Zibro SRE 168 E Скачать руководство пользователя страница 6

Check the removable tank fuel gauge 

G

while filling the tank (Fig. E). Stop 

filling by loosening the switch button on top of the pump (turn anti-clock-

wise), once the gauge indicates that the tank is full. Never overfill the tank, 

especially not when the fuel is very cold (fuel expands when it heats up).

Let the remaining fuel in the pump flow back into the jerrycan and carefully 

remove the pump. Carefully screw the fuel cap back on the tank using the 

fuel cap cover. After use, re-store the cover at the rear of the heater. Clean 

off any spilled fuel.

Check whether the fuel cap is straight and tightened properly. Reinstall the 

removable tank in the heater (cap down). Close the lid.

C

SETTING THE CLOCK

It is only possible to set the correct time, when the heater is connected to the

mains and not burning. Use the adjustment keys 

O

to set the time. First press

either of the two keys to switch on the function (the CLOCK light and the

information display 

L

will start blinking). Next, set the hours using the key on the

left (

N

hour) and the minutes using the key on the right (

M

min.). Press once to

increase the value by one step. When you hold down the key, the value will

continue going up, until you release the key again. After approximately 10

seconds the blinking will stop and the setting will be locked. 5 minutes after

switching off the heater, the information on the display will disappear and the

heater will automatically switch into the stand-by position. 

When the heater has been unplugged for more than 10 minutes (or after a

power failure), the time needs to be set again. 

D

IGNITING THE HEATER

When used for the first time, a new heater may give out a smell for a short while.

You should therefore provide extra ventilation.

Always ignite the heater with the 

button 

M

. Never use matches or a cigarette

lighter.  Just press the 

button 

M

to ignite the heater. The button will start

blinking, indicating that the ignition procedure has started. This will take a short

while. Once the heater is burning, the 

button 

will remain lit (red). The

information display 

L

will show two numbers. The light next to them indicates

that these numbers refer to the temperatures (Fig. G). The actual room

temperature is indicated below ROOM, while the temperature setting is indicated

below SET. The latter can be changed with the adjustment keys (refer to Section E).

Prior to igniting the heater, always check for sufficient fuel in the removable tank.

E

SETTING THE REQUIRED TEMPERATURE

The temperature setting can only be adjusted, when the heater is burning. Use the

adjustment keys 

O

to adjust the temperature. First press either of the two keys to

switch on the function (the TEMP light next to the information display 

will start

blinking). Next, adjust the temperature using the key on the right (

M

min.) to set

the temperature to a higher setting and the key on the left (

N

hour) to lower the

temperature. Press once to increase the value one step. After approximately 10

seconds the light will stop blinking and the setting will be locked (Fig. G).

8

7

6

4

54

E

empty

full

G: The required

temperature on the left,

the measured

temperature on the

right.

F: When the CLOCK

indicator light stops

blinking, the setting has

been locked to the

indicated value.

Содержание SRE 168 E

Страница 1: ...2 6 5 4 u 1 FIN MANUEL D UTILISATION GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO KÄYTTÖOHJE OPERATING MANUAL ISTRUZIONI D USO BRUKSANVISNING GEBRUIKSAANWIJZING BRUKSANVISNING 2 10 20 30 40 50 60 70 80 90 ...

Страница 2: ...se read these Directions for Use first to ensure maximum lifetime for your Zibro Your heater comes with a 24 month manufacturer s warranty on all defects in material or workmanship We wish you much warmth and comfort with your Zibro Yours sincerely PVG International b v Customer Service Department 1 READ THE DIRECTIONS FOR USE FIRST 2 IN CASE OF ANY DOUBT CONTACT YOUR ZIBRO DEALER 3 BEFORE YOU STA...

Страница 3: ...ning fuel in the heater MAIN COMPONENTS Front plate Grid Base plate Lid for removable tank Operation panel Handle Removable tank Air filter Vent filter Thermostat Plug cord Information display key Childproof lock Adjustment keys time and temperature TIMER SAVE key Indicator lights EXTENSION Connection weektimer Air quality control system A B C 4 E F G H I J K L M N O P Q R S T E E E E E E E E E E ...

Страница 4: ... your Zibro in cellars or other underground areas THE RIGHT FUEL Only use Class C1 paraffin fuel in accordance with BS2869 Part 2 or equivalent Your Zibro heater has been designed for use with high quality water free pure paraffin oil such as Zibro Extra or Zibro Kristal Only fuels of this kind will ensure clean and proper burning Lower quality fuel may result in E increased possibility of malfunc...

Страница 5: ... O refer to Section C Your Zibro is now ready for use B FILLING FUEL Do not fill the removable tank in the living room but in a more suitable place there can always be some spillage Follow the procedure below Make sure that the heater is switched off Open the lid 4 and lift the removable tank 7 out of the heater Fig B Note Some drops may leak from the tank Put down the removable tank cap pointing ...

Страница 6: ...inutes or after a power failure the time needs to be set again D IGNITING THE HEATER When used for the first time a new heater may give out a smell for a short while You should therefore provide extra ventilation Always ignite the heater with the button M Never use matches or a cigarette lighter Just press the button M to ignite the heater The button will start blinking indicating that the ignitio...

Страница 7: ...approximately the required temperature at the set time When you want to switch off the heater and ignite it again with the timer all you have to do is press the TIMER key refer to Section G Press the button M once to clear the timer setting If you would like more extensive timer possibilities we advise you to procure the Zibro weektimer This timer is easy to connect with your Zibro Heater see T G ...

Страница 8: ...heater has been burning continuously for two hours at its highest setting the burner will automatically start an autoclean procedure The display will show the autocleaning code cl 05 running back to cl 01 The procedure takes 5 minutes during which the heater will burn at its lowest setting while the burner autocleans When the burner is clean again the heater will automatically switch back to the h...

Страница 9: ...ll take some time after the refill before the heater is completely ready for use again L THE VENT INDICATOR LIGHT When there is insufficient ventilation in the room an intermittent buzzer will be heard approximately once each 30 seconds and the VENT indicator will be lit When this signal is given ensure that the ventilation of the room is improved e g by opening a door or window a little more to a...

Страница 10: ...el When you start re using the heater follow the instructions again starting from section A and as specified O TRANSPORTATION Take the following measures to avoid fuel leakage during the transportation of the heater Let the heater cool down Remove the removable tank G from the heater and remove the fuel filter refer to Section M Fig N Some drops may leak from the filter keep a cloth at hand Store ...

Страница 11: ...nces may induce uncontrollable burning causing flames to break out Should this happen never try to move the heater but always switch off the heater immediately In case of emergency you may use a fire extinguisher but only a type B extinguisher a carbon dioxide or powder extinguisher 10 TIPS FOR SAFE USE 1 Make sure that children are always aware of the presence of a burning heater 2 Do not move th...

Страница 12: ...s produits de combustion Contrôle de la qualité de la combustion absence de CO Endurance Intermittence CONSEILS D UTILISATION ET D ENTRETIEN Se reporter à la notice jointe à l appareil et à la plaque de sécurité sur l appareil Référence et numéro de lot ou de série de l article se reporter au produit Distributed in Europe by PVG International B V P O Box 96 5340 AB OSS Pays Bas Tél 31 0 412 694670...

Страница 13: ...E E E E E E E E E E E E E E E E E E E E E E E E E A E G F D J B C I K H E Q P S N L R M T O ...

Страница 14: ...ce zibro com SUOMI Appliance Finland Oy Piispantilankuja 6C 02240 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com F FI IN N 4 UNITED KINGDOM Scott Brothers Ltd The Old Barn Holly House Estate Cranage Middlewich CW10 9LT UK tel 44 1606 837787 fax 44 1606 837757 email sales scottmail co uk ITALIA PVG Italy SRL Via Niccolò Copernico 5 50051 CASTELFIORENTINO FI tel 39 ...

Отзывы: