12
Using the IR Remote
Get
St
art
ed
Inputs
Input channel selection buttons, same with the corresponding front panel buttons
Outputs
Output channel selection buttons, same with the corresponding front panel buttons
Menu
ALL
:
Select all inputs/outputs.
To connect an input to all outputs:
Example: Input 1 to all Outputs:
→ Press INPUTS 1 + ALL + ENTER
EDID
:
1)
One input port learns the EDID data from one output port.
Example: Input 2 learns EDID data from output 4:
→ Press EDID + INPUTS 2 + OUTPUTS 4+ ENTER
2)
All input ports learn EDID data from one output port.
Example: All input ports learn EDID data from output 3:
→ Press EDID + ALL + OUTPUTS 3 + ENTER
CLEAR
: Withdraw button.
ENTER