10.6 Installing the support structure
CAUTION

Risk of injury from collision

 

Make sure that when the product is moving, the support structure does not collide with other parts of the 

machine in which the product is installed.

NOTICE

This customer-specific support structure must be designed such that it does not impede the movement of the 

gripper jaws.
Dimension A may not be exceeded by the support structure.
Dimension B may be exceeded by the support structure.

 

For the dimensions required for the customer-specific support structure, refer to the technical data sheet 

found on our website.

INFORMATION

GPD5000 series: You cannot install an additional support structure if a pressure piece is installed on the product.

It is possible to remove the cover plate in order 

to use a customer-specific support structure. 

For installing a support structure, there are 

additional fits under the cover plate.

3

1

2

1

Dimension B

2

Dimension A

3

Cover plate

10.7 Installing accessories

NOTICE

 

Before installing an accessory, make sure it is suitable for use with the selected variant.

 

You can find information on our website.

 

Please contact Zimmer Customer Service if you have any questions.

INSTALLATION AND OPERATING INSTRUCTIONS:

GPP5000, GPD5000

DDOC00196 / m

EN / 2023-06-05

Zimmer GmbH • Im Salmenkopf 5 • 

 77866 Rheinau, Germany • 

 +49 7844 9138 0 • www.zimmer-group.com

Содержание GPP5025N-00-A

Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS 2 jaw parallel gripper pneumatic GPP5000 3 jaw concentric gripper pneumatic GPD5000 DDOC00196 THE KNOW HOW FACTORY www zimmer group com...

Страница 2: ......

Страница 3: ...storage preservation 8 10 Installation 9 10 1 Installing GPP5000 10 10 2 Installing GPD5000 11 10 3 Installing the energy supply 12 10 4 Installing the sensors 13 10 4 1 Adjusting the magnetic field s...

Страница 4: ...these dangers The warning symbols are assigned according to the type of danger WARNING This notice warns of a situation that is potentially hazardous to personal health Ignoring these notices can caus...

Страница 5: ...oduct under extreme conditions such as aggressive fluids or abrasive dusts Additional drilled holes or threads Zimmer GmbH shall accept no liability for any damage caused by improper use The operator...

Страница 6: ...derstood everything Observe country specific accident prevention regulations and the general safety notices The following qualifications are a prerequisite for performing various work on the product 4...

Страница 7: ...kinematics producing the gripper jaw movement For products with gripping force retention this supports the grip force acting in the force transfer direction GPP5000 GPD5000 1 1 1 Gripper jaw 7 Technic...

Страница 8: ...that no unexpected movements can occur Before commissioning the product and after transport check all power and communication connections as well as all mechanical connections If the product is stored...

Страница 9: ...power supply against being switched on unintentionally Check the machine for any residual energy that may be present For spring assisted products wait until the gripper jaws reach the end position wi...

Страница 10: ...Observe the tightening torque of the mounting screws Verify the permitted load capacity of the required screw connections in accordance with VDI 2230 10 1 Installing GPP5000 The product can be instal...

Страница 11: ...se the straight pins to position the product on the mounting piece Mount the product on the mounting piece using the appropriate mounting screws 1 Mounting screw 2 Straight pins INSTALLATION AND OPERA...

Страница 12: ...ecessary ordering information can also be found there Use compressed air in accordance with DIN ISO 8573 1 4 4 4 Insert the screw fittings into the provided connections 1 1 1 Connector INFORMATION Mul...

Страница 13: ...For information on optional accessories and those included in the scope of delivery refer to our website The sensors can detect any desired position of the gripper jaws directly at the mechanical sys...

Страница 14: ...on our website Please contact Zimmer Customer Service if you have any questions Assembly requirements Strength class DIN EN ISO 4762 GPP5000 8 8 GPD5000 12 9 1 Mounting screw 2 Gripper finger 3 Center...

Страница 15: ...ound on our website INFORMATION GPD5000 series You cannot install an additional support structure if a pressure piece is installed on the product It is possible to remove the cover plate in order to u...

Страница 16: ...en the gripper jaws are opening there is a risk of impact in the guide area CAUTION Material damage resulting from blowing out with compressed air Blowing out the product with compressed air can cause...

Страница 17: ...or contamination Have maintenance work be performed by Zimmer Customer Service whenever possible Dismantling and reassembling the product without authorization may result in complications as special...

Страница 18: ...that the specific technical documents were produced in accordance with Annex VII Part B of this Directive We undertake to provide the market supervisory bodies with electronic versions of special doc...

Отзывы: