background image

 
 
 

STW1K 

10630-0710-00

 

page

 

2 / 6 

www.ziehl.de 

  

 
 

Table of contents 

 

1

 

General Notes ......................................................................................................................................... 2

 

2

 

Application and short description ......................................................................................................... 3

 

3

 

Functional overview ............................................................................................................................... 3

 

4

 

Wiring scheme ........................................................................................................................................ 3

 

5

 

Important notes ...................................................................................................................................... 3

 

6

 

Detailed description ............................................................................................................................... 4

 

7

 

Assembly ................................................................................................................................................ 4

 

8

 

Start-up ................................................................................................................................................... 4

 

9

 

Trouble – shooting and remedies .......................................................................................................... 5

 

10

 

Technical data ........................................................................................................................................ 5

 

11

 

Design K .................................................................................................................................................. 6

 

12

 

Disposal .................................................................................................................................................. 6

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1  General Notes 

 
Compliance with the following instructions is mandatory to ensure the functionality and safety of the product. 
If the following instructions given especially but not limited for general safety, transport, storage, mounting, 
operating conditions, commissioning and disposal / recycling are not observed, the product may not operate 
safely and may cause a hazard to the life and limb of users and third parties.  
 
Deviations from the following requirements may therefore lead both to the loss of the statutory material defect 
liability rights and to the liability of the buyer for the product that has become unsafe due to the deviation from 
the specifications. 
 

 

 

Содержание STW1K

Страница 1: ...uring Transducers Grid and Plant Protection Operating Manual STW1K updated 2022 07 13 Um For more information and help about this product please scan the QR Code or choose the following link STW1K Operating manual Quick guide Datasheet Connection diagram CAD Data Firmwareupdates FAQ Videos about installation and settings Certificates STW1K 10630 0710 00 page 1 6 www ziehl de AC Current Sensing Rel...

Страница 2: ...ensure the functionality and safety of the product If the following instructions given especially but not limited for general safety transport storage mounting operating conditions commissioning and disposal recycling are not observed the product may not operate safely and may cause a hazard to the life and limb of users and third parties Deviations from the following requirements may therefore le...

Страница 3: ...g for a central extraction system in wood processing 3 Functional overview 8 inputs in OR circuit relay on when 1 input is activated response threshold approx 1 A connection of current sensor S1 power supply for S1 required switch off delay approx 10 s Inputs that are not required remain open 4 Wiring scheme 5 Important notes DANGER Hazardous voltage Will cause death or serious injury Turn off and...

Страница 4: ...ctor 2 330 Ω resistor increase by a factor 4 120 Ω resistor increase by a factor 10 Due to large tolerances that must be considered we recommend that the best values be determined by trial and error method Length of connecting cables STWA1 H Up to 50 m also much longer are also possible Shielding may be required when laid parallel to power lines 7 Assembly The unit can be mounted as follows mounti...

Страница 5: ... 1 1 x 10 5 switching cycles at 240 V 6 A Durability of mechanical contact 3 x 10 7 switching cycles Short circuit resistance NO Short circuit resistance NC 4 A slow action or LS switch B4 3 15 A slow action Shutdown capability Category AC 15 Ie 3 A Ue 250 V Rated operational current Rated operational voltage DC 13 Ie 2 A Ue 24 V Reduction factor for cos φ 0 3 0 5 Transformer connection Connection...

Страница 6: ... Fine wire with conductor ferrule 1 x 0 14 mm 2 2 5 mm 2 AWG 28 16 Strip length tightening torque 8 mm 0 5 Nm Protection snaps IP40 IP 20 Fastening Snap on mounting on 35 mm mounting rail according to EN 60715 or screw fixing M 4 Mounting position any Weight approx 150 kg Subject to technical changes 11 Design K Dimensions in mm 12 Disposal Disposal should be carried out properly and in an environ...