Zinko ZPE-35RH-1M Скачать руководство пользователя страница 2

2

Instructions Before Use

1. Inspection of all components for shipping damage or oil leakage. If any shipping damage is found, notify carrier at

    once. Shipping damage is not covered by warranty. The carrier is responsible for all repair or replacement costs

    resulting from damage in shipment.
2.                          

Oil feeding plugs

 (Code No.5) are always shut tightly when in shipment and even in use because

                             the tanks are completely enclosed. Use them together with quick couplers with check valves.
3.                          

Check your power supply.

 Power supply is AC110V or 220V 50/60Hz single phase. Make sure

                             that a grounded outlet or a plug adapter with a grounding attachment must be used.
4.                          

Check hydraulic oil. 

Always check oil level before operation with the connected cylinders fully

                             retracted (extend if pull cylinders). In case oil is added with cylinders fully extended and then

    cylinders are retracted, the returned oil will overflow in the reservoirs causing generation of high pressure in the

    reservoirs. Verify required oil volume in a reservoir as follows:

    a) Retract the connected cylinder fully.

    b) Pull power plug out.

    c) Turn oil feeding plug counterclockwise and remove it.

    d) Clean the oil gauge of the removed oil feeding plug with a piece of cloth and put it in the oil feeding port again to

        check oil level. BE CAREFUL WITH THE O-RING.

!

!

WARNING

!

WARNING

!

CAUTION

!

Description of Components

4.

33

10.63

.39 Ø .16

4.

15

.3

9

Ø

 4

.3

 4

.7

2)

5.

31

12.68 (15.75)

6.

97

 (7

.4

4)

2.

32

1.65

4.09

1. Oil Plug

2. Reservoir

3. Pump

4. Motor

5. Electric Cord

6. Switch

7. Handle

8. Release Valve

9. Output: 3/8" NPT

Specifications

*Remarks: 2L (usable oil: 1.6L) reservoir pumps are also available.

Model #

Electric Motor

Reservoir

Weight

1st Stage 2nd Stage 1st Stage 2nd Stage

70

0.6

0.3

Capacity 

1.0L 

Usable 

0.8L

17 lb.

Commutator and 

open type, 

0.35KW 110V or 

220V 50/60Hz 

single phase, "E" 

type insulation 

2000rpm

ZPE-35RH-

1M(L)

Hydraulic Pump

Maximum Work 

Pressure Mpa

Flow Rate L/min(50Hz)

Zinko Hydraulic Jack

Models: ZPE-35RH-1M & ZPE-35RH-1MB

Содержание ZPE-35RH-1M

Страница 1: ...ture which can cause trouble in hydraulic equipment 3 In the case pumps are used outdoors in extremely cold regions exchange oil for hydraulic oil with the proper viscosity Increased viscosity due to a drop in oil temperature may cause equipment to function improperly CAUTION Cautions When Installing Pump Install a pump unit for better balance Since the reservoirs of totally enclosed rubber struct...

Страница 2: ... will overflow in the reservoirs causing generation of high pressure in the reservoirs Verify required oil volume in a reservoir as follows a Retract the connected cylinder fully b Pull power plug out c Turn oil feeding plug counterclockwise and remove it d Clean the oil gauge of the removed oil feeding plug with a piece of cloth and put it in the oil feeding port again to check oil level BE CAREF...

Страница 3: ...return position b Do not fill with even a small quantity of replensihment of different kinds of oil c Be careful that impurities or foreign matter do not enter into new oil Oil Safety Notes When oil enters into the eyes wash it away fully with clean water and consult a doctor immediately In case oil enters into an open wound wash it away with soapy water and quickly consult a doctor CAUTION WARNIN...

Страница 4: ...ul with air accumulation in the system To remove air a Make sure the tank is full with oil Open the oil supply cork on the upper part of the pump check the quantity of oil and carry out until full b When oil does not come out or pressure does not rise when a return valve is opened push the button on the operation switch about 10 times and perform air omission of the pump c Air may accumulate in th...

Страница 5: ... Stopper Screw 1 13 Thrust Washer 4 5 Lock Screw 1 14 Set Screw 1 4 6 Handle 1 15 Set Screw 2 4 7 Spring Pin 1 16 Blind Rubber Plug 1 17 Leg Stay 5 1 Rubber Tank 1 18 Fitting Bolt 5 2 Tank Cover 5 3 Leg Stay 2 1 High Press Piston 5 4 Rubber Leg 2 2 Spring 2 3 Copper Packing 6 1 Power Cord 2 4 Blind Cover 6 2 Protection Tube 2 5 Screw 1 6 3 Pendant Switch 2 6 Spring 6 4 Cord Clip 2 7 Steel Ball 6 5...

Страница 6: ...defective power cord plug 3 Defective switches 4 Worn carbon brushes 5 Defective motor 6 Defective remote switch 7 Unit is not plugged in 1 Check line voltage 2 Replace defective part 3 Check switches 4 Replace carbon brushes see page 4 5 Repair or replace motor 6 Repair or replace switch 7 Plug in unit Abnormal Noise From Motor 1 Damage to pump or motor 2 Damage of ball bearings etc 1 Repair or r...

Отзывы: