background image

V

ersion 2.0, 07/07 

Operating 
temperature 

-35 to 8

0℃(-31to 176℉)

 

Battery type 

3.6V 

lithium(1/2AA)(SAFT 

LS14250,  Tadiran  TL-5101  or 
equivalent) 

Battery life 

1  year(typ.)  depending  on  logging 
rate,  ambient  temperature  &  use  of 
Alarm LEDs 

Dimensions/We
ight 

101x25x23mm  (4x1x.9”)/  172g 
(6oz) 

 

 
BATTERY REPLACEMENT 

Only use 3.6V lithium batteries. Before replacing the 
battery,  remove  the  model  from  the  PC.  Follow 
diagrammatic  and  explaination  steps  1  throught  4 
below: 
 
1.

 

With a pointed object(d.g. a samll screwdriver or 
similar),  open  the  casing.  Lever  the  casing  off  in 
the direction of the arrow. 

 
2.

 

Pull the data logger from the casing. 

 
3.

 

Replace/Insert  the  battery  into  the  battery 
compartment  observing  the  right  polarity.  The 
two  displays  briefly  light  up  for  control 
purposes(alternationg, green, yellow, green). 

Содержание ZI-9630

Страница 1: ...ZI 9630 Humidity Temperature USB Data logger www zicotech com REC ALM...

Страница 2: ...USB Interface User Selectable Alarm Analysis software Multi mode to start logging Long battery life Selectable measuring cycle 2s 5s 10s 30s 1m 5m 10m 30m 1hr 2hr 3hr 6hr 12hr 24hr DISCRIPTION 1 Prote...

Страница 3: ...s OFF Logging not active Or Low Battery Start logging Replace battery and download the data REC ALM One green flash every 10 sec Logging no alarm condition Green double flash every 10 sec Delayed star...

Страница 4: ...lost Replace battery and download data REC ALM Yellow single flash every 10 sec Logging low alarm for TEMP Yellow double flash every 10 sec Logging high alarm for TEMP Yellow single flash every 60 sec...

Страница 5: ...rations will be disabled automatically NOTE Logging automatically stops when the battery weakens logged data will be retained The supplied software is required to restart logging and to download logge...

Страница 6: ...5 Accuracy 40 to 60 3 0 Temperature Overall Range 40 to 70 40 to 158 Accuracy 40 to 10 and 40 to 70 2 Accuracy 10 to 40 1 Accuracy 40 to 14 and 104 to 158 3 6 Accuracy 14 to 104 1 8 Dew point Tempera...

Страница 7: ...nly use 3 6V lithium batteries Before replacing the battery remove the model from the PC Follow diagrammatic and explaination steps 1 throught 4 below 1 With a pointed object d g a samll screwdriver o...

Страница 8: ...data logger is ready for programing NOTE Leaving the model plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost WARNING Handle lithium batteries care...

Страница 9: ...al conditions which can lead to inaccurate readings To recondition the internal sensor please follow the procedure below Bake the Logger at 80 C 176 F at 5 RH for 36 hours followed by 20 30 C 70 90 F...

Отзывы: