Zinko ZPE-35RH-1M Скачать руководство пользователя страница 1

1

Power Supply

The power supply is AC110V or 220V 50/60Hz single phase.

 Make sure your line voltage is compatible with your pump.

The wrong voltage connection or voltage drop of your line will cause burning or heating.

1. BE CAREFUL ABOUT VOLTAGE DROP WHEN USED WITH AN ELECTRIC GENERATOR.

2. When the power supply is disconnected, ALWAYS GRASP THE POWER PLUG AND PULL IT OUT. Disconnect by 

    grasping the cord and pulling it out will cause breaking of a wire or a short circuit.

3. When a supplement cord is used, use only three-wire grounded cords of such sufficient gauge as 1.25mm

2

 or more 

    with a maximum length of 10M. This will help to avoid voltage drop or damage of the solenoid valves or the electric 

    motor.

CAUTION

!

!

Using the Pump

Be Sure to Take Appropriate Safety Measures

When hydraulic equipment is operated, protect yourself with a personal safeguard, working clothes and shoes, safety

glasses, etc.

Always Check Pressure Limitations of the Hydraulic Circuit

Always confirm in advance that maximum permissible working pressure of a hydraulic pump is lower than the pressure

rating of the lowest rated component connected in the system.

1. BE CAREFUL TO AVOID ELECTRIC SHOCK. Do not pull power plug out with a wet hand. Use a grounded outlet or a 

    plug adapter with a grounding attachment in order to protect the operator from electric shock.

2. DO NOT OPERATE PUMP BY THE SIDE OF AN ELECTRIC WELDER.

3. DO NOT PLACE THE PUMP ON EARTHED MATERIALS OR EQUIPMENT.

WARNING

!

1. DO NOT USE PUMP IN THE RAIN OR ON/IN WET AND DUSTY PLACES.

2. DO NOT EXPOSE HYDRAULIC SYSTEM TO THE DIRECT RAYS OF THE SUN. Be careful with unacceptable rise in 

    hydraulic oil temperature, which can cause trouble in hydraulic equipment.

3. In the case pumps are used outdoors in extremely cold regions, exchange oil for hydraulic oil with the proper viscosity. 

    Increased viscosity due to a drop in oil temperature may cause equipment to function improperly.

CAUTION

!

Cautions When Installing Pump

Install a pump unit for better balance

Since the reservoirs of totally enclosed rubber structures are used in these series of pumps, the pumps can be placed for

use in any position (slanted, inverted, or perpendicular). However, the pumps should be installed on stable places. When

a pump is used aslant, make sure it is firmly affixed to prevent sliding which may result in damage or personal injury.

Prepare a suitable working environment

Make sure all system components are protected from external sources of damage such as excessive heat, flame, moving

machine parts, sharp edges, or corrosive chemicals.

Caution Remarks Used In This Manual

DANGER

!

WARNING

!

CAUTION

!

As a result of incorrect use and/or disregard of this remark, imminent danger may occur resulting in

serious injury or death.

As a result of incorrect use and/or disregard of this remark could cause serious injury or death.

As a result of incorrect use and/or disregard of this remark, there is a possibility that an operator may

receive an injury or material damage may occur.

Safety Information 

Read and follow all WARNINGS, CAUTIONS and INSTRUCTIONS included with each product to use the product correctly

and to avoid personal injury or property damage during system operation. 

ZINKO

 will not be held responsible for damage

or injury resulting from unsafe use of products, lack of maintenance or incorrect system application.

Operation & Maintenance Manual

Toll Free: 

1-800-579-8088  

Web:

 

www.zinko.com

ZINKO

H y d r a u l i c   J a c k

M O D E L S

ZPE-35RH-1M & ZPE-35RH-1MB

Electric/Hydraulic Pumps

Содержание ZPE-35RH-1M

Страница 1: ...ture which can cause trouble in hydraulic equipment 3 In the case pumps are used outdoors in extremely cold regions exchange oil for hydraulic oil with the proper viscosity Increased viscosity due to a drop in oil temperature may cause equipment to function improperly CAUTION Cautions When Installing Pump Install a pump unit for better balance Since the reservoirs of totally enclosed rubber struct...

Страница 2: ... will overflow in the reservoirs causing generation of high pressure in the reservoirs Verify required oil volume in a reservoir as follows a Retract the connected cylinder fully b Pull power plug out c Turn oil feeding plug counterclockwise and remove it d Clean the oil gauge of the removed oil feeding plug with a piece of cloth and put it in the oil feeding port again to check oil level BE CAREF...

Страница 3: ...return position b Do not fill with even a small quantity of replensihment of different kinds of oil c Be careful that impurities or foreign matter do not enter into new oil Oil Safety Notes When oil enters into the eyes wash it away fully with clean water and consult a doctor immediately In case oil enters into an open wound wash it away with soapy water and quickly consult a doctor CAUTION WARNIN...

Страница 4: ...ul with air accumulation in the system To remove air a Make sure the tank is full with oil Open the oil supply cork on the upper part of the pump check the quantity of oil and carry out until full b When oil does not come out or pressure does not rise when a return valve is opened push the button on the operation switch about 10 times and perform air omission of the pump c Air may accumulate in th...

Страница 5: ... Stopper Screw 1 13 Thrust Washer 4 5 Lock Screw 1 14 Set Screw 1 4 6 Handle 1 15 Set Screw 2 4 7 Spring Pin 1 16 Blind Rubber Plug 1 17 Leg Stay 5 1 Rubber Tank 1 18 Fitting Bolt 5 2 Tank Cover 5 3 Leg Stay 2 1 High Press Piston 5 4 Rubber Leg 2 2 Spring 2 3 Copper Packing 6 1 Power Cord 2 4 Blind Cover 6 2 Protection Tube 2 5 Screw 1 6 3 Pendant Switch 2 6 Spring 6 4 Cord Clip 2 7 Steel Ball 6 5...

Страница 6: ...defective power cord plug 3 Defective switches 4 Worn carbon brushes 5 Defective motor 6 Defective remote switch 7 Unit is not plugged in 1 Check line voltage 2 Replace defective part 3 Check switches 4 Replace carbon brushes see page 4 5 Repair or replace motor 6 Repair or replace switch 7 Plug in unit Abnormal Noise From Motor 1 Damage to pump or motor 2 Damage of ball bearings etc 1 Repair or r...