Ziegra ZBE 110 Скачать руководство пользователя страница 3

Start-up

1.   Temperatures:

              

Ambient:

   normal       max.          min.

                                              

ZBE 30 to ZBE 350

20 °C

42 °C

+ 5 °C

ZBE 375

35 °C

45 °C

+ 5 °C

Water:

ZBE 30 to ZBE 350

15 °C

> 5 °C

ZBE 375

25 °C

> 5 °C

2. Installation site

Distance from rear wall at least 10 cm
(ZBE 150-ZBE 375: 20 cm). The ventilation apertures 
of the machine must not be covered. 
Provide sufficient room ventilation.

The ice production capacity may decrease at high
ambient- or water temperature or insufficient 
ventilation of the machine. At low temperatures the 
machine may switch off or even freeze up.

ZBE 30-10        ZBE 70-35         ZBE 110-35
ZBE 150  bis  ZBE 375: 

see specification

3. Water connection:

4.   Electrical connection

The machine operates with normal potable water or

fuses  16 A, slow

fully demineralized (destilled) water.

                

With harder water 

> 14° d.H.: install a water softener.

230V-1-50 Hz

Machine incl. 2 m cable and plug

<

  

  6° d.H.: consult Ziegra

or on request for ZBE 350 und ZBE 375:

If the water is slightly saline, or comes from a well or 

400V-3-50 Hz

Make firm installation to main 

is outside 7,2 - 9,5 pH: consult Ziegra. 

power supply. Provide main switch.
3-phase machines have a 

supplied with m/c:

2 m high-pressure hose an

phase sequence relay.

3/4'' sleeve for water inlet

Other voltage according to order, type plate, wiring

Provide at side:

Water pressure: 1 - 5 bar

diagram.

              

stop valve and strainer
If long supply lines necessary, 
insulate, if possible.

5.   Storage bin:

Wash out thoroughly with warm water.

Melt-water drain

supplied with m/c:

2 m hose, 14 mm dia.

Provide at side:

Mount hose and fasten with clamp.

6.   Start

Ice production starts after app. 2 min.

                            

The drain pipe must be at a lower level than the 
machine outlet. Otherwise the melt water will not
drain off from the storage bin.

7. Machines without bin only:

Fasten tube to the ice discharge by means of clamp.

The ice mus leave the outlet freely and without clogging

Otherwise the freezing unit and gearbox will be overloaded.

Extension of ice discharge tube:
Enlargen diameter, no sharp curbs. Only use tubes with 
smooth inner surface (without edges). 

Ice must slide downwards only, 

not horizontically or upwards.

Further advice in the extra folder "Installation Ice discharge"

2

Содержание ZBE 110

Страница 1: ...quality Miscellaneous 6 Freezing unit 7 Refrigerant and water cicuits 8 wiring diagram attached General installation advice Assembly Instruction Freezing unit Spare parts list Subject to technical modifications Edition 07 8 09 ZIEGRA EISMASCHINEN Germany 30901 Isernhagen www ziegra com Service Tel 49 0511 90244 0 Tel 49 0511 90244 18 Fax 90244 90 Fax 90244 92 ice ziegra com service ziegra com ZBE ...

Страница 2: ...ing auger does not form part of the refrigeration circuit Therefore leakages in the refrigeration system caused by rotating parts cannot occur The ideal ice temperature is 0 5 C Ziegra chip ice has the ideal temperature of 0 5 C It is irregular and crystalline in structure and always stays loose In contrast with other types of ice it can be stored without being sub cooled and never freezes up Zieg...

Страница 3: ...ke firm installation to main is outside 7 2 9 5 pH consult Ziegra power supply Provide main switch 3 phase machines have a supplied with m c 2 m high pressure hose an phase sequence relay 3 4 sleeve for water inlet Other voltage according to order type plate wiring Provide at side Water pressure 1 5 bar diagram stop valve and strainer If long supply lines necessary insulate if possible 5 Storage b...

Страница 4: ...in case of too low water pressure or water shortage Automatic restart when the water supply has been restored 4 Compressor Automatic motor cut out in compressor connecting box 5 High pressure switch The machine is switched off if there is e g excess in the refrigeration system caused by too high ambient temperature or soiled condenser 6 Gear Motor Overload cut out in switch box 7 Automatic water d...

Страница 5: ... ZBE 110 lift grid and take it off All parts getting in contact with ice ZBE 150 ZBE 375 remove lid ice hose into storage and front panel ice discharge interior or exterior Ice storage melt water grid General check Any water leaks melt water drain The machine runs quite ice scoop Small parts After being thorougly cleaned Every 2 5 years can also be given into dishwasher check cylinder bearing Scal...

Страница 6: ... ambient temperature too high Machine must not be placed in the sun or too warm ambience Improve ventilation condensor soiled Clean with brush or compressed air ventilator motor defective Check replace Machine does not work General electrical faults Absence of current Check socket and fuses Intermittent contact Check electrical connections also in control panel Water pressure switch defective repl...

Страница 7: ...runs in intervals see above refrigeration unit stopped If Ice maker is connected no sufficient refrigerant check the cooling system of the to a central refrigeration unit Suction pressure too low central refrigeration unit Machine runs in intervals pressure fluctuation Data must comply to the ZIEGRA prescription If not at hand ask Ziegra Rumbling or loud squeaking Air bubble in pipe between water ...

Страница 8: ...ber and the freezing unit into a container o Connect a hose of appr 80 cm with funnel at the water inlet of the freezing unit o Mix cleaning agent with hot water 1 3 bottle agent in 3 4 litre water of appr 50 C o Fill the freezing unit with cleaning agent up to the ice discharge level o Allow the cleaner to react for 10 15 minutes A maximum of 30 minutes must not be exceeded The cleaner first remo...