ZIEHL-ABEGG Acontrol PXET6Q Скачать руководство пользователя страница 4

1

General notes

Compliance with the following instructions is mandatory to ensure the functionality and safety of the 
product. If the following instructions given especially but not limited for general safety, transport, 
storage, mounting, operating conditions, start-up, maintenance, repair, cleaning and disposal / recy-
cling are not observed, the product may not operate safely and may cause a hazard to the life and 
limb of users and third parties.
Deviations from the following requirements may therefore lead both to the loss of the statutory material 
defect liability rights and to the liability of the buyer for the product that has become unsafe due to the 
deviation from the speci

cations. 

1.1

Structure of the operating instructions

Before installation and start-up, read this manual carefully to ensure correct use!
We emphasize that these operating instructions apply to speci

c units only, and are in no way valid for 

the complete system!
Use these operating instructions to work safely with and on the device. They contain safety instruc-
tions that must be complied with as well as information that is required for failure-free operation of the 
device.
Keep these operating instructions together with the device. It must be ensured that all persons that 
are to work on the device can refer to the operating instructions at any time.
Keep the operating instructions for continued use. They must be passed-on to all successive owners, 
users and 

nal customers.

1.2

Target group

The operating instructions address persons entrusted with planning, installation, start-up, mainte-
nance and servicing, who have the corresponding quali

cations and skills for their job.

1.3

Exclusion of liability

Concurrence between the contents of these operating instructions and the described hardware and 
software in the device has been examined. It is still possible that non-compliances exist; no guarantee 
is assumed for complete conformity. To allow for future developments, construction methods and 
technical data given are subject to alteration. We do not accept any liability for possible errors or 
omissions in the information contained in data, illustrations or drawings provided. 
ZIEHL-ABEGG SE is not liable for damage due to misuse, incorrect use, improper use or as a 
consequence of unauthorized repairs or modi

cations.

1.4

Copyright

These operating instructions contain copyright protected information. The operating instructions may 
be neither completely nor partially photocopied, reproduced, translated or put on data medium without 
previous explicit consent from ZIEHL-ABEGG SE. Infringements are liable for damages. All rights 
reserved, including those that arise through patent issue or registration on a utility model. 

2

Safety instructions

This chapter contains instructions to prevent personal injury and property damage. These instructions 
do not lay claim to completeness. In case of questions and problems, please consult our company 
technicians.

2.1

Intended use

The equipment is to be used solely for the purposes speci

ed and con

rmed in the order.

Any other use above and beyond this is considered not for the intended purpose unless agreed 
otherwise by contract. The manufacturer will not be liable for any damage resulting from this. The 
individual or company using it bears the sole risk.
Reading these operating instructions and complying with all contained instructions - especially the 
safety noti

cations contained therein - are considered part of intended use. To consider is also the 

manual of attached components. Not the manufacturer, rather the operator of the device is liable for 
any personal harm or material damage arising from non-intended use!

Operating Instructions 

Acontrol

 

 model series PXET6Q / PXET10Q

General notes

L-BAL-E016-GB 1925 Index 007

Part.-No. 

4/32

Содержание Acontrol PXET6Q

Страница 1: ...ntrol PXET6Q PXET10Q Multipurpose controller for variable voltage 1 fans Operating Instructions Keep for reference Software version B1061AA from version 1 01 L BAL E016 GB 1925 Index 007 Part No engli...

Страница 2: ...ulture 8 4 5 Temperature in uences during commissioning 8 5 Electrical installation 8 5 1 Safety precautions 8 5 2 EMC compatible installation 9 5 2 1 Motor cable 9 5 2 2 Control cables 9 5 2 3 Harmon...

Страница 3: ...r operation as Temperature controller 20 9 2 2 Example Temperature control Cooling function factory setting 21 9 2 3 Example Temperature control Heating function 21 9 3 Pressure control condensers P C...

Страница 4: ...software in the device has been examined It is still possible that non compliances exist no guarantee is assumed for complete conformity To allow for future developments construction methods and techn...

Страница 5: ...instructions of AEL DLG VdS 2 4 Requirements placed on the personnel due diligence Persons entrusted with the planning installation commissioning and maintenance and servicing in connection with the...

Страница 6: ...use 2 8 Operator s obligation of diligence The contractor or owner must also ensure that the electric systems and equipment are operated and maintained in accordance with electro technical regulations...

Страница 7: ...amage Start up is not allowed in the case of transport damage At a weight greater than 25 kg for men 10 kg for women the device should be lifted out by two persons according to REFA The values may dif...

Страница 8: ...ions Danger due to electric current Work on electric components may only be carried out by trained electricians or by persons instructed in electricity under the supervision of an electrician in accor...

Страница 9: ...ered to with no restrictions Exception for Germany An energy provider follows the technical connection conditions of the TAB2007 in which case the use of phase angle controlled devices up to a rating...

Страница 10: ...or remote control ON OFF enable Attention An outside voltage may never be connected to the terminals TB If a bypass circuit is installed or in the 100 position on devices with a main switch the motor...

Страница 11: ...Controller or PI Controller function for D1 can be selected with DIP 8 5 8 Voltage supply for external devices 24V GND A voltage supply is integrated for external devices e g a sensor max current loa...

Страница 12: ...indicated for line fault blown internal semiconductor fuse broken controller internal voltage supply overheating by the motor thermostats TB connected By sensor failure only in P Control or PI Contro...

Страница 13: ...2 and selected mode For Speed controller 1 01 always without function For the P controller 2 01 3 01 and PI controller 4 01 the DIP 2 switch can be used to select whether the set value setting can be...

Страница 14: ...active at the factory DIP 2 OFF For temperature control 2 01 with passive sensors TF KTY setting range 0 100 26 76 C measuring range of controller For control with active sensors 3 01 4 01 0 10 V 4 2...

Страница 15: ...ns become active partly only after renewed switching on the mains voltage E1 Analog In factory setting 0 10 V 13 03 2012 v_jumper_e1_dip_s1_mode vsd A E1 GND 0 10 V 10 k E1 GND TF TF KTY 3 1 BN GN 24V...

Страница 16: ...the sensor is compared with the nominal value that has been set The output voltage and hence the rotational speed of the connected motor automatically change as a function of the parameter settings T...

Страница 17: ...ith minimum speed cut off DIP 5 ON When the setpoint is reached the modulation is reduced to 0 or to the set value if n min is speci ed For actual value setpoint disconnection takes place from n min t...

Страница 18: ...or external potentiometer DIP 2 OFF factory setting Setting range Output voltage from approx 0 100 of connected line voltage or in range of settings n min up to n max Potentiometer set without functi...

Страница 19: ...two steps DIP2 OFF for setting via external signall Switchover between two steps via external potential free contact possible Step 1 low speed When there is no input signal connected to the input term...

Страница 20: ...5 8 76 0 Scale 0 100 26 76 C for Temperature control with passive sensors TF KTY set 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 C 26 0 20 9 15 8 10 7 5 6 0 5 4 6 9 7 14 8 19 9 25 0...

Страница 21: ...n min 35 n max 85 Idealized principle diagram 9 2 3 Example Temperature control Heating function Val Set n DIP4 ON Temperature sensor type TF Measuring range controller 26 76 C Settings set 50 25 C 10...

Страница 22: ...08 v_pxet_q_skala_mbg30 VSD set 0 10 20 30 40 50 60 70 80 90 100 bar 0 0 3 0 6 0 9 0 12 0 15 0 18 0 21 0 24 0 27 0 30 0 19 07 2011 v_pband_pxet VSD Pband 5 30 Pband Pband Narrow control range Short co...

Страница 23: ...of refrigerant medium table for R507 Pband 10 3 0 bar U Motor 50 100 bar C 50 15 bar 34 28 C 507 Set Pband 10 12 03 2008 v_diagramm_bar_c vsd 18 bar 41 53 C 507 n min 0 n max 100 n min 35 n max 85 Ide...

Страница 24: ...7 54 25 58 41 62 30 65 96 69 41 72 70 75 82 78 81 81 68 84 44 87 09 89 66 R401A C 29 21 6 93 6 40 16 33 24 39 31 26 37 28 42 68 47 59 52 10 56 29 60 22 63 91 67 40 70 72 73 88 76 91 79 81 82 60 85 29...

Страница 25: ...ala_mal1 VSD set 0 10 20 30 40 50 60 70 80 90 100 m s 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 19 07 2011 v_pband_pxet VSD Pband 5 30 Pband Pband Narrow control range Short control times Wide contr...

Страница 26: ...Motor fault Tripping of connected thermostat or break between terminals TB The unit cuts out and does not switch on again Check motor and connection then reset Motor protection 3 energized Terminals 1...

Страница 27: ...230 V 15 10 50 60 Hz 230 V Input resistance for sensor or signal set for the rotational speed for 0 10 V input Ri 100 k for 4 20 mA input Ri 100 Output voltage approx 0 100 of applied mains voltage M...

Страница 28: ...e the rated temperature see following table The average value measured during a 24 h period must be 5 K under the max ambient temperature For installation in a switch cabinet the device s dissipation...

Страница 29: ...usgang Output 0 10 V Imax 10 mA 3 Eingang Input 0 10 V 0 20 mA 4 20 mA TF KTY 4 1 2 5 E1 V mA C 1 Line 1 230 V 50 60 Hz 2 1 Motor with internal thermostats 3 Output 0 10 V Imax 10 mA 4 Input 0 10 V 0...

Страница 30: ...11 3 Dimensions mm PXET6Q PXET10Q Operating Instructions Acontrol model series PXET6Q PXET10Q Enclosure L BAL E016 GB 1925 Index 007 Part No 30 32...

Страница 31: ...5 M mains connection 9 mains voltage 9 maximum control current 9 MBG 30I 21 Minimum space requirement 7 Minimum speed cut off 16 Mode 14 motor feed cable 9 motor noise 9 motor protection unit 9 O Outd...

Страница 32: ...o ziehl abegg de http www ziehl abegg de 11 6 Service information If you have any technical questions while commissioning or regarding malfunctions please contact our technical support for control sys...

Отзывы: