![Zigen HAX-44/HDBT Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/zigen/hax-44-hdbt/hax-44-hdbt_user-manual_933757016.webp)
16 ZIG-HAX-44/HDBT USER MANUAL
Command Syntax
RS-232 & IP Commands
–
note the same commands are available via RS-
232 and IP
–
use @ for RS232, nothing for IP.
RS-232
@HAX-44/HDBT-XXXX(last 4 of SN)
<sp> <parameter> <sp>... <parameter>
<sp> <end of response>
Default RS232 Protocol Settings (can be changed in WebOS if required):
Baud Rate = 115200 Data Bits = 8
Parity = None
Stop Bit = 1
Flow control = None
IP
DA14-XXXX
<sp> <parameter> <sp>... <parameter> <sp> <end of response>
Commands (shown in RS-232 format):
Help
@HAX-44/HDBT-XXXX help
Shows a list of available commands
Disco
@HAX-44/HDBT-XXXX disco
Uptime
@HAX-44/HDBT-XXXX uptime
Shows day, hours, minutes and seconds the HAX-44/HDBT has been running.