Where there are enough optical fibres in an existing multimode optical fibre backbone cable to allow the allocation of a
569
complete cable to the ZinWave 2700 DAS then the backbone panel at the FD/HC may be replaced with a ZinWave
570
Splice Panel as shown in Figure 4-8. The latter enables a lower channel insertion loss (see 4.3.3) and more secure
571
distribution of the services provided over the ZinWave 2700 DAS. It is also the preferred approach if additional backbone
572
cabling is to be installed (see 4.3.1.4).
573
574
However, unless another ZinWave Splice Panel is used at the BD/IC (as part of a campus distribution system) the optical
575
fibre cable at the BD/IC will require:
576
•
the re-termination of the optical fibres using appropriate hi-conn pigtails of Table 3-8;
577
•
the replacement of the backbone panel adaptors with their singlemode equivalents.
578
579
WARNING:
Customers may be unwilling to allow partial re-work to be undertaken on a backbone cabling panel if other services are
580
already operating though the optical fibre contained within it.
581
582
WARNING:
Installers may be unwilling to accept responsibility for the modifications made to existing cable plant. The opening of
583
backbone panels may:
584
a)
be difficult due to poor cable dressing practice in the cabinets that puts both the re-work and other cabling at risk;
585
b)
determine that inadequate lengths of optical fibre exist in the panels to allow fusion splicing of the ZinWave hi-conn
586
pigtails;
587
c)
determine that the management practices for the optical fibre within the panels puts other optical fibres at risk.
588
589
Where existing backbone cables are to be used for the distribution of the ZinWave 2700 DAS, the optical fibre in the
590
ZinWave TO cables (see Table 3-9), launch cords, hi-conn pigtails and patchcords (see Table 3-8), shall be selected to
591
match those of the backbone cable.
592
593
594
Zinwave TO cable
Optical fibre management
MMF optical fibre cable:
building backbone
Fusion spliced Zinwave hi-conn MMF pigtail
Optical fibre management
Fusion spliced Zinwave hi-conn MMF pigtail
Zinwave Hi-conn MMF cord
Duplex LC - backbone panel
SMF adaptors on panels
ZinWave
Termination Panel
Backbone
Termination Panel
595
596
Figure 4-7: Re-use of existing multimode optical fibre backbone cabling at an FD/HC via patching
597
598