from 1 128 and click OK Go to Settings Wi Fi Selected SSID advanced settings then click on Static to enter IP address such as 192 168 2 XXX XXX can be set from 1 128 and Subnet Mask 55 255 255 0 G...

Страница 12: ...d password fields The Powerline Wireless N Extender setting page will show up after successfully login Note After the setup process is completed DO NOT forget to set the PC or mobile device s IP address back to the original settings DHCP for web surfing Mobile device iOS Mobile device Android Note you can change user name and password in Administration tab ...

Страница 13: ... LED will start blinking Press WPS button on the router and Powerline Wi Fi extender will duplicate current Wi Fi SSID and password from the router The extender will reboot once procedure is completed SSID OOO Password XXX SSID OOO Password XXX Clone APbutton Default funtion WPS To switch between WPS and Clone AP please login to Advanced Wi Fi Setting via web browser Make sure WPS button has been ...

Страница 14: ...ased IPTV streams Transmission Distance Maximum Supported Devices in a network group Active Total Regulation AR7420 LAN 10 100 Base TX PLC HomePlugAV 1 1 IEEE 1901 PHY Rate up to 500Mbps TCP Rate up to 95Mbps UDP Rate up to 95Mbps 2 28 MHz 30 68 MHz 128 bit AES w Key management 1 port 10 100 Ethernet 0 40 C 10 85 non condensing 100 240 VAC 50 60 Hz Full Load 2 4W Standby Mode 0 5W Custom 67 5 x 56...

Страница 15: ...upported Devices in a network group Active Total Regulation AR7420 AR9331 WLAN IEEE 802 11 b g n PLC HomePlug AV 1 1 LAN 10 100 Based TX Ethernet WLAN to Ethernet up to 93 Mbps WLAN to PLC up to 90 Mbps PLC to Ethernet up to 95 Mbps TCP WLAN 2 4 2 4835 GHz PLC 2 28 MHz 30 68 MHz WLAN WPS and PIN code WPA PSK WPA2 PSK PLC 128 bit AES 1 port 10 100 Ethernet 0 40 C 10 85 non condensing 100 240 VAC 50...

Отзывы: