Step
18.
Apply
power
to
the
luminaries.
Step
19.
Associate
the
ZAURA
Virtual
Dimming
Starters
to
the
Master
by
pressing
the
Associate
Dimmer
button.
The
Master
will
attempt
association
for
a
period
of
30
seconds.
Step
20.
Verify
the
association
of
all
ZAURA
Virtual
Dimming
Starters:
a. Change
the
mode
to
Toggle
Dimming
Lamps
by
sliding
DIP
Switch
2
to
the
ON
position.
b. Press
the
Set
Mode
button.
All
luminaries
that
are
associated
as
Virtual
Dimming
should
turn
off.
c. Press
the
Set
Mode
button
a
second
time.
The
same
luminar
‐
ies
should
turn
back
on.
d. Slide
DIP
Switch
2
to
the
OFF
position
to
return
the
Master
to
Normal
Operating
Mode.
Step
21.
To
set
the
Standard
Luminaries
to
be
controlled
by
the
Master,
remove
power
and
replace
the
original
starters
with
ZAURA
Starters
in
the
remaining
luminaries
to
be
controlled
by
the
Master.
For
assistance,
refer
to
the
figure
in
Step
17
.
Step
22.
Apply
power
to
the
luminaries.
Step
23.
Associate
the
ZAURA
Starters
to
the
Master
by
pressing
the
Associate
Non
‐
Dimmer
button
on
the
Master.
The
Master
will
attempt
association
for
a
period
of
30
seconds.
Step
24.
Verify
the
association
of
all
ZAURA
Starters:
a. Change
the
mode
to
Toggle
All
Lamps
by
sliding
DIP
Switch
3
to
the
ON
position.
b. Press
the
Set
Mode
button.
All
luminaries,
including
the
Vir
‐
tual
Dimming
luminaries
installed
in
the
previous
step,
should
turn
off.
c. Press
the
Set
Mode
button
again.
The
same
luminaries
should
turn
back
on.
d. Slide
DIP
Switch
3
to
the
OFF
position
to
return
the
master
to
Normal
Operating
Mode.
Step
26.
Place
the
Detector
body
into
the
base
plate
so
that
the
arrows
on
each
are
aligned.
Turn
the
unit
clockwise
to
latch
it
closed;
the
arrows
will
offset
each
other.Insert
and
fasten
the
retaining
screw.
Step
27.
Mount
the
Range
Extenders
(if
any)
to
their
designated
base
plates;
see
steps
25
and
26.
Your
installation
is
now
complete!
DO
NOT
USE
THIS
PRODUCT
IN
LIFE
SUPPORT
SYSTEMS.
LIFE
SUPPORT
POLICY
ZILOG’S
PRODUCTS
ARE
NOT
AUTHORIZED
FOR
USE
AS
CRITICAL
COMPONENTS
IN
LIFE
SUP
‐
PORT
DEVICES
OR
SYSTEMS
WITHOUT
THE
EXPRESS
PRIOR
WRITTEN
APPROVAL
OF
THE
PRESI
‐
DENT
AND
GENERAL
COUNSEL
OF
ZILOG
CORPORATION.
Life
support
devices
or
systems
are
devices
which
(a)
are
intended
for
surgical
implant
into
the
body,
or
(b)
support
or
sustain
life
and
whose
failure
to
perform
when
properly
used
in
accor
‐
dance
with
instructions
for
use
provided
in
the
labeling
can
be
reasonably
expected
to
result
in
a
significant
injury
to
the
user.
A
critical
component
is
any
component
in
a
life
support
device
or
system
whose
failure
to
perform
can
be
reasonably
expected
to
cause
the
failure
of
the
life
sup
‐
port
device
or
system
or
to
affect
its
safety
or
effectiveness.
©2011
Zilog,
Inc.
All
rights
reserved.
Information
in
this
publication
concerning
the
devices,
applications,
or
technology
described
is
intended
to
suggest
possible
uses
and
superseded.
ZILOG,
INC.
DOES
NOT
ASSUME
LIABILITY
FOR
OR
PROVIDE
A
REPRESENTATION
OF
ACCURACY
OF
THE
INFORMATION,
DEVICES,
OR
TECHNOLOGY
DESCRIBED
IN
THIS
DOCUMENT.
ZILOG
ALSO
DOES
NOT
ASSUME
LIABILITY
FOR
INTELLECTUAL
PROPERTY
INFRINGEMENT
RELATED
IN
ANY
MANNER
TO
USE
OF
INFORMATION,
DEVICES,
OR
TECHNOLOGY
DESCRIBED
HEREIN
OR
OTHER
‐
WISE.
The
information
contained
within
this
document
has
been
verified
according
to
the
gen
‐
eral
principles
of
electrical
and
mechanical
engineering.
ZAURA
is
a
trademark
of
Zilog,
Inc.
All
other
product
or
service
names
are
the
property
of
their
respective
owners.
Step
17.
To
set
Virtual
Dimming
Luminaries,
remove
power
and
replace
the
original
starters
with
ZAURA
Starters.
If
no
Virtual
Dimming
luminaries
are
required,
skip
to
Step
21
.
For
a
more
thorough
description
of
virtual
dimming,
see
the
section
titled
Light
Sensor
for
Daylight
Harvesting
in
the
ZAURA
Installation
Guide.
Step
25.
Mount
the
Master
to
the
previously
‐
installed
base
plate
closest
to
the
center
of
the
room
by
placing
the
four
tabs
of
the
lens
cover
into
the
matching
notches
of
the
Detector
body
and
turning
the
lens
cover
clockwise
until
it
is
secure.
Warning: