RH setpoint
RH setpoint
Setting range: 0...100 %
Factory setting: 75 %
RH pband
Humidity control range
Adapting the control action to the system conditions.
Narrow control range = Short control times
Wide control range = Longer control times and more stable control
Setting range: 0...100 %
Factory setting: 20 %
RH minimum
humidity minimal
Setting range: 0...100 %
Factory setting: 20 %
“
Humidity minimal
”
is greater than setting
“
Humidity maximal
”
RH maximum
humidity maximal
Setting range: 100...0 %
Factory setting: 100 %
Information
A heater is required in the stall for a perfectly working humidity control!
Note!
Due to the in
fl
uence of the humidity control the stall temperature can drop below the temperature
setpoint of the ventilation and the heating may be activated. To avoid too great an in
fl
uence from the
humidity, the
“
maximal humidity cooling
”
can be set in the installation menu. Within the adjustable
range, the humidity control is reduced linearly to
“
0
”
.
Operating Instructions
Fcontrol
–
model series FTET4/6/10AHMQ-L
Settings for operation
L-BAL-E139-GB 2022/03 Index 006
Part.-No.
62/92