5.6.2
Forced ventilation installation on top
5.6.2.1
Technical data
Voltage
220 - 240
[V]
Frequency
50 / 60
[Hz]
Power
2 x 20 / 19
[W]
Current
2 x 0.125 / 0.11
[A]
Table 5-6-2-1
5.6.2.2
Connection diagram
Figure 5-6-2-2-01
1 Thermal contact
2 PE optional
6 Start-up
6.1
Operating conditions
"
The elevator machine must be installed in a not free accessible machine room or a closed hoist-
way.
"
Be aware of the protection class speci
fi
ed on the name plate.
"
Do not operate the elevator machine in an explosive atmosphere.
"
Please contact ZIEHL-ABEGG SE in case of orders deviating from the corresponding application
conditions.
6.2
First Start-up
Before
fi
rst-time start-up, check the following:
"
Installation and electrical connection have been properly completed.
"
Safety devices are installed.
"
All leftover installation materials and other foreign materials have been removed.
"
The protective earth is connected.
"
Motor protection correctly connected and operative.
"
Cable entries closed.
"
Mounting, installation position and accessories are o.k.
"
Connection data corresponds to the data on the name plate.
Original operating instructions
ZAtop
–
model series SM250.60B
Start-up
A-TBA20_02-GB 2032 Index 003
Part.-No. 01013399-GB (EU-BD 783)
25/72