18
10.2.1 Mounting LWR50F-00-04-A and LWR50F-00-05-A
Activation is done via SCM or a commercially available IO-Link master with Port Class B.
pin Color
Function
Explanation
3
2
1
4
5
M12, 5-pin Connector/bracket
1
Brown
+ 24 V DC sensor
IO-Link communication supply
2
White
+ 24 V DC actuator
Actuator supply voltage
3
Blue
GND sensor
0 V actuator supply voltage
4
Black
C/Q
IO-Link communication
5
Gray
GND actuator
0 V actuator supply voltage
10.2.2 Mounting LWR50F-01-03-A
The selected fixed part is equipped with an
integrated Smart Communication Module
(SCM) with RS485 interface.
pin Color
Function
Explanation
6
1
2
4
8
3
5
7
M8, 8-pin Socket/bracket
1
White
signal
RS485+
2
Brown
signal
RS485-
3
Green
Output 2
Connect signal: 24 V if loose part is coupled.
4
Yellow
Output 1
Freedrive signal: 24 V if Freedrive button is
pressed.
5
Gray
+ 24 V DC
+ 24 V DC supply voltage
6
Pink
Input 1
7
Blue
Input 2
8
Red
GND
0 V supply voltage
INSTALLATION AND OPERATION INSTRUCTIONS:
LWR50F
DDOC01074 / b
EN / 2021-09-15
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com