47
FAULTS AND TROUBLESHOOTING
8.
HYDRAULICS
Fault
Cause
Remedy
Page
Cornheader front at-
tachment
Insufficient quantities of
hydraulic oil
Refill oil
38
Insufficient lift force
Additional lift cylinder required
18
Hydraulic function of
the picker does not
function
Hydraulic connections have
no throughflow
Check the connections / couplings /
screw connections
21
Insufficient pressure of the
hydraulic system
Check the pressure, increase if per-
missible
CH
handbook
Insufficient quantities of
hydraulic oil
Refill oil
38
DRIVE
Fault
Cause
Remedy
Page
Drive is activated but
the picker does not
rotate
Drive shaft
Check the drive shaft
20
The drive shaft coupler
does not engage
Locking impossible, check the cou-
pling halves for full engagement
20
The coupling does not en-
gage
Check the alignment, make the shifter
piece passable
21
The picker remains
stationary during op-
eration
The V-belt is not tightened
Check the drive
CH
handbook
Overload
Adapt the working speed
CROSS AUGER
Fault
Cause
Remedy
Page
Cross auger remains
stationary
Overload
Reduce the material quantity straw
content too high
Friction coupling engages
Remove foreign objects, check the
scraper
29
Drive
Check the chain and coupling
28
Original combine harvester,
splash guard fitted in front of
the feeder channel
Remove the splash guard
Auger ejects corn cob
from the machine
Position and number of
conveyor plates
Alter to fit the conditions
Insufficient feed rate
Increase the feed