1 General notes

1.1 Structure of the operating instructions

These operating instructions only apply in conjunction with the mounting/operat-
ing instructions for the device in which this module is installed. The remarks 
concerning safety, installation and connection described there must be followed!
Before installation and start-up, read this manual carefully to ensure correct use!

1.2 Exclusion of liability

Concurrence between the contents of these document and the described software has 
been examined. It is still possible that non-compliances exist. No guarantee is assumed 
for complete conformity.To allow for future developments  given are subject to altera-
tion.We do not accept any liability for possible errors or omissions in the information 
contained in data, illustrations or drawings provided. 
ZIEHL-ABEGG SE is not liable for damage due to misuse, incorrect or improper use.

2 Safety instructions

Information

Mounting, electrical connection, and start-up operation may only be carried out by an 
electrical specialist in accordance with electrotechnical regulations (e.g. EN 50110 or EN 
60204)!

Danger due to electric current

It is generally forbidden to carry out work on electrical live parts. Protection class 
of the device when open is IP00! It is possible to touch hazardous voltages 
directly.

The 5 electrical safety rules must be observed!

The safe isolation from the supply must be checked using a 

two-pole

 voltage 

detector. 

Even after disconnecting the mains voltage, life-threatening charges can appear 
between the protective ground 

PE

 and the mains connection.

Waiting period at least 3 minutes!

Opening the device in which the module is to be installed (fan, inverter) is only allowed 
when the mains power is switched off and after waiting at least three minutes.
Through use of capacitors, danger of death exists even after switching off the device 
through directly touching the energized parts or due to parts that have become energized 
due to faults.

Operating Instructions 

AM-LON

 

General notes

L-BAL-E166-GB 1610 Index 002

Part.-No. 00163375-GB

3/9

Содержание AM-LON

Страница 1: ...AM LON Part No 349049 Communication module for ECblue fans Operating Instructions L BAL E166 GB 1610 Index 002 Part No 00163375 GB english ...

Страница 2: ... 3 5 Disposal recycling 4 4 Mounting the module 5 5 Electrical installation 6 5 1 Safety precautions 6 5 2 Voltage supply 6 5 3 Communication 6 5 3 1 Connecting at the AM LON Modul 6 5 3 2 Wiring and terminating resistor in the LON network 7 6 Enclosure 8 6 1 Connection diagram 8 6 2 Manufacturer reference 9 6 3 Service information 9 Operating Instructions AM LON L BAL E166 GB 1610 Index 002 Part ...

Страница 3: ... electrical connection and start up operation may only be carried out by an electrical specialist in accordance with electrotechnical regulations e g EN 50110 or EN 60204 Danger due to electric current It is generally forbidden to carry out work on electrical live parts Protection class of the device when open is IP00 It is possible to touch hazardous voltages directly The 5 electrical safety rule...

Страница 4: ...inal packaging materials when transporting the device Avoid shocks and impacts to the device during the transport During manual handling the human lifting and carrying restrictions must be observed and adhered to 3 4 Storage The device must be stored in its original packaging in a dry and weather proof room Avoid exposure to extreme heat and cold Avoid over long storage periods we recommend a maxi...

Страница 5: ...ing This applies regardless of whether the device is already connected to the line Equalize the potential again shortly before installation if the module is not installed immediately after unpacking After unpacking the module check for possible transport damage and insert it in the slot provided Do not touch the connection ECblue Mount the module in the housing with the two enclosed screws permiss...

Страница 6: ...ected to terminals NET_A and NET_B The correct choice of cable is essential for the proper operation of the network Recommended wire types 22AWG twisted pair typical solid an unshilded Remote control line JY St Y 2x2x0 6 Wieland line system gesis con The connection of the LON bus is not polarity sensitive When using cable with more than two strands ensure that two twisted strands only are used for...

Страница 7: ...e for routing reasons then free wiring can be used as an alternative Please note the restrictions on line length Information If any matters are unclear you can send for our technical information sheet Network structure of a LON TIL00_70 It contains information about the topology circuitry and selection of types of cable With free wiring i e no wiring rule is applied a terminating resistor of 50 Ω ...

Страница 8: ...6 1 Connection diagram AM LON ID1 V ID2 MOLN07K0 15 03 2011 LON Service Pin max 5 VDC V LON Service Pin max 5 VDC B A B A Operating Instructions AM LON Enclosure L BAL E166 GB 1610 Index 002 Part No 00163375 GB 8 9 ...

Страница 9: ...for control systems ventilation technology phone 49 0 7940 16 800 Email fan controls service ziehl abegg de Our worldwide contacts are available in our subsidiaries for deliveries outside of Ger many www ziehl abegg com If you make returns for inspections or repairs we need certain information in order to facilitate focused trouble shooting and fast repair Please use our repair tickets for this It...

Отзывы: