zika MIG500 Скачать руководство пользователя страница 4

 

OWNER’S MANUAL                                                                    - 3 -                                                                         

 

MACHINE DESCRIPTION 

MIG350IJ  CO

gas  shielded  welding  machines  of  our  company  are  inverter  welding  machines  manufactured  by  our 

company applying most advanced inversion technology in the world.   

Their  principle  is  to  commutate  the  power  frequency  of  50Hz/60Hz  into  direct  current,  and  then  utilize  the  high-power 

device  IGBT  to  invert  it  into  high  frequency  (15KHz/16KHz),  then  reduce  the  voltage  and  commutate,  and  output 

high-power D.C power supply via Pulse Width Modulation (PWM). Since the switch power inversion technology is adopted, 

the weight and volume of the welding machine is brought down greatly with a conversion efficiency increase of more than 

30%. Characteristic: stable wire feed rate, little splatter, portable, energy-saving, low electromagnetic noise. 

The  CO

2

  gas  shielded  welding  machine  of  our  company  is  equipped  with  unique  electronic  reactor  circuit,  precisely 

controlling  the  short-circuiting  transfer  and  mixed  transfer  of  welding,  producing  excellent  welding  characteristic. 

Compared  with  silicon  controlled  welding machine and  welder  with  taps,  our  products  have  the  following  merits: stable 

wire  feed  rate,  portable,  energy-saving,  electromagnetic noise  free.  Besides,  our  products  have  merits  such  as  electric 

network  fluctuation  self-compensation  function,  little  splatter,  good  arc  starting,  deep  welding  pool,  high  duty  cycle  etc. 

This  equipment  can  be  applicable  in  large-scale  plants  such  as  shipyards,  steel  structure  plants  etc.  featuring  high 

efficiency and energy-saving.   

The CO

2

 gas shielded welding machine of our company has function of ending arc On/Off. Arc starting current and ending 

arc current can be adjusted separately, being very applicable for automatic welding. This machine is most suitable for the 

welding of mild steel, alloy steel and stainless steel.   

Thank  your  for  choosing  our  products.  Please  feel  free  to  propose  your  valuable  suggestions;  we  will  make  efforts  to 

perfect our products and service.

   

 

WARNING

 

The machine is mainly used in industry. It will produce radio wave, so the worker should make   

fully preparation for protection. 

 

 

 

 

 

 

 

 

Содержание MIG500

Страница 1: ...ZIKA OWNER S MANUAL MIG500...

Страница 2: ...lation instruction 5 6 Panel function instruction 8 7 Welding parameter recommendation 10 8 Notes or prevention measures 11 9 Questions to be run into during welding 12 10 Maintenance 12 11 Daily chec...

Страница 3: ...s Harmful to your eyes burn your skin Wear suitable protective mask light filter and protective garment to protect eyes and body Prepare suitable protective mask or curtain to protect looker on Fire W...

Страница 4: ...ed transfer of welding producing excellent welding characteristic Compared with silicon controlled welding machine and welder with taps our products have the following merits stable wire feed rate por...

Страница 5: ...rent adjustment A 80 500 35 500 Output voltage V MMA 40 MIG 39 Duty cycle 60 Power factor 0 93 Efficiency 85 Type of wire feeder Panasonic interface Wire feed speed m min 3 15 Post flow time S 1 5 0 5...

Страница 6: ...of the wire feeder select different wire feeding groove according to the welding wire diameter 7 Loosen the pressure arm feed the welding wire into wire feeding pipe through gadget wheel and groove P...

Страница 7: ...OWNER S MANUAL 6 Explanatory drawing for Installation of MIG 500...

Страница 8: ...olid core conversion function When the switch is in the solid core position CO2 gas welding wire is used When the switch is in the flux cored position self shielded welding wire is applied 3 Gas purge...

Страница 9: ...er 3 Crater voltage adjustment 4 Abnormal indicator 5 Power indicator 6 Arc trait adjustment 7 Crater current adjustment 8 Flux core sold wire switch 9 Wire diameter selection 10 Gas purge switch 11 P...

Страница 10: ...2 26 60 0 2 24 4 2 26 6 4 45 5 5 50 0 1 15 5 1 15 5 2 20 0 1 1 2 2 1 1 2 2 1 1 6 6 2 22 20 0 2 26 60 0 2 24 4 2 26 6 4 45 5 5 50 0 1 15 5 1 15 5 2 20 0 1 1 2 2 1 1 2 2 1 1 6 6 3 30 00 0 3 34 40 0 3 32...

Страница 11: ...5 4 40 0 2 25 5 2 20 0 2 25 5 H H i i g g h h w w e e l l d d i i n n g g s s p p e e e e d d 1 1 0 0 0 0 8 8 0 0 9 9 4 45 50 0 1 14 40 0 1 19 9 2 20 0 1 16 60 0 1 10 0 1 15 5 1 1 2 2 0 0 8 8 0 0 9 9...

Страница 12: ...e the working area is adequately ventilated It is important for the performance and the longevity of the machine 2 Do not over load The operator should remember to watch the max duty current Response...

Страница 13: ...ance such as oil dirt rust paint etc on the base metal MAINTENANCE WARNING The power shall be cut off completely before all maintenance overhaul works Make sure to pull out power plug before opening t...

Страница 14: ...xtended part too small the arc will be unstable Wire diameter and the tube inner diameter match or not Reason of unstable arc please use the suitable tube Partial winding and extended Reason of poor w...

Страница 15: ...and wearing out of pressed wire the narrowing of its contact surface Lead to unstable arc and wire sending Position Checking keys Remarks Torch cable 1 If torch cable over bended 2 If the metal connec...

Страница 16: ...n of Abnormal items on up right of the list please inspect and maintain for the corresponding items which have mark in the column according to the following list respectively Earlier Checking Diagram...

Страница 17: ...re feeding pipe and cable diameter Worn blocked up or deformation etc Body of weld gun 1 Loose connection of conductive tip nozzle and nozzle contactor 2 Contactor of weld gun body is not plunged in o...

Страница 18: ...failure Contact to us for repairing Replace the cable The wire feeding circuit is damaged Contact to us for repairing The wire feeder does not work Press the manual switch examine whether there is air...

Страница 19: ...or welding A failure in auxiliary power component of control board Please contact with the dealer or the factory Abnormity Indicator lamp on Power Indicator lamp on Air fan operates normally 1 IGBT da...

Отзывы: