4 Installation
4.1 Mounting the motor
Attention!
•
Check the device for damage, e.g. cracks, dents or damage to the electric cables,
before assembly. Start-up is not allowed in the case of transport damage!
•
Mounting is only to be undertaken by trained service personnel. The system
manufacturer or the machine builder and/or the user is responsible that the inherent
installation and security information are harmonized with the valid standard and
guidelines (EN ISO 12100 / 13857).
•
The custom designs must suit the prevailing conditions.
•
During assembly of the fan impellers or other components, no inadmissible pressure
may be applied to the motor bearing.
•
If the motor is used to drive fan impellers or other components, please note the
maximum permissible speeds of the impeller or the component to be driven.
•
The maximum permissible mass of the impeller or the component to be driven is
0.3 kg. Greater masses must be inquired about at ZIEHL-ABEGG and con
fi
rmed in
writing.
•
Tighten the fastenings with the speci
fi
ed torques.
•
The motor must be installed in a housing which has a protection class of at least IP20
and guarantees protection against ultraviolet radiation and electrostatic charge.
•
The motor must be installed so that the motor body cannot be accessed directly by the
end user. This is normally achieved by means of a protective grille, screening or
barriers resulting from the application.
•
The housing must meet the mechanical requirements of the applicable standards and
regulations. Please refer to IEC 60079-0 section 26.4.2.
•
When being used as a fan drive in a potentially explosive area, the fan design must
also meet the applicable explosion protection standard, e.g. distances, material pairs,
etc.
Assembly instructions
ECQ
Installation
L-BAL-F071-GB 1642 Index 001
Part.-No. 00703698-GB
8/17