ZIGBEE SRAC-23B-ZBS Скачать руководство пользователя страница 3

 

3

complete device removal. Factory Reset function will clear the device of its stored setting 
information and prompt the Siren to search for new ZigBee network.   

Before removing device, make sure the Siren is within current ZigBee network signal range 

1.  Press and hold the function button for 10 seconds, then release the button to reset Siren. 
2.  Upon reset, the Siren will clear current ZigBee network setting and transmit signal to ZigBee 

coordinator to remove itself from current ZigBee network. It will then actively search for 
available ZigBee network again and join the network automatically.   

 

ZigBee Router Device Capacity (SRAC-23B-ZBSR) 

The Siren model with Router function (SRAC-23B-ZBSR) allows other ZigBee devices to join the 
ZigBee Network through the Router. It has maximum capacity of 40 ZigBee devices or routers 

 

Appendix 

(For developers only.)

 

 

Indoor Siren Cluster ID 

Device ID: IAS Warning Device: 0x0403 
Endpoint: 0x01 

Server Side 

Client Side 

Mandatory 

Basic (0x0000) 

None 

Identify(0x0003)  

IAS Zone(0x0500) 

 

IAS WD(0x0502) 

 

Optional 

None 

None 

 

Attribute of Basic Cluster Information 

Identifier Name 

Type 

Range 

Access

Default 

Mandatory 

/ Optional

0x0000 

ZCLVersion 

Unsigned 

8-bit integer

0x00 – 0xff

Read 

only 

0x01 M 

0x0001 

ApplicationVersion 

Unsigned 

8-bit integer

0x00 – 0xff

Read 

only 

0x00 O 

0x0003 

HWVersion 

Unsigned 

8-bit integer

0x00 –0xff 

Read 

only 

0 O 

0x0004 

ManufacturerName 

Character 

String 

0 – 32 bytes

Read 

only 

Climax 

Technology 

0x0005 

ModelIdentifier 

Character 

String 

0 – 32 bytes

Read 

only 

(Model Version) 

 

0x0006 

DateCode 

Character 

String 

0 – 16 bytes

Read 

only 

 

0x0007 

PowerSource 

8-bit 0x00 

–0xff 

Read 

only 

 M 

0x0010 

LocationDescription 

Character 

String 

0 – 32 bytes

Read / 

Write 

 O 

0x0011 

PhysicalEnvironment 

8-bit 0x00 

–0xff 

Read / 

Write 

0x00 O 

0x0012 

DeviceEnabled 

Boolean 0x00 

–0x01

Read / 

Write 

0x01 M 

 

Attribute of Identify Cluster Information 

Identifier Name 

Type 

Range 

Access

Default 

Mandatory 

/ Optional

0x0000 

IdentifyTime 

Unsigned 

16-bit integer

0x00 –0xffff

Read / 

Write 

0x0000 M 

 

Attribute of IAS Zone Cluster Information 

Identifier Name 

Type Range 

Access

Default 

Mandatory 

/ Optional

0x0001 

ZoneState 

8-bit 

Enumeration

All 

Read 

only 

0x00 M 

0x0002 

ZoneType 

8-bit 

Enumeration

All 

Read 

only 

 M 

Содержание SRAC-23B-ZBS

Страница 1: ...ry and ZigBee network router function Model No Rechargeable Battery ZigBee Router SRAC 23 ZBS No No SRAC 23B ZBS Yes No SRAC 23B ZBSR Yes Yes Parts Identification 1 Function Button LED Indicator Function Button Usage Press once to send a supervision signal Press and hold the button for 10 seconds then release to reset the Indoor Siren Press and hold the button for 3 seconds to change indication be...

Страница 2: ...tandard ZigBee allows a large amount of devices to be included in a network and coordinated for data exchange and signal transmission Due to the fundamental structure of ZigBee network ZigBee device will actively seek and join network after powering on Since performing a task in connecting network may consume some power it is required to follow the instructions to avoid draining battery of a ZigBe...

Страница 3: ...S Zone 0x0500 IAS WD 0x0502 Optional None None Attribute of Basic Cluster Information Identifier Name Type Range Access Default Mandatory Optional 0x0000 ZCLVersion Unsigned 8 bit integer 0x00 0xff Read only 0x01 M 0x0001 ApplicationVersion Unsigned 8 bit integer 0x00 0xff Read only 0x00 O 0x0003 HWVersion Unsigned 8 bit integer 0x00 0xff Read only 0 O 0x0004 ManufacturerName Character String 0 32...

Страница 4: ...elocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution To assure continued compliance any changes or modifications not expressly approved by the party responsible for compliance could...

Отзывы: