NOTE:

Users would better NOT enroll multiple Zone devices at the same time to prevent registration failure.

5.7. HeartBeat Technique

In a security system, it is important that Zone devices report the conditions to the central security unit (the
CIE device). To meet this need, Netvox came up with a technique called “

HeartBeat

”.

Right after Z312 enrolls to a security system, it sends a HeartBeat signal to the CIE device. Afterward, it will
send HeartBeat data regularly. HeartBeat period supports 30 seconds~168 hours.

5.8. Battery

1. Working voltage of Z312 is between 2.1-3.6V.
2.Once Z312 is joined into ZigBee network successfully, the battery voltage will be detected
immediately. And then battery voltage will be detected once every hour; voltage detection will be
carried out when the button is pressed. Once the voltage is less than 2.1V, Z312 will make
warning once every hour. Z312 will make low voltage announcement to all the device in the
same network, in the mean time, the red indicator flashes once.

3. Default low-voltage threshold:
BatteryVoltageMinThreshold: 2.1V (0x15)
BatteryVoltageThreshold1: 2.2V (0x16)
BatteryVoltageThreshold2: 2.3V (0x17)
BatteryVoltageThreshold13: 2.4V (0x18)
4. When the voltage is lower than BatteryVoltageMinThreshold, it will issue alarmcode = 0x10
the alarm broadcast command;
When the voltage is lower than BatteryVoltageThreshold1, it will issue alarmcode = 0x11 the
alarm broadcast command;
When the voltage is lower than BatteryVoltageThreshold2, it will issue alarmcode = 0x12 the
alarm broadcast command;
When the voltage is lower than BatteryVoltageThreshold3, it will issue alarmcode = 0x13 the
alarm broadcast command.

5.9. Restore to Factory Setting

While Z312 is unable to communicate with its enrolled CIE device or users would like Z312 to join a new
network, a factory reset is required. To restore it to factory setting, please follow the steps:

Step1. Press and hold both

Auxiliary Key

and

Binding Key

for 5 seconds.

Step2. Until the indicator starts flashing

red

quickly, release both buttons to complete the reset.

Step3. After 20 flashes, Z312 will go into the turn-off mode.

Содержание Z312

Страница 1: ...ZigBeeTM Door Bell User Manual Door Bell Model Z312 Firmware V4 0 Hardware V1 1 Door Bell Series...

Страница 2: ...urn Off Z312 6 5 2 Join the ZigBee Network 6 5 3 Binding 6 5 4 Sleeping Mode 7 5 5 Wake up Z312 7 5 6 Enroll in the ZigBee Security System 7 5 7 HeartBeat Technique 8 5 8 Battery 8 5 9 Restore to Fact...

Страница 3: ...door bell button What is ZigBee ZigBee is a short range wireless transmission technology based on IEEE802 15 4 standard and supports multiple network topologies such as point to point point to multip...

Страница 4: ...4 2 Product Appearance Doorbell Button Indicator Red Green Battery Cover Binding Key Auxiliary Key...

Страница 5: ...on Battery life may vary based on operating conditions 4 Installation Z312 is powered using two 3V CR2450 button cell batteries Please follow the instructions for installation Step1 Remove the battery...

Страница 6: ...time NOTE2 After Z312 first time joins a network or re installs the batteries it will be activated for 5 minutes 5 2 Join the ZigBee Network After Z312 is powered on it will search for an existing Zig...

Страница 7: ...would consume up to 30 times power spending compared to normal operating status To prevent this unwanted power consumption we recommend that users remove the batteries to power off the device 5 5 Wake...

Страница 8: ...twork in the mean time the red indicator flashes once 3 Default low voltage threshold BatteryVoltageMinThreshold 2 1V 0x15 BatteryVoltageThreshold1 2 2V 0x16 BatteryVoltageThreshold2 2 3V 0x17 Battery...

Страница 9: ...table Min Interval Unit second Max Interval Unit second Reportable Change Change rate Reportable Change Change rate Reportable Change 1 65534 1 65534 0 To report per Minimum interval To report per Ma...

Страница 10: ...c 0x0000 Identify 0x0003 Identify 0x0003 IAS ACE 0x0501 Commissioning 0x0015 IAS WD 0x0502 IAS Zone 0x0500 power configure 0x0001 Diagnostics Information 0x0B05 Poll Control 0x0020 This lists the attr...

Страница 11: ...0 16 bytes Read write O 0x0011 PhysicalEnvironment 8 bit Enumeration 0x00 0xff Read write 0x00 O 0x0012 DeviceEnab Boolean 0x00 0x01 Read write 0x01 M 7 Netvox App Control Interface 1 After joining in...

Страница 12: ...n configurate other selection as shown below 3 In the basic information interface will show status of Z312 which is currently registered to CIE security control center including default Heart Beat car...

Страница 13: ...lick EP1 into the basic information interface by clicking on the bottom of the Basic Information Settings About Device interface to switch interfaces to check detail information of the device As shown...

Страница 14: ...ures High temperatures may damage the device or battery Do not use or store the device in extremely cold temperatures When the device warms to its normal temperature moisture can form inside the devic...

Отзывы: