INSTALLATION AND OPERATING INSTRUCTIONS:
HM1000 series magnetic gripper
Zimmer GmbH
●
Im Salmenkopf 5
●
77866 Rheinau, Germany
●
Phone: +49 7844 9138-0
●
Fax: +49 7844 9138-80
●
www.zimmer-group.de
DDOC00184
deu / 1/21/2019 / 0
5. Installation
1234
► The dimensions for a particular mounting piece
2
can be taken from the
drawings on the product data sheets.
The product data sheets and CAD data are available on our website,
www.zimmer-group.de
, in all common data formats
The drawing to the right shows the HM1078 as an example
The mounting piece
2
shown to the right is a ball joint and is
available as an accessory matching the gripper
► Observe the permitted tightening torque (
see Tab. Technical data
)
► The gripper is aligned on the mounting piece using a centering disk
3
that
matches the gripper and is also available as an accessory.
► Establish the pneumatic connection (
see Tab. Technical data
)
Information:
The HM1030 gripper is unique. Due to its small size, it is mounted and connected
to the pneumatic system by a central, threaded Ø M10 stem, which also contains a
pneumatic ØM5 connection.
5.1
Installation of HM1030
*1) Please always compare the technical data with the corresponding tables on the Internet at
www.zimmer-group.de
!
*1)
HM1030NC HM1046NC HM1078NC HM1097NC
Adhesive force (for 0 mm air gap, high surface quality
)
N
27
65
220
450
Min./max. operating pressure
bar
3 / 8
Min./max. operating temperature
°C
+5 / +80
Pneumatic connection
M5
M5
G1/8"
G1/8"
Cylinder volume per cycle
cm³
3.5
9
75
250
Weight
kg
0.06
0.28
1.2
2.2
Ø pitch circle mounting holes
Ø
-
30
45
60
Mounting screws, quality 8.8
mm
-
3 x M5x7
3 x M8x9
3 x M10x15
Permitted tightening torque
N
-
6.03
24.93
49.45
Ø centering hole for centering disk
Ø
-
10H7
15H7
20H7
Threaded stem
Ø
M10 x 13.5
-
-
-
4. Technical data