background image

ZAIoT-VTC01

3

1. Product Description

ZAIoT-VTC01 is a low-power design, plug-and-play wireless vibration and
temperature integrated collection terminal product, with high-precision
vibration acceleration and temperature collection functions. The product
has built-in 10kHz (Z-axis) and 6kHz (XY-axis) high-frequency response
acceleration and temperature sensors. By carrying the ZETA high-speed
protocol, the original waveform can be transmitted while ensuring
wide-coverage

communication

performance, and the effective

communication line-of-sight is greater than 800 meters. Powered by a
large-capacity lithium sub-battery, it can work continuously for 3 years at
a typical transmission interval (6h). At the same time, the product has
built-in end-side analysis and AI alarm algorithms, and can flexibly
configure various combination strategies of original waveform and feature
edge calculation to meet the needs of multiple use scenarios. The product
complies with IEC 60079 intrinsically safe explosion-proof standard, the
explosion-proof mark is Ex ia IIC T4 Ga, and the operating environment
temperature is -20℃~+60℃. Suitable for industrial and chemical
scenarios.

Suitable for general rotating equipment application scenarios: motors,
bearings, pumps, fans, air compressors, gearboxes...

Three-axis vib temperature monitoring, supporting 10000Hz high
frequency vibration eigen waveform monitoring.

Support for synchronous acquisition between different nodes to meet
applications with synchronous monitoring requirements.

Supports multiple installation methods, plug and play, rapid deployment

ZETA network wireless transmission and deployment, low cost, wide
coverage, stable connection, local deployable

Low power consumption design, battery powered life of approximately 3
years (default configuration)

Web platform and mobile client APP support, view data and track device
status anytime, anywhere

Содержание ZETA ZAIoT-VTC01

Страница 1: ...ZAIoT VTC01 1 ZETA Edge AI Vibration Sensor ZAIoT VTC01...

Страница 2: ...ting Instructions 8 5 1 Platform login 8 5 2 Device configuration 8 5 3 Check Status 11 6 Sensor functions 12 6 1 Equipment vibration data acquisition 12 6 2 Vibration index report 13 6 3 Power button...

Страница 3: ...ginal waveform and feature edge calculation to meet the needs of multiple use scenarios The product complies with IEC 60079 intrinsically safe explosion proof standard the explosion proof mark is Ex i...

Страница 4: ...ZAIoT VTC01 4 2 Appearance and size Unit mm ZAIoT VTC01 Sensor Appearance...

Страница 5: ...t 400g With battery Battery capacity 9600mAh Replaceable Battery life 3 years default setting Wireless Specification Wireless Protocol ZETA H Frequency band Sub GHz adjustable according to local regul...

Страница 6: ...installation The sensor supports three types of mounting magnet adhesive and M5 bolt with the threaded connection mounting being preferred If the equipment does not have the conditions for drilling a...

Страница 7: ...ZAIoT VTC01 7 when shipped Check the status of the terminal on the platform to see if it is online...

Страница 8: ...orm platform address https platforms zifisense com network login 5 2 Device configuration After logging in go to the Network Device ZETA MS page and click the Add button to add a new device And add th...

Страница 9: ...T VTC01 9 Select from the left menu Network Device ZETA MS Add The red asterisk is a required item after filling in press OK to add the device Check the device apply Device Control Settings as shown b...

Страница 10: ...chinery Acquisition of raw vibration data according to the configuration period and wirelessly backhauled through ZETA H protocol The sampling frequency and the number of spectral lines can be configu...

Страница 11: ...ce in the list When the device is powered on the online status will change from offline to online and the startup time registration time and heartbeat time are updated If the data is underlined you ca...

Страница 12: ...parameter query Version number query 6 Sensor functions 6 1 Equipment vibration data acquisition Acquisition of equipment triaxial vibration data Remote configuration of the reporting period Remote c...

Страница 13: ...6 4 Battery replacement When the platform reports a low battery alarm please replace the battery promptly Replacement procedure Unscrew the four screws securing the terminal housing and open the housi...

Страница 14: ...ZAIoT VTC01 14 terminal is successfully connected If unsuccessful operate the button to restart once...

Страница 15: ...on restart which is the fastest means Check the power level reported on the last platform to see if there is a possibility of low battery Battery power drops badly Collection cycles are too frequent a...

Страница 16: ...atic charging hazard clean only with a damp cloth 2 Only ER26500 lithium thionyl chloride battery produced by EVE Energy Co Ltd is allowed to be used as the power supply Do not charge the battery Do n...

Страница 17: ...n part FCC Statement Any Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part...

Страница 18: ...ZAIoT VTC01 18...

Отзывы: