background image

4

71

Fig. 6

1.  When connecting extension drain hose, insulate the connecting part of extension drain hose with a

shield pipe, do not let the drain hose slack.

Fig. 7

Connective pipe

2.  For the left-hand and right-hand piping, remove the pipe cover from the side panel. The pipe cover

must be kept as it may be used when relocate the air conditioner to any other place.

Fig. 8

4. Indoor unit installation 

For SC 30xx models

1.

Pass the piping through the hole in the wall.

2. 

Put the upper claw at the back of the indoor unit on the upper hook of the installation plate, move the

indoor unit from side to side to see that it is securely hooked.

3. 

The female half can be easily past through by lifting the indoor unit with a cushioning material bet-

ween the indoor unit and the wall. Get it out after finishing it.

4.  Push the lower part of the indoor unit up on the wall. Then move the indoor unit from side to side, up

and down to check if it is hooked securely.

G

ATTENTION

Always use the highest care when bending the piping. Make sure that the piping always is

bended and not nodded. In case of a nodded pipe: do not attempt to install this nodded pipe as

this is a potential refrigerant leak.

.

.

.

.

.

.

.

. .

.

.

.

.

.

.

.

. .

.

.

. .

.

.. .

.

.

.

.

.

.

. .

.

. .

.

.

.

.

.

.

.

.. .

.

.

. .

.

.

.

.

.

. .

.

. . .

.

.

.

.

.

.

. .

.

.

.

.

.

.

. .

.

.

.. .

.

.

.

.

. .

.

.

.

.

.

. .

.

.

.

.

. .

.

..

.

.

.

.

.

.

.

.

. .

.

.

.

.

.

. .

.

.

.

.

.

.

.

.

.

.

. ..

.

.

.

.

.

.

.

......

..

.

.

.

.. .

43

Pipe holder

Pipe Cover (left)

Left piping

Left back piping

Right back piping

Right piping

Pipe Cover (right)

.

.

.

.

.

.

.

. .

.

.

.

.

.

.

.

. .

.

.

. .

.

.. .

.

.

.

.

.

.

. .

.

. .

.

.

.

.

.

.

.

.. .

.

.

. .

.

.

.

.

.

. .

.

. . .

.

.

.

.

.

.

. .

.

.

.

.

.

.

. .

.

.

.. .

.

.

.

.

. .

.

.

.

.

.

. .

.

.

.

.

. .

.

..

.

.

.

.

.

.

.

.

. .

.

.

.

.

.

. .

.

.

.

.

.

.

.

.

.

.

. ..

.

.

.

.

.

.

.

......

..

.

.

.

.. .

43

Upper Hook

Lower Hook

Cushion

material

.

.

.

.

.

.

.

. .

.

.

.

.

.

.

.

. .

.

.

. .

.

.. .

.

.

.

.

.

.

. .

.

. .

.

.

.

.

.

.

.

.. .

.

.

. .

.

.

.

.

.

. .

.

. . .

.

.

.

.

.

.

. .

.

.

.

.

.

.

. .

.

.

.. .

.

.

.

.

. .

.

.

.

.

.

. .

.

.

.

.

. .

.

..

.

.

.

.

.

.

.

.

. .

.

.

.

.

.

. .

.

.

.

.

.

.

.

.

.

.

. ..

.

.

.

.

.

.

.

......

..

.

.

.

.. .

43

Do not block water flow by a rise.

Do not put the end of drain hose 

into water.

instal_S(C)30xx.qxd  19-07-2010  13:33  Pagina 71

Содержание SC 3050

Страница 1: ...S C 30xx Installation Manual 2 5 3 4 1 INSTALLATIONS HANDBUCH MANUAL DE INSTALACIÓN MANUEL D INSTALLATION INSTALLATION MANUAL INSTALLATIEHANDLEIDING INSTRUKCJA MONTAŅU 2 22 42 62 82 102 ...

Страница 2: ...n nor can it assume any liability in connection with its use The information specifications and parameter are subject to change due to technical modifications or improvement without any prior notice The accurate specifications are presented on the nameplate label Please read this installation manual completely before installing the product When the power cord is damaged replacement work shall be p...

Страница 3: ...xperience and authorisation Improper installation can cause water leakage electrical shock refrigerant leakage or fire Please consult authorized dealer or specialized air conditioner engineer for the installation work Please note faults caused by improper installation is not covered by warranty Unit must be installed in an easily accessible area Any additional cost required to hire special equipme...

Страница 4: ...o connect the indoor and outdoor units securely and attach the wires firmly to the terminal board connecting sections so the stress of the wires is not applied to the sections Incorrect connection and fixing could cause a fire Be sure to use the provided or specified parts for the installation work The use of defective parts could cause an injury due to a fire electric shock the unit falling etc P...

Страница 5: ...ceiling Any variations in pipe length will may require adjustment to refrigerant charge Fig 2 LEFT More than 30 cm BACK More than 30 cm RIGHT More than 60 cm FRONT More than 200 cm More than 60 cm More than 15 cm More than 12 cm More than 12 cm 2 3 m or more G CAUTIONS This equipment must be earthed and installed with an earth leakage breaker It can possibly cause electrical shock if grounding is ...

Страница 6: ...oduces sound when in use this could interfere with local legislation It is the responsibility of the user to check and to make sure the equipment is in full compliance with local legislation Be sure to level the unit GENERAL Ensure the support structure and anchoring method are adequate for the unit location Consult and follow local legislation regarding mounting and installation of air conditione...

Страница 7: ... H Remote controller holder G NOTE Except the above provided parts the other parts needed during installation are to be purchased separately by the buyer of the airconditioner Number Name of Accessories Quantity 1 Installation plate 1 2 Clip Anchor 8 3 Self tapping screw A ST 3 9x25 8 4 Seal 1 5 Drain joint 1 6 Connecting pipe assembly Liquid side Ø 6 35 Not included Gas side Ø 9 53 3 5 kW model Ø...

Страница 8: ...s otherwise stated 133 40 40 270 27 6 70 750 45 250 70 293 920 50 50 40 285 90 Correct orientation of Installation Plate G ATTENTION Copper lines must be insulated independently from each other G ATTENTION This illustration is for explanation and indication purposes only The illustration may be different from the airconditioner you purchased CAUTION Ensure that the space around the left and right ...

Страница 9: ...4 69 S 3025 SC 3025 S 3032 SC 3032 ...

Страница 10: ...wards to outdoor side this will prevent water to come indoors 2 Always use wall hole conduit when drilling metal grid metal plate or the like 3 Connective pipe and drainage installation G Always run the drain hose sloping downward all the way Do not install the drain hose as illustrated below 133 40 40 270 27 6 70 750 45 250 70 293 920 50 50 40 285 90 Wall Indoor Outdoor 5 5 7 mm per 100 mm 4 70 ...

Страница 11: ... that it is securely hooked 3 The female half can be easily past through by lifting the indoor unit with a cushioning material bet ween the indoor unit and the wall Get it out after finishing it 4 Push the lower part of the indoor unit up on the wall Then move the indoor unit from side to side up and down to check if it is hooked securely G ATTENTION Always use the highest care when bending the pi...

Страница 12: ...heck if it is hooked securely See picture 11 Bending the refrigerant piping at the back of the unit needs to be done with the highest care The piping con sists out of cupper When bending the highlighted part more than 1 time the Cupper will start cracking due to a physical process Cracking can cause leakage refrigerant leakage and is not covered by the warranty Fig 11 5 Piping and wrapping Bundle ...

Страница 13: ...men sions in mm WxHxD Mounting dimensions A mm B mm 700x535x235 458 250 685x430x260 460 276 780x540x250 549 276 760x590x285 530 290 845x695x335 560 335 660x540x250 481 276 Strong wind G ATTENTION If need suspending installation the installation bracket should accord with all technical requirements The installation wall should be strong enough or actions to reinforce should be taken The connection ...

Страница 14: ... PIPING CONNECTION G CAUTION For your safety always wear safety eye wear and work gloves when connecting the pipes G ATTENTION All refrigerant work and refrigerant piping should comply with the local legislation standards and codes and should only be done by qualified and skilled people ø85 mm S1825 S1833 S1847 Installation Service Manual www zibro com download 3 03 20 cm 20 cm 20 cm 20 cm G The l...

Страница 15: ...upling to release the male coupling half from the female half Step 5 To seal and protect from dust reinstall the protective cap and plug REFRIGERANT PIPING CONNECTION for S 30xx models Align the centre of the pipes Sufficiently tighten the flare nut with fingers and then tighten it with a spanner and torque wrench as shown see fig 19 and fig 20 Select the correct tightening torque shown table 1 in...

Страница 16: ... and codes and be installed by qua lified and skilled people 7 An individual branch circuit and single receptacle used only for this air conditioner must be available See the following table for suggested fuse specifications G NOTE The supply voltage should be consistent with the rated voltage of the air conditioner Model Power supply Input Rated Current Switch Fuse Power cord size 2 4 kW 230V 50H...

Страница 17: ...g 22 4 Wrap those cables not connected with terminals with insulation tapes so that they will not touch any electrical components 5 Fit the power cord clamp Fig 21 Fig 22 Connect the cable to the outdoor unit for SC 30xx models 1 The connection cables of indoor and outdoor units have been connected to the terminals on the con trol board except the grounding wire Y G only white plug connectors expo...

Страница 18: ...ng in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation Check them and make sure that they are all tightly fastened If they are loose it could cause burn out of the wires Check specification of power source Confirm that supplied electrical capacity is sufficient See to that the starting voltage is maintaine...

Страница 19: ...lectrical safety check Perform the electric safe check after completing installation 1 Insulated resistance The insulated resistance must be more than 2MΩ 2 Grounding work After finishing grounding work measure the grounding resistance by visual detection and grounding resistance tester Make sure the grounding resistance is less than 4 Ω 3 Electrical leakage check performing during test running Du...

Страница 20: ...k sound 2 Press the manual control button twice until the operating indicator lights up the unit will operate on Forced Cool mode 3 Check if all the functions works well during test running Especially check whether the drainage of indoor unit is smooth or not 4 Press the manual switch button again after finishing the test running The operating indicator turns dark and the unit stops operating and ...

Страница 21: ...4 81 ...

Страница 22: ...oppure contattate il Centro Assistenza Clienti per conoscere il numero di telefono consultate www zibro com N Hvis du trenger informasjon eller hvis du har et problem med produktet kan du gå til nettsidene www zibro com Alternativt kan du kontakte med PVG forbrukertjeneste telefonnummeret i www zibro com NL Als u informatie nodig hebt of als u een probleem hebt bezoek dan de onze website www zibro...

Отзывы: