background image

ZAURA

 

RF

 

Wireless

 

Lighting

 

Control

Quick

 

Start

 

Guide

QS008001

0311

Page

 

3

 

of

 

3

Step

 

18.

 

Apply

 

power

 

to

 

the

 

luminaries.

Step

 

19.

 

Associate

 

the

 

ZAURA

 

Virtual

 

Dimming

 

Starters

 

to

 

the

Master

 

by

 

pressing

 

the

 

Associate

 

Dimmer

 

button.

 

The

 

Master

 

will

attempt

 

association

 

for

 

a

 

period

 

of

 

30

 

seconds.

Step

 

20.

 

Verify

 

the

 

association

 

of

 

all

 

ZAURA

 

Virtual

 

Dimming

Starters:

a. Change

 

the

 

mode

 

to

 

Toggle

 

Dimming

 

Lamps

 

by

 

sliding

 

DIP

 

Switch

 

2

 

to

 

the

 

ON

 

position.

b. Press

 

the

 

Set

 

Mode

 

button.

 

All

 

luminaries

 

that

 

are

 

associated

 

as

 

Virtual

 

Dimming

 

should

 

turn

 

off.

c. Press

 

the

 

Set

 

Mode

 

button

 

a

 

second

 

time.

  

The

 

same

 

luminar

ies

 

should

 

turn

 

back

 

on.

d. Slide

 

DIP

 

Switch

 

2

 

to

 

the

 

OFF

 

position

 

to

 

return

 

the

 

Master

 

to

 

Normal

 

Operating

 

Mode.

Step

 

21.

 

To

 

set

 

the

 

Standard

 

Luminaries

 

to

 

be

 

controlled

 

by

 

the

Master,

 

remove

 

power

 

and

 

replace

 

the

 

original

 

starters

 

with

 

ZAURA

Starters

 

in

 

the

 

remaining

 

luminaries

 

to

 

be

 

controlled

 

by

 

the

 

Master.

For

 

assistance,

 

refer

 

to

 

the

 

figure

 

in

 

Step

 

17

.

Step

 

22.

 

Apply

 

power

 

to

 

the

 

luminaries.

Step

 

23.

 

Associate

 

the

 

ZAURA

 

Starters

 

to

 

the

 

Master

 

by

 

pressing

the

 

Associate

 

Non

Dimmer

 

button

 

on

 

the

 

Master.

  

The

 

Master

 

will

attempt

 

association

 

for

 

a

 

period

 

of

 

30

 

seconds.

Step

 

24.

 

Verify

 

the

 

association

 

of

 

all

 

ZAURA

 

Starters:

a. Change

 

the

 

mode

 

to

 

Toggle

 

All

 

Lamps

 

by

 

sliding

 

DIP

 

Switch

 

3

 

to

 

the

 

ON

 

position.

b. Press

 

the

 

Set

 

Mode

 

button.

 

All

 

luminaries,

 

including

 

the

 

Vir

tual

 

Dimming

 

luminaries

 

installed

 

in

 

the

 

previous

 

step,

 

should

 

turn

 

off.

c. Press

 

the

 

Set

 

Mode

 

button

 

again.

 

The

 

same

 

luminaries

 

should

 

turn

 

back

 

on.

d. Slide

 

DIP

 

Switch

 

3

 

to

 

the

 

OFF

 

position

 

to

 

return

 

the

 

master

 

to

 

Normal

 

Operating

 

Mode.

Step

 

26.

 

Place

 

the

 

Detector

 

body

 

into

 

the

 

base

 

plate

 

so

 

that

 

the

arrows

 

on

 

each

 

are

 

aligned.

 

Turn

 

the

 

unit

 

clockwise

 

to

 

latch

 

it

closed;

 

the

 

arrows

 

will

 

offset

 

each

 

other.Insert

 

and

 

fasten

 

the

retaining

 

screw.

Step

 

27.

 

Mount

 

the

 

Range

 

Extenders

 

(if

 

any)

 

to

 

their

 

designated

base

 

plates;

 

see

 

steps

 

25

 

and

 

26.

 

Your

 

installation

 

is

 

now

 

complete!

DO

 

NOT

 

USE

 

THIS

 

PRODUCT

 

IN

 

LIFE

 

SUPPORT

 

SYSTEMS.

LIFE

 

SUPPORT

 

POLICY

ZILOG’S

 

PRODUCTS

 

ARE

 

NOT

 

AUTHORIZED

 

FOR

 

USE

 

AS

 

CRITICAL

 

COMPONENTS

 

IN

 

LIFE

 

SUP

PORT

 

DEVICES

 

OR

 

SYSTEMS

 

WITHOUT

 

THE

 

EXPRESS

 

PRIOR

 

WRITTEN

 

APPROVAL

 

OF

 

THE

 

PRESI

DENT

 

AND

 

GENERAL

 

COUNSEL

 

OF

 

ZILOG

 

CORPORATION.

 

Life

 

support

 

devices

 

or

 

systems

 

are

 

devices

 

which

 

(a)

 

are

 

intended

 

for

 

surgical

 

implant

 

into

 

the

body,

 

or

 

(b)

 

support

 

or

 

sustain

 

life

 

and

 

whose

 

failure

 

to

 

perform

 

when

 

properly

 

used

 

in

 

accor

dance

 

with

 

instructions

 

for

 

use

 

provided

 

in

 

the

 

labeling

 

can

 

be

 

reasonably

 

expected

 

to

 

result

 

in

a

 

significant

 

injury

 

to

 

the

 

user.

 

A

 

critical

 

component

 

is

 

any

 

component

 

in

 

a

 

life

 

support

 

device

 

or

system

 

whose

 

failure

 

to

 

perform

 

can

 

be

 

reasonably

 

expected

 

to

 

cause

 

the

 

failure

 

of

 

the

 

life

 

sup

port

 

device

 

or

 

system

 

or

 

to

 

affect

 

its

 

safety

 

or

 

effectiveness.

©2011

 

Zilog,

 

Inc.

 

All

 

rights

 

reserved.

 

Information

 

in

 

this

 

publication

 

concerning

 

the

 

devices,

applications,

 

or

 

technology

 

described

 

is

 

intended

 

to

 

suggest

 

possible

 

uses

 

and

 

superseded.

ZILOG,

 

INC.

 

DOES

 

NOT

 

ASSUME

 

LIABILITY

 

FOR

 

OR

 

PROVIDE

 

A

 

REPRESENTATION

 

OF

 

ACCURACY

OF

 

THE

 

INFORMATION,

 

DEVICES,

 

OR

 

TECHNOLOGY

 

DESCRIBED

 

IN

 

THIS

 

DOCUMENT.

 

ZILOG

 

ALSO

DOES

 

NOT

 

ASSUME

 

LIABILITY

 

FOR

 

INTELLECTUAL

 

PROPERTY

 

INFRINGEMENT

 

RELATED

 

IN

 

ANY

MANNER

 

TO

 

USE

 

OF

 

INFORMATION,

 

DEVICES,

 

OR

 

TECHNOLOGY

 

DESCRIBED

 

HEREIN

 

OR

 

OTHER

WISE.

 

The

 

information

 

contained

 

within

 

this

 

document

 

has

 

been

 

verified

 

according

 

to

 

the

 

gen

eral

 

principles

 

of

 

electrical

 

and

 

mechanical

 

engineering.

 

ZAURA

 

is

 

a

 

trademark

 

of

 

Zilog,

 

Inc.

 

All

 

other

 

product

 

or

 

service

 

names

 

are

 

the

 

property

 

of

 

their

respective

 

owners.

Step

 

17.

 

To

 

set

 

Virtual

 

Dimming

 

Luminaries,

 

remove

 

power

 

and

replace

 

the

 

original

 

starters

 

with

 

ZAURA

 

Starters.

 

If

 

no

 

Virtual

Dimming

 

luminaries

 

are

 

required,

 

skip

 

to

 

Step

 

21

.

 

For

 

a

 

more

thorough

 

description

 

of

 

virtual

 

dimming,

 

see

 

the

 

section

 

titled

 

Light

Sensor

 

for

 

Daylight

 

Harvesting

 

in

 

the

 

ZAURA

 

Installation

 

Guide.

 

Step

 

25.

 

Mount

 

the

 

Master

 

to

 

the

 

previously

installed

 

base

 

plate

closest

 

to

 

the

 

center

 

of

 

the

 

room

 

by

 

placing

 

the

 

four

 

tabs

 

of

 

the

 

lens

cover

 

into

 

the

 

matching

 

notches

 

of

 

the

 

Detector

 

body

 

and

 

turning

the

 

lens

 

cover

 

clockwise

 

until

 

it

 

is

 

secure.

 

Warning: