background image

38 

 

 

 

 

Appendix

 

Infrared (IR) Protocol 

Toggle Null Modem 

Description: Reverses the TX and RX lines of the RS-232 DB9 Connector. 
Command: 0x30 Pronto Hex: 

0000 006C 0000 0022 0156 00ab 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015  

0015 0015 0015 0015 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015 0015 003f 0015 

003f 0015 003f 0015 003f 0015 0015 0015 0015 0015 0015 0015 0015 0015 003f 0015 003f  

0015 0015 0015 0015 0015 003f 0015 003f 0015 003f 0015 003f 0015 0015 0015 0015 0015  

003f 0015 003f 0015 1d0b 

Scale Up 

 

Description: Activate up-scaling Command: 
0x40 Pronto Hex: 
0000 006C 0000 0022 0156 00ab 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015  

0015 0015 0015 0015 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015 0015 003f 0015 003f 
0015 003f 0015 003f 0015 0015 0015 0015 0015 0015 0015 0015 0015 0015 0015 0015 

0015 003f 0015 0015 0015 003f 0015 003f 0015 003f 0015 003f 0015 003f 0015 003f 0015 0015 0015 
003f 0015 1d0b 

Scale Down 

Description: Activate down-scaling Command: 
0x41 Pronto Hex: 
0000 006C 0000 0022 0156 00ab 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015  

0015 0015 0015 0015 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015 0015 003f 0015 003f 
0015 003f 0015 003f 0015 003f 0015 0015 0015 0015 0015 0015 0015 0015 0015 0015  

0015 003f 0015 0015 0015 0015 0015 003f 0015 003f 0015 003f 0015 003f 0015 003f 0015  

0015 0015 003f 0015 1d0b 

 

Содержание SW-42Plus

Страница 1: ...1 Zigen SW 42Plus 4 x 2 HDMI Switch 4K 60 Hz 4 4 4 HDCP 2 2 Auto Switching ZigNet Full Web Interface and System Diagnostics...

Страница 2: ...ctric shock and or damage to this product never handle or touch this unit or power cord if your hands are wet or damp Do not expose this product to rain or moisture 7 Unplug this apparatus during ligh...

Страница 3: ...acturer defect Zigen will repair or replace the product to ensure that it meets original performance specifications Reduced performance due to normal wear and tear or damages caused by misuse or negli...

Страница 4: ...ed with the distribution 3 The name of the author may not be used to endorse or promote products derived from this software without specific prior written permission This Software is provided by the a...

Страница 5: ...en Technical Support Tel 818 654 5252 Fax 818 654 5355 9 00AM 5 00PM PST Email info zigencorp com Web www zigencorp com Mailing Address Zigen Corp c o Customer Service 16135 Wyandotte Street Lake Balb...

Страница 6: ...2 1 4 and Auto Switching Independent Up and Down Scaling EDID Management Video Diagnostics Humidity Temperature Monitoring Hot Plug Full Web Interface and System Diagnostics Advanced EDID management S...

Страница 7: ...Control 1x CR2025 Lithium Cell 3V Battery 1x Quick Start Guide If any of these products are not present upon first opening of the package please contact Zigen or your dealer 2017 Zigen Corp All Rights...

Страница 8: ...ecting ZigNet 17 Accessing ZigNet 18 RS 232 Configuration 19 Telnet IP Configuration 20 System Control Using ZigNet Full Web Interface System Diagnostics Introduction to ZigNet 21 Navigation Bar 22 Co...

Страница 9: ...ed based on the selected output Flashing behaviors may occur for alert and diagnostic purposes 3 Select The Select button along with the HDMI Indicators display the input that is routed to the selecte...

Страница 10: ...resolutions The Zigen locking HDMI cable is recommended 3 SETUP DIP switches provide overrides for defaults or prior system settings See page 7 for details 4 IR IN Connect an IR extender or electrical...

Страница 11: ...down 1 ON OFF Button Press these buttons to toggle between the operating modes 2 Input Buttons 1 4 Press these buttons to select the desired input for the selected output Each button corresponds to a...

Страница 12: ...back panel of the unit The Zigen locking HDMI cable is recommended for a sturdy connection The HDMI cable can then be connected in any of the following ways Connect the HDMI cable to an Ultra HD displ...

Страница 13: ...13 Application Diagram sample Get Started...

Страница 14: ...flash simultaneously if a fault condition is detected IR Sensor The IR sensor shown on the Front Panel accepts infared commands from the included remote control device Select The Select button along...

Страница 15: ...witches DIP switch explanations from left to right 1 DIP 1 is force Hot Plug Detect HPD enable To enable set switch to down position 2 DIP 2 is inactive 3 DIP 3 is downstream EDID control To disable s...

Страница 16: ...sors will be used to receive IR signals 2 Each numbered button on the IR remote control unit represents an input Press the desired source button on the IR remote control to switch to that input 3 Pres...

Страница 17: ...ng to ZigNet Connection Access Network Setup Option 1 Connect the unit and a computer into a router or switch Network Setup Option 2 Connect a computer directly into the unit by using an Ethernet cros...

Страница 18: ...n a web browser of your choice and insert the given IP address in the address bar Optional for Windows users Skip steps 1 3 and type in the host name which is displayed on the bottom of the unit Requi...

Страница 19: ...232 port on the back of the SW 42Plus to a computer using an RS 232 cable 2 Open a hyperterminal app of your choice Putty recommended on a computer 3 Enter default settings shown below Baud Rate 11520...

Страница 20: ...k or with a crossover cable See page 9 for more information 2 Open a Telnet client application of your choice Putty recommended on a computer 3 Enter the IP address or host name of your SW 42Plus See...

Страница 21: ...ection between a personal computer on a local area network or a connection directly to the Ethernet connector on the back panel of the unit The following is the Welcome page requesting login informati...

Страница 22: ...the page is selected Control Page Allows the user to switch the inputs for the outputs change EDID settings and adjust audio settings Diagnostics Page Allows the user to monitor video signals and syst...

Страница 23: ...le at the sink New EDID Use the three drop down menus to select a new EDID configuration and press Set EDID Custom EDID Press Browse to upload a custom EDID configuration Select your custom EDID file...

Страница 24: ...ol Using ZigNet Diagnostics Page Diagnostics displays the status and parameters of the HDMI Input Outputs and the disposition of the system See appendix for Diagnostics Specifications pg 31 for detail...

Страница 25: ...25 System Control Using ZigNet Email Alert Page The Email Alert page allows full customization of system notifications Toggle between specific alerts and choose the frequency of notifications...

Страница 26: ...mode when no IP address can be obtained Settings will take place after reset IP Mode The IP mode allows selecting between DHCP and Static IP mode Firmware Select browse to upload firmware updates Sel...

Страница 27: ...27 System Control Using ZigNet Admin Page Change Passeord To change the password type the current password the desired new password and confirm the new password...

Страница 28: ...om of your unit To address a cluster of SW 42Plus units use only xxxx without serial numbers Note These commands can be combined like so SW42 xxxx st uptime version Powering Device Command Example To...

Страница 29: ...tom of your unit To address a cluster of SW 41Plus units use only xxxx without serial numbers Note These commands can be combined like so SW42 xxxx st uptime version Powering Device Command Example To...

Страница 30: ...P Control 1 x 9 pin RS 232 port 1 x 3 5mm IR In Port 1 x IR Sensor In 1 x 12 VDC Locking Connector Temperature Operating 32 122 F 0 50 C Humidity 20 90 non condensing Dimensions 0 86 x 3 70 x 10 76 in...

Страница 31: ...ntire 18 Gb s of bandwidth Chroma Subsampling 4 4 4 4 2 2 4 2 0 See note above chroma subsampling or color compression is related to bit depth and video resolution settings with regard to total bandwi...

Страница 32: ...2 or 16 bit 3D Video Format Displays the 3D video format packing Audio Frequency Displays the audio frequency 32 44 1 48 etc Audio Word Length Display the length of the audio sample 16 20 or 24 bits A...

Страница 33: ...imedia Interface is a proprietary audio video interface for transmitting video data and audio data HDR High Dynamic Range refers to a technique in imaging to reproduce a greater range of luminosity HP...

Страница 34: ...GB 4 4 4 RGB 4 4 4 RGB 4 4 4 4 2 2 RGB 4 4 4 4K 25 4K 30 4k 50 RGB 4 4 4 4 2 0 4 2 0 4 2 2 4 2 0 4 2 0 4K 60 Appendix Glossary HDMI 2 0 4K Specifications The table below specifies the only combination...

Страница 35: ...015 0015 0015 0015 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015 0015 003f 0015 003f 0015 003f 0015 003f 0015 0015 0015 0015 0015 0015 0015 0015 0015 0015 0015 003f 0015 0015 0015 0015 0015 003f 0...

Страница 36: ...0156 00ab 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015 0015 0015 0015 0015 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015 0015 003f 0015 003f 0015 003f 0015 003f 0015 003f 0015 003f 0015 0015...

Страница 37: ...0156 00ab 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015 0015 0015 0015 0015 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015 0015 003f 0015 003f 0015 003f 0015 003f 0015 0015 0015 003f 0015 003f...

Страница 38: ...0000 0022 0156 00ab 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015 0015 0015 0015 0015 0015 0015 0015 003f 0015 0015 0015 003f 0015 0015 0015 003f 0015 003f 0015 003f 0015 003f 0015 0015 0015 0015...

Страница 39: ...15 0015 0015 0015 0015 0015 0015 0015 0015 003f 0015 003f 0015 0015 0015 0015 0015 003f 0015 003f 0015 003f 0015 1d0b Power On Description Sets the unit in normal mode Command 0x12 Pronto Hex 0000 006...

Страница 40: ...40 Revision B 2017 8 25 1 HDMI 2 0 4k Specifications Chart 2 ZigNet Email Alert Notifications 3 RS 232 Telnet command additions Revision B 2018 5 21 4 Infrared IR Protocol Appendix Revision History...